1.3. There are two different ways to mount the wall-

box on, select 1.3.1 or 1.3.2. Always try to assemble 

the wallbox so that the shank is as short as possible, 

this facilitates any replacement of the pipe. 

1.3.1 Fasten the wallbox with the supplied screws.

The wallbox should always be attached against the 

nogging piece, stud or Wet-Room-Wall 2012 (Safe 

Water-wall). When assembling from the front or 

the back, use the four shorter screws. When assem-

bling at the side of a stud or upwards against a 

nogging piece, use the two longer screws. Proceed 

to step 1.4.

1.3.2 Start by mounting LK Universal Pipe 

according to step 1.4 and follow the installa-

tion instructions to step 1.10. Assemble the 

wallbox from the front or back with the four 

shorter screws. When assembling at the side 

of a stud or upwards against a nogging piece, 

use the two longer screws. The wallbox should  

always be attached against the nogging piece, stud 

or Wet-Room-Wall 2012 (Safe Waterwall). Then 

follow the instructions from point 1.11.

NOTE!

The wallbox may never be attached only in 

plaster.

1.4. Adjust the length of LK Universal Pipe by 

cutting it perpendicular with a pipe cutter. Cut 

the conduit another 30 mm for the 16 mm wall box 

and about 40 mm for the 20 mm wall box than the 

media tube is.

1.5. For both LK PE-X and LK PAL Universal Pipes 

must ben deburred inside to prevent damage or 

displacement of the O-rings, which will inevitably 

result in a leaking joint. After deburring, the pipes 

must be cleaned from any shavings.

LK Wallbox UNI Push AX

1.1. Check that all the parts on the wallbox are 

whole prior to assembly. If any part is damaged, 

it must be replaced.

1.2. Drill a hole of diameter 54 mm.

The wallbox can be fastened in many different 

ways:

When two wall boxes are to be installed on a 

wooden stud, 

LK 

W

allbox UNI Push Clamp

 

(Article no. 188 11 04) can be used.

Содержание Wallbox UNI Push AX16 V2

Страница 1: ...assembled on a wall with at least 45 mm studs both in the back and the front edge of the wall depending on the method of construction The wallbox can also be assembled on the side of a stud Screws fo...

Страница 2: ...of a stud or upwards against a nogging piece use the two longer screws The wallbox should always be attached against the nogging piece stud or Wet Room Wall 2012 Safe Waterwall Then follow the instru...

Страница 3: ...pipe and 23 mm on 20 mm pipe The yardstick at LK Smart Tool Push AX RSK 188 25 49 will facilitate it 1 7 Loosen the sleeve coupling and pull out the clip on the 16 mm wall box and on the 20 mm wall b...

Страница 4: ...yer contractor is responsible for the sealing layer s adhesive properties in accordance with the industry rules If the wall cladding is of vinyl covering the sealing layer contractor should be respons...

Страница 5: ...8 06 45 for 16 mm or 188 06 46 for 20 mm or LK SmartTool AX Article no 188 25 49 must be used If the same pipe needs to be reassem bled the pipe ends should be checked so that the coupling s grab ring...

Страница 6: ...1 Cut the wall support to the required length see instructions in the table below 3 2 Fold the upper mounting ear and turn in the lower mounting ear see instructions in the table below 1 5 4 3 2 Cutti...

Страница 7: ...on the wall support but there are no collars for this assembly 4 1 Attach each wallbox to the plate with four of the included system screws as shown above 4 2 The stud must be jacked out 8 mm deep on...

Страница 8: ...mbled The length of the connection coupling should be adjusted so that approximately 10 mm of the pipe thread is exposed when the cover plate is tigh tened against the wall The thread joint against th...