5
■
Do not attempt to modify the tool at any rate.
Modification or remodeling
may lead to malfunction, accident or injury.
Any modification made by the customer will void the warranty.
■
When you handle oil or grease, obtain the material safety data sheet (MSDS) from the
supplier, and follow the described instructions.
1.3 SAFETY
VALVE
This tool incorporates a “safety valve” that blows off air to indicate the abnormality when too
much air is supplied to the riveter.
Pressure: 0.49 to 0.59 MPa (5 to 6 kg/cm
2
)
Blow off air pressure: 0.64MPa(6.5kg/cm
2
)
Procedure in case that the valve blows off:
Appropriate air
(1) Stop using the tool immediately, and stop the air supply.
Safety valve cannot be reset without stopping air supply.
(2) Setup the air pressure to the range between 0.49 and 0.59 MPa (5 to 6 kg/ cm
2
).
(3) Supply air again and confirm that the safety valve does not blow off.
Safety valve must not be removed or disassembled.
Safety valve is an especially important safety device. If
it is accidentally loosened or damaged, consult with the
store you purchased the tool or Lobtex Co, Ltd.
•
Do not use the tool without resetting safety valve
after it blows off. It may cause damage of the tool.
•
If safety valve still blows off after adjusting air
pressure, stop using the tool and consult with a
sales office of Lobtex Co, Ltd.
1. Safety
1. Safety
1. Safety
1. Safety