9
Switch Ring
Condition of Vacuum Activated
(Air sound comes out)
Condition of Vacuum Inactivated
(Click sound comes out and air stops)
Click sound
4.
HOW TO RIVET
Following is the procedure for riveting:
(1) Drill a prepared hole (0.1 to 0.2mm larger than
the flange diameter of the rivet) in the material
to be riveted.
(2) Turn the switch ring of vacuum device to ON to
activate the device.
•
The vacuum device is activated. You can
hear the vacuum noise.
Crimping operation is possible
even without vacuum activation.
However, the next crimping
operation must be done only
after the cut shafts are evacuated.
(3) Insert a rivet shaft into the Nosepiece of the
riveter.
Rivet is not dropped because
it is vacuumed up.
(4) Insert the rivet flange into the work piece hole.
(5) Press the flange collar onto the material and
pull the trigger.
•
The flange is crimped.
(6) When the trigger is released, the shaft is
automatically evacuated in the tank unit.
The Next crimping operation
must be done only after the
cut shaft is evacuated.
4. How to Rivet