The Livezi Connect control system coordinates the operation of the Livezi indoor and outdoor 
units, and zone dampers to provide the finest indoor climate control solution currently 
available.

To turn on the system simply press 

 at any touchpad. In the default auto mode the system 

will begin heating or cooling as required. When all areas are off the conditioning system shuts 
down.

The LCD touchpad allows adjustment of various aspects of your indoor climate. By default 
access to all control functions is available from all LCD touchpads.

Access to some control functions may be limited via hardware settings during installation (Refer to 
section 3.2.3 - Zone Touchpads). In the following pages, functions which may be limited in this 
manner will be indicated with a 

¤

 in the heading. 

6.1 

Touchpad layout 

Active:7
Mode=Aut

Liquid Crystal Display showing Global 

Screen with scrolling system summary.

Adjust setpoint, scroll through options 

and change variables.

Access parameter adjustment. Save 

variables and advance to next field. 

Scroll through available zones

Turn system on and off at Global Screen.

Turn zones on and off at Zone Screens.

Adjust the current time or program.

Access mode selection screen. Functions 

as back button while in edit screens.

Adjust setpoint, scroll through options 

and change variables.

Содержание C-CCT-1210

Страница 1: ...ration ready We talk to anyone iPad Interface SET MODE ZONE CLOCK Activ e 5 Cooli ng SET MODE ZONE CLOCK Active 5 Cooling SET MODE ZONE CLOCK Activ e 5 Cooli ng SET MODE ZONE CLOCK Activ e 5 Cooli ng...

Страница 2: ...to make changes and improvements to any of the products described in this docu ment without prior notice Under no circumstances shall Livezi be responsible for any loss of income or any special incide...

Страница 3: ...Zones 9 4 2 Initial Power On 9 4 3 Set Airflow Profiles 9 4 4 System Configuration 10 5 4 1 Set Cooling Performance 10 5 4 2 Set Heating Performance 10 5 4 3 Set Motor Type 10 5 4 1 Set Minimum Venti...

Страница 4: ...g a Zone Temperature 19 7 6 Naming Zones 19 7 7 Setting the Clock 20 7 8 Setting the System Timer Program 20 7 9 Setting Individual Zone Timer Programs 21 Appendix C Airflow Management 22 D 1 Airflow...

Страница 5: ...hat all electrical connections are secure or warranty will be void Field or installation wiring must be connected as per the connection diagram to ensure the unit performs as it is designed Refer to A...

Страница 6: ...l run on any iOS device iPad Ipod Iphone It takes advantage of the large canvas associated with the iPad to provide an intuitive user interface 3 2 1 Chatterbox HVAC Livezi chatterbox creates a page f...

Страница 7: ...ve 5 Cool ing 4 5 2 3 1 Figure 3 2 3 2 1 Connect Main Processor Module The main processor module is best installed on or near the indoor unit Maintain a minimum distance of 300 mm from sources of EMI...

Страница 8: ...er zones ON OFF OFF OFF My Zone Return Full access Display defaults to this zone when backlighting goes off OFF ON OFF OFF Setpoint Limit Full access with setpoint range limited to 20 25 C for this zo...

Страница 9: ...tailored to suit the individual requirement of the space it controls Zone Profiling includes a maximum open position on the damper and an airflow range 4 3 1 Set Zone Maximum Open Profile Each zone i...

Страница 10: ...e top line 2 Use or to alter the heating delay setting then press SET to save and proceed to the next step 4 4 3 Set Motor Type The Livezi Connect utilises a time proportional damper positioning algor...

Страница 11: ...er the timer setting then press SET to save and exit system configuration 4 5 Final Zone Check 1 Select the global screen and press to turn all zones ON 2 Press or to select the first zone 3 Turn the...

Страница 12: ...fitted and sealed Condensate lines do not rise above the floor level of the unit Condensate lines are properly trapped Ductwork is securely fixed to the unit The unit is slung or mounted on suitable...

Страница 13: ...Access to some control functions may be limited via hardware settings during installation Refer to section 3 2 3 Zone Touchpads In the following pages functions which may be limited in this manner wil...

Страница 14: ...e selection screen 2 Use or to alter the mode 3 Press SET to save and exit 6 4 Selecting the Zone mode The mode of operation for individual zones can be selected from each zone screen of the LCD touch...

Страница 15: ...st the return air target temperature 3 Use or to adjust the set point to the desired level 4 Press SET to save and exit 6 8 Naming a zone Zone names must be eight characters in length A blank characte...

Страница 16: ...ram then press SET 4 Use or to highlight desired program A or B then press SET 5 The top line will scroll Program ALL Zones ram Days sMTWTFs 6 On the bottom line the days of the week are displayed A C...

Страница 17: ...xit at this point If there are valid days the top line will scroll Program start Zone x s tart Z 0 8 4 0 a m 5 Use or to alter the start time to the correct value in 10 minute intervals 6 Press SET to...

Страница 18: ...selection Functions as back button in menu system Select menu options Save variables and advance to next field Turn system or zone on and off LED below is illuminated when system is on Active 7 Mode...

Страница 19: ...equired Tips To accept one of the preset zone names press SET repeatedly to accept each character including any blanks until the controller reverts to the standard display When adding a custom name it...

Страница 20: ...hen press SET 4 Use or to highlight desired program A or B then press SET 5 The top line will scroll Program ALL Zones ram Days sMTWTFs 6 On the bottom line the days of the week are displayed A CAPITA...

Страница 21: ...next day Repeat for each day 4 Press SET after the final day value to enter the Start time screen Note If no days have been selected the configuration routine will exit at this point 5 Use or to alter...

Страница 22: ...t is fully closed and the damper to the other is fully open In this instance the VAV system status is the same regardless of which VAV damper is open Actual system open 50 Example 2 Now consider the c...

Страница 23: ...system In the examples on the previous page the following settings will have the desired effect Example 1 Both zones Airflow profile 200 Nominal system airflow requirement 200 Example 2 Large zone Ai...

Страница 24: ...utdoor coil sensor short circuit Indoor coil sensor open circuit Indoor coil sensor short circuit Fault D3 High Pressure or Low pressure Fault Line 2 scrolls one of the following HP compressor safety...

Страница 25: ...r open circuit Outdoor coil sensor short circuit Indoor coil sensor open circuit Indoor coil sensor short circuit Fault I3 Contact Manufacturer Line 2 scrolls one of the following Contact Manufacturer...

Страница 26: ...34 0 c Outoor coil sensor CompLoad Line1 In 36 0 c Indoor coil sensor Line2 LD 100 Compressor load Defrost Line1 Defrost Line2 Ok or DeIce or DeWater 3 Phase Line1 scrolls L1 Ok L2 Down L3 Down state...