background image

9

10

• Cancer patients, people with diabetes or epilepsy should seek medical advice from
  their consultant, doctor or Lloydspharmacy pharmacist before use
• Keep the TENS Digital Pain Reliever out of the reach of children

• Do not use the TENS Digital Pain Reliever with an electrocardiograph meter (ECG) or 
  any other medical apparatus
• Do not use the TENS Digital Pain Reliever with any topically applied creams or 
  ointments
• Do not use on scarred areas following surgery for at least 10 months after the  

 

  operation
• Do not use on or around an area of the body with skin disease, damage or inflammation
• Do not place the gel pads on the head, face, heart, chest area, eyes, oral cavity, sexual  
  organs or onto the spine or bones. 

PLEASE NOTE, BEFORE USING THE NECK PROGRAM,  

  REFER TO PAGE 20 FOR POSITIONING OF THE GEL PADS. When using on the neck     
  area, do not place the gel pads on the spine and do not use on the sides of the neck or   
  the throat (i.e. do not apply over thyroid or carotid sinus region of the neck). Place    
  the gel pads on the cervical vertebrae muscle.

• Do not use on a wet body
• Do not use on stomach muscles within 90 minutes of eating

Please stop using the TENS Digital Pain Reliever immediately if you notice any 
reddening of the skin, if you feel any discomfort or feel unwell (seek medical advice). 
Improper use of the TENS Digital Pain Reliever can lead to harm and damage. For safe 
use of the TENS Digital Pain Reliever, please note the following safety instructions:

• The TENS Digital Pain Reliever must be turned off before moving the gels pads to 
  different parts of the body
• Do not use the TENS Digital Pain Reliever in the bathroom or in any other area of 
  high humidity as this may cause an uncomfortable intense stimulation
• Do not use the TENS Digital Pain Reliever whilst driving or operating any other  

   

  mechanical equipment
• Do not use the TENS Digital Pain Reliever whilst sleeping
• Avoid contact of the gel pads with anything made of metal, such as belts or necklaces
• The TENS Digital Pain Reliever has no AP or APG protection;
 

AP: Flammable anaesthetic proof mixtures with air

 

APG: Flammable anaesthetic proof mixtures with oxygen or nitrous oxide

General Warnings and Safety

General Warnings and Safety

Содержание TENS LTS2

Страница 1: ...TENS Digital Pain Reliever User Manual Model LTS2 Replacement Gel Pads Available accessories Last revised 15 08 12 V22...

Страница 2: ...s a safe drug free device which helps to ease aches and pains TENS stands for Transcutaneous Electrical Nerve Stimulation and is recognised as a safe method of easing pain TENS is now regularly recomm...

Страница 3: ...TENS interrupts these pain signals Secondly TENS stimulates the body s production of endorphins its own natural painkillers What conditions can TENS help relieve TENS provides pain relief for a numbe...

Страница 4: ...therapy time setting for 30 minutes Touch control buttons and large LCD display making the unit user friendly Simple to use Lightweight and portable 2 gel pads Can also be used as a massager to help r...

Страница 5: ...apist Is it safe to use TENS Digital Pain Reliever The TENS Digital Pain Reliever is a medical device that has been subject to stringent testing It is safe to use for most people with the following ex...

Страница 6: ...gel pads on the cervical vertebrae muscle Do not use on a wet body Do not use on stomach muscles within 90 minutes of eating Please stop using the TENS Digital Pain Reliever immediately if you notice...

Страница 7: ...not affect the timer which will continue to count down from 30 minutes What can I treat The TENS Digital Pain Reliever can treat many different types of pain On pages 19 20 are diagrams of where to p...

Страница 8: ...ever is ready to be switched on Please note Never stick the gel pads to each other Keep the gel pads clean and do not expose to heat or direct sunlight If the gel pads do not adhere to your body or ar...

Страница 9: ...gram indicator will move to Repeat this process to select up to P6 Starting the treatment and setting the intensity To start the treatment press the Increase intensity button which starts at intensity...

Страница 10: ...rent program setting will be saved automatically Figure VI Caution When you have finished using the TENS Digital Pain Reliever please ensure that it is turned off and remove the gel pads Replace the t...

Страница 11: ...ting modes Place the gel pads on the leg Program 3 Back Continuous and burst Place the gel pads to the left and right of the painful area on the lower back waist WARNING DO NOT PLACE THE GEL PADS ON T...

Страница 12: ...LTS 2 Pow er supp ly DC3 0V 2xAA A batte ries Outp ut 0 45 V at 500 ohm load Man ufac turer Shen zhen Don gdix in Tech nolo gy Co Ltd Shan ghai Inter natio nal Hold ing Corp Gmb H Euro pe Eiffe stra e...

Страница 13: ...attach the gel pads correctly Are the gel pads dirty Clean the gel pads with a damp lint free cloth or replace with new gel pads Is the intensity too weak Use a higher intensity level Problem Check p...

Страница 14: ...pose them to direct sunlight Keep the gel pads clean Troubleshooting Problem Check points Possible solution Stimulation stops during therapy Have the gel pads come off the skin Turn off the TENS Digit...

Страница 15: ...and out of the reach of children Store the TENS Digital Pain Reliever in a cool well ventilated place Do not expose the gel pads to direct sunlight and protect them against dirt and moisture Never pla...

Страница 16: ...s Notified body T V Rheinland 0197 Equipment capable of delivering output values in excess of 10mA r m s or 10V r m s averaged over any period of 5 seconds 0197 Shanghai International Holding Corp Gmb...

Отзывы: