LK Floor Heating | Assembly Instructions | LK Room Temperature Control ICS-RF8

1

EN.33.C.104.1012

LK Room Temperature Control ICS-RF8

 

Design

LK Room Temperature Control ICS-RF8 is a wireless control system designed for LK Floor Heating. LK ICS-
RF8 consists of LK Room Thermostats ICS-RF, an LK Receiver unit ICS RF8 and LK Actuators.

Function

Room thermostats regulate the temperature of each room (zone) via wireless signal transmission to the receiving
control unit. The actuators for each room/zone are controlled by the receiver unit.
The system has several "smart features" such as adaptive weekly programming, holiday functions, the ability
to connect external sensors, external temperature set back via GSM switches, and more. For further information,
please see the 

In-depth description for LK ICS-RF8

.

The system benefits from:

Содержание ICS-RF8

Страница 1: ...F8 and LK Actuators Function Room thermostats regulate the temperature of each room zone via wireless signal transmission to the receiving control unit The actuators for each room zone are controlled by the receiver unit The system has several smart features such as adaptive weekly programming holiday functions the ability to connect external sensors external temperature set back via GSM switches ...

Страница 2: ...adio link is placed outside the cabinet This is easily done with LK Antenna Cable ICS accessories 2 Detach back plate from thermostat by pushing central catch at the bottom of the back plate use screw driver pen or similar Refer to illustration below to open the thermostat Fix thermostat back plates to internal walls approximately 1 5 m above the floor Take care to orientate correctly see arrow on...

Страница 3: ... L key in the receiver unit once to finish the sequence NOTE If necessary the thermostat and the receiver unit can be restored to factory settings See instructions under the heading Reset NOTE If the installation consists of several receivers which are controlling a single pump please read section titled BUS first NOTE Please read the section Checking Signal Strength before starting the system Qui...

Страница 4: ...ng on to provide a desired temperature at a desired time Holiday function When on vacation the temperature of the heating system can be lowered for the duration this is easily done from any thermostat in the system by activating the built in holiday mode LK ICS then keeps track of how many days the system should have a lower temperature and makes sure that the house is again warmed on return from ...

Страница 5: ...old cabinet it is recommended that the radio link should be fixed outside the cabinet Use accessory LK Antenna Cable ICS for simplicity Description of inputs outputs features Description of the program keys illus 1 4 Remove the receiver unit cover the following keys are displayed U key used if the unit s software needs updating separate instructions accompany any software update 1 A key used in co...

Страница 6: ... channel If a regulated zone requires multiple actuators ICS thermostats can be easily set for more than one channel actuator output Please see the Quick Guide LK Actuators are opened once every 24 hrs to prevent the manifold valves from sticking in the closed position essential long term maintenance Power supply illus 7 The device is connected to 230 V AC Fuse illus 8 Beneath the high voltage lid...

Страница 7: ...r connecting the pump Relay for heat source illus 10 Boilers heat sources can be controlled via the heat source relay The relay is located under the lid of high voltage side of the receiver unit NOTE the relay contact is potential free volt free which means that the boiler relay contacts must be powered from an external source and NOT from the receiver unit The boiler heat source will fire approxi...

Страница 8: ...ted to the actuators thermostats BUS and cables for remote control BUS illus 12 Where multiple receiver units are required to control a single pump or single heat source three core cable is connected to the receiver in parallel via the BUS input terminal Please refer to detailed instructions at the end of this instruction Switch NO NC function illus 13 The receiver can be switched to operate actua...

Страница 9: ...justment setting of the Thermostat ICS RF MEM input illus 15 The receiver is equipped with a MEM port that is used primarily when there is to be a system log maintained Measurement data is sent to LK ICS MEM Stick once per minute With the help of measurement data and LK ICS Analyzer software the installer can easily verify analyze the installation 1 Insert the LK ICS MEM Stick into the MEM port Pl...

Страница 10: ...er the temperature at night using a weekly program By default the program starts stops when the programmed start stop times occur Additionally the thermostat s adaptive control can be activated so that the system is self learning The thermostat calculates when the heating should start so that the correct temperature is reached at the desired time Temperature increases are affected by the adaptive ...

Страница 11: ...Instructions LK Room Temperature Control ICS RF8 11 EN 33 C 104 1012 Description of the keys and their functions Left arrow decrease value 1 Mode confirm or access the menus 2 Right arrow increase value 3 Description of display ...

Страница 12: ...rength should be checked so that all thermostats are located within broadcasting area Check signal strength as follows 1 Press Mode until flashes confirm using Mode 2 Press the right arrow until RFST radio signal strenght appears in the display confirm using Mode Allow the unit stabilise for approximately five minutes 3 Read the value The device will automatically return to normal view after 30 mi...

Страница 13: ...emperature can be set up as follows below The system can also adjust the start time so that the correct temperature is reached at the right time with the adaptive function activated self learning By default the weekly program is not activated upon delivery Weekly program activate The weekly program is activated as follows 1 Press Mode until flashes confirm using Mode 2 Press right arrow until WKPG...

Страница 14: ...n Mode WK01 start time comfort days1 7 days choose the time with the left right arrow confirm with Mode WK02 stop time comfort start time eco days 1 7 select the time with the left right arrow confirm with Mode WK03 stop time eco start time comfort days 6 7 select the time with the left right arrow confirm with Mode WK04 stop time comfort start time eco days 6 7 select the time with the left right...

