Power failure

If power failure occurs, no data is lost, all pro-

gramming is saved. When the power returns, it 

may take up to ten minutes before the unit has 

reverted to normal operation. The process can be 

hastened by pressing on the upper black button 

(C) of the room thermostat.

Battery exchange of room thermostat

LK Room Thermostat Cq is delivered with two 

1.5 V batteries (LR03). The batteries have an esti-

mated working life of two years. The signal light 

on the thermostat flashes at 15-second intervals 

when it is time to change the batteries. The bat-

teries should be exchanged within the next few 

days; the batteries are located under the lid of the 

thermostat cover. The thermostat reverts to the 

chosen mode of operation after battery exchange. 

Press on the reset-button of the thermostat to has-

ten return to the chosen mode of operation (but-

ton C), see image under heading ”Programming/

Commissioning”. Uncharged batteries yield a 30 

% heat effect on the receiver unit.

CE-compliance

This regulating equipment can be used in all EU 

and EFTA-countries. The manufacturer hereby 

indicates that the equipment fulfills those basic 

requirements and other relevant requirements 

indicated by directive R&TTE 1999/5/EC. The 

manufacturer’s declaration may be downloaded 

from www.funk868mhz.de 

3. Confirm chosen channel

When the thermostat has ”found” its channel the 

sound signal from Cq1 becomes silent and the in-

dication light on Cq1 shuts off. Confirm by pres-

sing once on the upper black button of the ther-

mostat (C). The LED on the thermostat shuts off 

and the diode on the receiver unit will flash a few 

times. The programming is now complete.

Functional control

Test the connection by turning the knob of the 

thermostat up/down. When the thermostat is at 

the maximum position, the indication light on 

Cq1 should be on and when the thermostat is at 

the minimum position, the indication light of the 

Cq1 should be off.

Fault finding /Operational inter-

ruptions

Problems with signal transmissions

If the signals between the thermostat and receiver 

unit are not transmitting correctly, the signal light 

on the receiver unit will flash. During the ongo-

ing signal interruption, the output of the channel 

concerned will produce a 30% effect. If the recei-

ver unit receives signals from thermostat concer-

ned, the alarm is stopped immediately. 

If the problem remains for more than 10 hours, an 

alarm signal will sound in addition to the signal 

light. The problem can be attended to by pressing 

on the reset button (button C) of the thermostat, 

see heading ”Programming/Commissioning”. If 

the problem returns, the batteries of the thermo-

stat concerned may require changing; see heading 

”Battery Exchange” for more information. If the 

problem returns despite battery exchange, it may 

be necessary to strengthen the signal, which can 

be suitably done with the help of a LK Repeater. 

See more in separate instructions for the LK Re-

peater. 

The controlling devices do not shut off

Check that there is power supplied to the outlet. 

Check the fuse of the transformer. Remove the 

plug before changing the fuse. Change to the same 

type of fuse as is already present, 250 V 6.3 A.

Содержание Cq 1 NC

Страница 1: ... termi nal a total of eight devices can be connected Models LK Wireless Room Temperature Controller Cq NC 1 consists of a LK Room Thermostat Cq transmitter and a LK Receiver Unit Cq 1 a re ceiver device for one channel Also included in the wireless assortment is a re ceiving device for eight channels for more infor mation see separate instructions for LK Receiver Unit Cq 8 The LK Repeater Cq HW si...

Страница 2: ...ly The controlling device moves once a day in order to prevent valves from sticking in a closed posi tion If no valve movement is wanted the function can be disconnected by removing jumper 1 on the thermostat Remove the dial of the thermostat loosen the screws and remove the cover Remove jumper 1 marked BR1 on the circuit board Installation A 230 Volt wall outlet should be available nearby the rec...

Страница 3: ...Confirm by pres sing once on the upper black button of the ther mostat C The LED on the thermostat shuts off and the diode on the receiver unit will flash a few times The programming is now complete Functional control Test the connection by turning the knob of the thermostat up down When the thermostat is at the maximum position the indication light on Cq1 should be on and when the thermostat is a...

Страница 4: ... mm Weight 0 144 kg Capping class IP 40 Max no controlling devices Max 8 pcs Article name LK Room Thermostat Cq n Article no 241 88 50 Polar white 241 88 51 Silver grey Setting area 5 30 C Power supply 2 x 1 5 V 3 V alkaline bat teries LR03 Battery life Approx 2 years Control function PBM optional 2 point Cycle period Approx 10 minutes total on off time Measurement interval Approx 10 minutes Type ...

Отзывы: