26
6.4
Output Adjustment
Once the pump has been primed, an appropriate output adjust-
ment
MUST
be made. Pump output should be calculated and
adjustments made accordingly.
6.5
Total Pump Output
Calculate the total output of the pump as follows:
PUMP OUTPUT
=
MAX PUMP OUTPUT
x
% SPEED
x
% STROKE
Example: P151-392SI
Use MAX Output (from dataplate on bottom center of pump
control panel) = 24 GPD (24 gallons per day).
If the pump is set at 60% speed and 70% stroke length, the ap-
proximate pump output is:
24.0
x
0.60
x
0.70 = 10.08 GPD (gallons per day). Divide by 24
(hours in one day) to calculate in gallons per hour.
Ifpumpisnotequippedwithspeedadjustment,calculateby
Max
Pump Output
x
% Stroke
only.