Страница 15: ...ds to return to the weekly program Weekly program disconnect the program constantly If you wish you can disconnect the weekly program constantly for any thermostat The weekly program is disconnected permanently as follows 1 Increase decrease the temperature by using the key 2 Press Mode once when the temperature is flashing 3 Symbol for constantly disconnected weekly programs appear on the display...

Страница 16: ... thermostat was running prior to the holiday function commenced NOTE Observe that the countdown starts from the moment the activation occurs which means that the next day at the same time of the initial activation a day has disappeared Holiday function disable disconnect The function is deactivated from any thermostat as follows 1 Press Mode once 2 Select OFF with left arrow confirm with Mode 3 Th...

Страница 17: ...duction The setback temperature is preset to 12 C The temperature can be changed for individual thermostats as follows 1 Press Mode until flashes confirm with Mode 2 Press the right arrow until SET Setback is shown in the display confirm with Mode 3 Select temperature with the left right arrow confirm with Mode Repeat the above for other thermostats in the system External sensors connection of an ...

Страница 18: ...re Control ICS RF8 18 EN 33 C 104 1012 1 Press Mode until flashes confirm with Mode 2 Press the right arrow until SENM Sensor Mode is shown in display confirm with Mode 3 The display shows SEN and the icon on the left flashes Select from the following modes ...

Страница 19: ...ng Mode the unit shows MAX flashing and is set to maximum temperature Set MAX temperature using the left right arrow confirm with Mode 3 Thermometer and MIN flashes room temperature with the floor at minimum limitation Confirm with Mode the unit switches to MIN flashing and is set to minimum temperature Set minimum temperature using the left right arrow confirm with Mode 4 Heating icon flashes flo...

Страница 20: ...nnection instructions to the room thermostats are given above Floor heating in cross battening Fix conduit 2 metres between ally heat distribution plates using suitable pipe clips to the cross battening consider the location for the sensor carefully as it must be representative of the whole floor The external sensor is slipped into the conduit before laying the floor Connection instructions to the...

Страница 21: ...as a battery icon that shows the battery status The battery should be replaced when the icon only shows one segment Battery replacement is performed as follows 1 Remove the thermostat from the wall by gently pushing the securing plate with a screwdriver while at the same time pulling the thermostat from the back plate the push lock is positioned on the underside of the thermostat 2 Replace the bat...

Страница 22: ...that the networks start and end is specified Place the termination jumper found left side of receiver marked T as follows 1 The networks first point corresponds to the receiver unit that is located first in the network This unit should have its radio link connected Remove the termination jumper from this receiver unit 2 The network s second endpoint corresponds to the receiver unit that is last in...

Страница 23: ... thermostat until is shown in the display 4 The receiver unit s L LED switches to yellow and selectable channels are lit up green 5 Select channels by pressing the desired channel key the selected channel flashes green 6 Confirm by pressing Mode once on the thermostat the thermostat switches to normal view Note that the receiver unit s system number appears in the thermostat display 7 Repeat steps...

Страница 24: ... power is turned on again 03 Total current of actuator outputs too high The device disconnects the actuator outputs When the total power of the output is less than critical value the outputs are automatically reset 04 Adaption of thermostat failure NOTE No fault code displayed Try to reset the thermostat 06 Incorrect Ohm value when external sensor floor sensor is connected Check the connection of ...

Страница 25: ...etween the LK Room Thermostat ICS RF and the LK Receiver unit ICS RF The repeater consists of a radio link with receivers and transmitters A transformer that plugs into a 230V outlet comes with the repeater The repeater is placed between the outer thermostat and receiver Mount the repeater so that the antenna is vertical The set up may contain up to 4 sets of repeaters Adaptation of LK Repeater IC...

Страница 26: ...ermostats Resetting of LK Thermostat ICS RF If necessary the thermostat can be reset 1 Press the left arrow and right arrow keys for at least 5 seconds 2 DEFA text flashes on the display confirm with Mode 3 RUR text appears in the display 4 Remove the battery for at least 5 seconds 5 The unit is now emptied of any information and is ready for new adaptation Resetting of LK Repeater ICS If necessar...

Страница 27: ... Aerial cable is 10 m Comments Totally trouble free operation cannot always be guaranteed with the technology available today that allows free use of EU authorised frequency bands interference from other sources is possible Therefore each installation should be tested individually Manufacturer set thermostat Setting Unit Min Max Factory settings Holiday value Days 1 90 1 Setback temperature C 8 40...

Страница 28: ... Thermostat ICS Article number 2417302 2417303 2417304 Setting range 8 40 C Supply voltage 3 x1 5 V Battery life 2 years Radio frequency Self modulation technique Radio frequency 868 Mhz Dimensions 100 x 100 x 20 Protection class IP20 Operating temperature 1 C 50 C Storage temperature 20 C 70 C Maximum humidity during storage No condensation Article name LK Receiver Unit ICS RF8 Article number 241...

Страница 29: ...requency 868 Mhz Dimensions 120 x 35 x 30 Protection class IP20 Operating temperature 1 C 50 C Storage temperature 20 C 70 C Maximum humidity during storage No condensation This control equipment can be used in all EU and EFTA countries The manufacturer states that the equipment meets the essential requirements and other relevant requirements from the R TTE Directive 1999 5 EC ...