Prameter
Description
Priority
You can change priority value, A value used to identify the root
bridge. The bridge with the lowest value has the highest priority and is
selected as the root. Enter a number 1 through 65535.
Max Age
You can change Max Age value, The number of seconds a bridge
waits without receiving Spanning-Tree Protocol configuration
messages before attempting a reconfiguration. Enter a number 6
through 40.
Hello
Time
You can change Hello time value, the number of seconds between
the transmission of Spanning-Tree Protocol configuration messages.
Enter a number 1 through 10.
Forward
Delay
time
You can change forward delay time, The number of seconds a port
waits before changing from its Spanning-Tree Protocol learning and
listening states to the forwarding state. Enter a number 4 through 30.
3. The following parameter can be configured on each port , click
set Apply button to modify .