Figure II

How to connect the gel pads:

Each gel pad is pre-fixed with a cord-socket and protected by 
a transparent film (Figure I). Attach the gel pads to the 
output cables and insert into the output socket (Figure II). 
Remove the layer of film and place that side of the gel pad 
to the skin, positioning the gel pads on the area of pain. 
Press to ensure adhesion. Please read section ‘Program 
Selection and Gel Pad Positioning’ (pages 19-20) carefully to 
understand where to place the gel pads.

Caution: 

Affix the gel pads so that they do not overlap one 

another and are approximately 4-6 inches apart. Be sure not to 
move the gel pads to another part of your body without turning 
off the power first.

Once the gel pads are attached, the TENS Digital Pain Reliever 
is ready to be switched on.

Please note:

• Never stick the gel pads to each other
• Keep the gel pads clean and do not expose to heat or direct sunlight
• If the gel pads do not adhere to your body or are dirty, wipe with a damp, lint free     
cloth or replace with new ones
• Do not clean the pad or adhesive gels with any chemical
• Place the gel pads on intact skin only. Do not place on cuts or damaged skin
• The TENS Digital Pain Reliever should only be used on one person at a time
• Replace the transparent film on the gel pads when not in use
• When the gel pads need replacing, new gel pads and cables are available at your  

  

local Lloydspharmacy or from www.lloydspharmacy.com. Please replace the output     
cable with the new one supplied

IMPORTANT NOTE: When removing the gel pads from the skin, peel off from one corner 
of the gel pad. DO NOT pull the cord-socket or output cable to remove.

Using your TENS Digital Pain Reliever

Using your TENS Digital Pain Reliever

Содержание TENS LTS2

Страница 1: ...TENS Digital Pain Reliever User Manual Model LTS2 Replacement Gel Pads Available accessories Last revised 15 08 12 V22...

Страница 2: ...s a safe drug free device which helps to ease aches and pains TENS stands for Transcutaneous Electrical Nerve Stimulation and is recognised as a safe method of easing pain TENS is now regularly recomm...

Страница 3: ...TENS interrupts these pain signals Secondly TENS stimulates the body s production of endorphins its own natural painkillers What conditions can TENS help relieve TENS provides pain relief for a numbe...

Страница 4: ...therapy time setting for 30 minutes Touch control buttons and large LCD display making the unit user friendly Simple to use Lightweight and portable 2 gel pads Can also be used as a massager to help r...

Страница 5: ...apist Is it safe to use TENS Digital Pain Reliever The TENS Digital Pain Reliever is a medical device that has been subject to stringent testing It is safe to use for most people with the following ex...

Страница 6: ...gel pads on the cervical vertebrae muscle Do not use on a wet body Do not use on stomach muscles within 90 minutes of eating Please stop using the TENS Digital Pain Reliever immediately if you notice...

Страница 7: ...not affect the timer which will continue to count down from 30 minutes What can I treat The TENS Digital Pain Reliever can treat many different types of pain On pages 19 20 are diagrams of where to p...

Страница 8: ...ever is ready to be switched on Please note Never stick the gel pads to each other Keep the gel pads clean and do not expose to heat or direct sunlight If the gel pads do not adhere to your body or ar...

Страница 9: ...gram indicator will move to Repeat this process to select up to P6 Starting the treatment and setting the intensity To start the treatment press the Increase intensity button which starts at intensity...

Страница 10: ...rent program setting will be saved automatically Figure VI Caution When you have finished using the TENS Digital Pain Reliever please ensure that it is turned off and remove the gel pads Replace the t...

Страница 11: ...ting modes Place the gel pads on the leg Program 3 Back Continuous and burst Place the gel pads to the left and right of the painful area on the lower back waist WARNING DO NOT PLACE THE GEL PADS ON T...

Страница 12: ...LTS 2 Pow er supp ly DC3 0V 2xAA A batte ries Outp ut 0 45 V at 500 ohm load Man ufac turer Shen zhen Don gdix in Tech nolo gy Co Ltd Shan ghai Inter natio nal Hold ing Corp Gmb H Euro pe Eiffe stra e...

Страница 13: ...attach the gel pads correctly Are the gel pads dirty Clean the gel pads with a damp lint free cloth or replace with new gel pads Is the intensity too weak Use a higher intensity level Problem Check p...

Страница 14: ...pose them to direct sunlight Keep the gel pads clean Troubleshooting Problem Check points Possible solution Stimulation stops during therapy Have the gel pads come off the skin Turn off the TENS Digit...

Страница 15: ...and out of the reach of children Store the TENS Digital Pain Reliever in a cool well ventilated place Do not expose the gel pads to direct sunlight and protect them against dirt and moisture Never pla...

Страница 16: ...s Notified body T V Rheinland 0197 Equipment capable of delivering output values in excess of 10mA r m s or 10V r m s averaged over any period of 5 seconds 0197 Shanghai International Holding Corp Gmb...

Отзывы: