background image

1

Instruction Manual

PRINTED 0911 

322835-000

KEEP THIS MANUAL IN THE POCKET ON HEATER FOR FUTURE REFERENCE 

WHENEVER MAINTENANCE ADJUSTMENT OR SERVICE IS REQUIRED.

NOT FOR USE IN MANUFACTURED (MOBILE) HOMES

ALL TECHNICAL AND WARRANTY QUESTIONS:

 SHOULD BE DIRECTED TO THE LOCAL DEALER FROM WHOM THE WATER HEATER WAS PURCHASED. 

IF YOU ARE UNSUCCESSFUL, CONTACT RESIDENTIAL TECHNICAL ASSISTANCE AT 1-615-889-8900 OR VIA E-MAIL AT [email protected].

 

COMMERCIAL GAS WATER HEATERS

• 

For Your Safety

 •

AN ODORANT IS ADDED TO THE GAS USED 

BY THIS WATER HEATER.

C3 Technology

®

 Gas Water Heaters meet the new 

ANSI Z21.10.1 standard that deals with the accidental or 
unintended ignition of flammable vapors, such as those 
emitted by gasoline.

GAMA certification applies 
to all residential gas water 
heaters with capacities of 20 
to 100 gallons with input rating 
of 75,000 BTU/Hr. or less.

®

300 Maddox Simpson Parkway

Lebanon, TN 37090

Phone: 615-889-8900 • Fax: 615-547-1000

Technical Services email: [email protected]

www.lochinvar.com

LOW LEAD

COMPLIANT

Содержание COMMERCIAL GAS WATER HEATERS

Страница 1: ...IL AT 2TECH LOCHINVAR COM COMMERCIAL GAS WATER HEATERS For Your Safety AN ODORANT IS ADDED TO THE GAS USED BY THIS WATER HEATER C3 Technology Gas Water Heaters meet the new ANSI Z21 10 1 standard that...

Страница 2: ...it relates to the installation of gas fired water heaters The qualified installer must also be familiar with the design features and use of flammable vapor ignition resistant water heaters and have a...

Страница 3: ...3 GENERAL SAFETY...

Страница 4: ...follow the safety rules the water heater will not operate properly It could cause DEATH SERIOUS BODILY INJURY AND OR PROPERTY DAMAGE This manual contains instructions for the installation operation an...

Страница 5: ...Y LOCAL CODES FIGURE 1 J Drip Leg Sediment Trap K Inner Door L Outer door M Union N Inlet Water Shut off Valve O Cold Water Inlet P Inlet Dip Tube Q Temperature Pressure Relief Valve R Rating Plate S...

Страница 6: ...others These include the elderly children the infirm or physically mentally handicapped If anyone using hot water in your home fits into one of these groups or if there is a local code or state law re...

Страница 7: ...larm or turn off the incoming water to the water heater when leakage is detected Sensors mounted in the drain pan that turn off the water supply to the entire home when water is detected in the drain...

Страница 8: ...al injury or death Do not apply insulation to the top of the water heater as this will interfere with safe operation of the draft hood Do not cover the outer door thermostat or temperature pressure re...

Страница 9: ...1 cm2 kW of total input rating of all equipment in the enclosure see Figure 9 Alternatively a single permanent opening may be used when communicating directly with the outdoors or with spaces that fre...

Страница 10: ...uires water for space heating at temperatures higher than required for domestic water purposes a tempering valve must be installed Please refer to Figure 2 for suggested piping arrangement Water suppl...

Страница 11: ...ctly into the fitting of the water heater designed for the relief valve Position the valve downward and provide tubing so that any discharge will exit only within 6 inches 153 mm above or at any dista...

Страница 12: ...ion For replacement heater installations where using pre existing venting venting must be inspected for obstructions and if deterioration is present venting must be replaced To insure proper venting o...

Страница 13: ...ing all gas appliances is used also turn off the gas at each appliance Leave all gas appliances shut off until the water heater installation is complete A gas line of sufficient size must be run to th...

Страница 14: ...trol valve of the water heater can be accomplished by either of the two methods shown in Figures 13 and 14 A sediment trap shall be installed as close to the inlet of the water heater as practical at...

Страница 15: ...burner It can be located by looking through the glass view port while pressing the piezo ignitor button several times Look for a spark at the pilot location see Figure D 9 Once the pilot has been foun...

Страница 16: ...htubs showers sink etc HOTTER WATER CAN SCALD Water heaters are intended to produce hot water Water heated to a temperature which will satisfy space heating clothes washing dish washing and other sani...

Страница 17: ...urner area during heating and cooling periods and should be considered normal See Condensation in this section OPERATIONAL CONDITIONS SMELLY WATER In each water heater there is installed at least one...

Страница 18: ...able However over a period of time a flooded water heater will create dangerous conditions which can cause DEATH SERIOUS BODILY INJURY OR PROPERTY DAMAGE Contact a qualified installer or service agenc...

Страница 19: ...s to completely reset and continues to release water immediately close the cold water inlet to the water heater follow the draining instructions and replace the temperature pressure relief valve with...

Страница 20: ...d drip onto the burner or run on the floor This is common at the time of start up after installation and when incoming water is cold I Water in the water heater bottom or on the floor may be from cond...

Страница 21: ...ional 26 Instruction Manual 27A Nipple with Heat Trap 27B Secondary Anode with Heat Trap Not Shown Now that you have purchased this water heater should a need ever exist for repair parts or service si...

Страница 22: ...nctions Thermocouple TCO malfunction Replace pilot assembly High ambient room temperature Contact a service agency to determine cause BURNER WILL NOT Dirty or clogged air intake screen Clean and reins...

Страница 23: ...23 NOTES...

Страница 24: ...24 300 Maddox Simpson Parkway Lebanon TN 37090 Phone 615 889 8900 Fax 615 547 1000 Technical Services email 2tech lochinvar com www lochinvar com Copyright 2011 Lochinvar LLC All rights reserved...