9
GB
Installation / Cleaning and Care / Disposal
Preparation / Installation
Open the connection socket
15
on the rear of
the connection housing
1
.
Pull the protective tube
8
over the mains con-
nection lead
6
.
Connect the connection cable of the light to
the power cord
6
using the terminal block
7
(Fig. B).
Also ensure that the colour connection of the
wires is correct when connecting (L or 2 = black
or brown, N or 1 = blue).
Connect the earth wire (3 = green-yellow) to the
marked earth terminal (Fig. B).
Close the connection socket
15
on the rear of
the connection housing
1
.
Fasten the connection housing
1
with the screws
which are included
5
(Fig. C).
Use a clean, lint-free cloth to insert the lamp.
Insert the bulb
14
GU10, 5 W, into the socket
carefully and tighten it with a ¼ turn in a clock-
wise direction.
Screw the light body
2
to the connection hous-
ing
1
again by tightening the screws
3
clock-
wise (Fig. D).
Check for correct fitting.
Your light is now ready for use (Fig. E).
Reinsert the fuse or switch the circuit breaker
back on.
Replacing lamps (3435-024L /
3436-025L)
Note:
The light / LED module is not replaceable in
models 3433-025L and 3434-024L.
CAUTION! RISK OF ELECTRIC SHOCK!
To replace the lamp, first disconnect the light
from the mains circuit. To do so, remove the fuse
or switch off the circuit breaker in the fuse box
0 position.
Allow the light to cool down completely.
Use a dry, lint-free cloth when replacing a lamp.
3435-024L:
Unscrew the light body
2
from the connection
housing
1
by loosening the screws
3
coun-
ter-clockwise (Fig. A).
Twist the defective lamp
14
anti-clockwise out
of the bulb socket.
Carefully insert a new lamp into the socket and
tighten clockwise.
Check for correct fitting.
Screw the light body
2
to the connection
housing
1
again by tightening the screws
3
clockwise (Fig. D).
3436-025L:
Unscrew the light body
2
from the connection
housing
1
by loosening the screws
3
coun-
ter-clockwise (Fig. A).
Twist the defective lamp
14
with a ¼-turn anti-
clockwise out of the bulb socket.
Insert a new lamp into the socket and tighten it
with a ¼-turn clockwise.
Check for correct fitting.
Screw the light body
2
to the connection
housing
1
again by tightening the screws
3
clockwise (Fig. D).
Reinsert the fuse or switch the circuit breaker
back on.
Cleaning and Care
CAUTION! RISK OF ELECTRIC SHOCK!
Disconnect the light from the mains circuit before
cleaning. To do so, remove the fuse or switch off
the circuit breaker in the fuse box 0 position.
Do not use solvents, petrol, etc. Otherwise the
light will be damaged.
Allow the light to cool down completely.
Only use a dry, lint-free cloth for cleaning.
Reinsert the fuse or switch the circuit breaker
back on.
Disposal
The package and packaging materials
consist entirely of environmentally friendly
materials. They can be disposed of at
your local recycling facility.
Содержание 106745