LK Wired Room Control NC.

Valve exercise program

The connection box has a program to automati-
cally operate the actuators (and manifold valves) 
daily to prevent seizure.

Pump connection

The connection box is equipped with an integra-
ted volt-free pump relay. The circulation pump 
stops when all actuators are closed.

The pump restarts when any thermostat calls for 
heat. There will be a slight delay with starting 
and stopping. The valve exercise program will 
also activate the pump.

Timers, programmers etc.

Important!

If a timer, programmer or other switch is to be 
used they must be connected to the pump relay, 
refer to wiring diagram below. DO NOT switch 
the live on and off to the LK Connection Box, 
which must be kept permanently live.

Design

LK Wired Room Control NC is used where nor-
mally closed (NC) actuators are preferred. A set 
is LK Connection Box NC, LK Room Thermostat 
NC and LK Actuator NC.

Room thermostats control the temperature in 
each zone (e.g. room) via a signal through the 
wire connection to the LK Connection Box NC 
positioned next to the manifold. The manifold ac-
tuators are signalled via the connection box.

Settings/requirements

All distribution fl ows must be adjusted according 
to the installation guide for the unit. The heat set-
tings for the control unit are regulated according 
to the requirements of the heat system and the cli-
mate zone. A control zone consists of 1 LK Room 
Thermostat NC that can control one or more un-
der fl oor heating areas each equipped with an ac-
tuator. A maximum of 5 LK Actuators NC can be 
connected to 1 LK Room Thermostat NC. 

LK Connection Box NC, 230/24 V AC

LK Connection Box NC.

The LK Connection Box NC comes equipped with 
an integrated 230/24 V AC transformer. The box 
is used for connecting and powering the LK Room 
Thermostat NC and LK Actuator NC. The box 
should be situated close to the manifold to avoid 
extending the actuator cables. Up to 8 LK Room 
Thermostats NC may be connected to the box and 
up to 5 LK Actuators NC to each control zone, ho-
wever the overall total number of actuators per 
box must not exceed 12. Mark the zones that con-
trol the rooms on the unit. This can be done most 
conveniently on the attached labels. Each control 
zone is equipped with an LED that indicates when 
the room thermostat requests heat.

LK Wired Room Control NC

EN.33.C.28.0904

Assembly instructions | LK Wired Room Control NC

Содержание Wired Room Control NC

Страница 1: ...ators are signalled via the connection box Settings requirements All distribution flows must be adjusted according to the installation guide for the unit The heat set tings for the control unit are regulated according to the requirements of the heat system and the cli mate zone A control zone consists of 1 LK Room Thermostat NC that can control one or more un der floor heating areas each equipped ...

Страница 2: ...ure is to be ad justed Remote switching The LK Control is a complete unit for outdoor tem perature dependent flow temperature control and adapted for LK s shunt programs If LK Control is used then the volt free pump relay of LK Connec tion box can be connected to LK Control connec tions M and H1 By connecting LK Connection box to the LK Control gives the function that when all actuators on the man...

Страница 3: ...d is connected to the room thermostat as instructed above Floor heating in secondary spaced boarding Place a conduit right between two heat distribu tion plates attach the conduit on the edge of the secondary spaced boarding using a clip for con duits Take into consideration that the placement is at a representative point for the area that is going to be adjusted The external sensor is slip ped in...

Страница 4: ...ong sides of the floor heating installation facing the nearest short end Place the conduit at the short end between two heating pipes and end it approx 2 meters in Seal the end of the conduit with tape or similar to pre vent concrete from getting into the conduit The external sensor is slipped into the conduit before pouring the concrete and is connected to the room thermostat as instructed above ...

Страница 5: ...ectric connections LK Connection Box NC L N zone 2 zone 5 1 4 zone 4 2 1 1 4 zone 1 6 2 4 2 1 7 4 1 zone 2 2 4 zone 1 2 3 zone 2 1 8 4 1 zone 4 4 2 200 mAT 4 A pot free 200 mAt 4 A pot free N L N L zone1 2 4 1 230 V 24 V 40 VA Transformer 98927 2 1 4 ZONE 1 ZONE 2 ZONE 2 ZONE 1 2 1 98927 2 1 4 1 2 1 7 2 3 4 5 6 7 9 11 10 8 Sample connections for a zone Terminal 1 9 on the room thermostat is connec...

Страница 6: ...6 English Wiring with LK Shunt LK Zone Valve and Time Switch if req d LK Connection Box with LK Shunt and LK 2 port Zone Valve 10 Mar 06 EN 33 C 28 0904 Assembly instructions LK Wired Room Control NC ...

Отзывы: