SAFETY INSTRUCTIONS

Specifications

2

Risk of severe injury or death by electrical shock.

To reduce risk of electrical shock, disconnect power before working on or around the system.

Wire pump system for correct voltage.

Be certain that this pump is connected to a circuit equipped with a ground fault circuit interrupter (GFCI) device if required by 

code. 

Check electrical outlets with a circuit analyzer to ensure power, neutral, and ground wires are properly connected.

Some pumps are supplied with a grounding conductor and grounding-type attachment plug. To reduce risk of electric shock, be 

certain that it is connected only to a properly grounded grounding-type receptacle. Do not remove the third prong from the plug. 

The third prong is to ground the pump to help prevent possible electric shock hazard. 

Some pumps are supplied with lead wires and are intended to be hardwired using a junction box or other approved enclosure. 

The pumps include a grounding connector. To reduce risk of electric shock, be certain that it is properly connected to ground.

In a 230 V direct wire installation, one side of the line going to the pump is always electrically energized, regardless of whether 

the liquid level control switch is open or closed. To avoid hazards when installing or servicing, install a double-pole disconnect 

near the pump installation.

The flexible jacketed cord assembly mounted to the pump must not be modified in any way, with the exception of shortening the 

cord to fit into a control panel. Any splice between the pump and the control panel must be made within a junction box and com

-

ply with the National Electrical Code.

Check local electrical and building codes before installation. The installation must be in accordance with their regulations as well 

as the most recent National Electrical Code (NEC) and the Occupational Safety and Health Act (OSHA).

Do not use the power cord for lifting the pump.

Do not use an extension cord.

The pump should only be used with liquids compatible with pump component materials. If the pump is used with liquids incom

-

patible with the pump components, the liquid can cause failure to the electrical insulation system resulting in electrical shock.

Risk of bodily injury, electric shock, or equipment damage.

This equipment must not be used by children or persons with reduced physical, sensory or mental abilities, or lacking in experi

-

ence and expertise, unless supervised or instructed. Children may not use the equipment, nor may they play with the unit or in 

the immediate vicinity.

Equipment can start automatically. Lockout-Tagout before servicing equipment.

An inoperative or malfunctioning pump could lead to flooding, resulting in personal injury or property damage.

The pump has been evaluated for use with water only. Pump should only be used with liquids compatible with pump component 

materials. If the pump is used with liquids incompatible with the pump components, the liquid can cause failure to the electrical 

insulation system resulting in electrical shock.

Operation of this equipment requires detailed installation and operation instructions provided in this manual. Read entire manual 

before starting installation and operation. End User should receive and retain manual for future use.

Risk of damage to pump or other equipment.

Before installing pump, allow air conditioner to cycle several times, collecting condensate in a separate container to help flush any 

residual oils that may remain in the system. Failure to flush the system can result in damage to the pump and drain line plumbing 

components.

When operating in a gas furnace environment, care must be taken to ensure acidity of condensate does not fall below the average 

pH of 3.4 (to prevent a localized pocket of acid that acts like a battery causing pitting) by routinely cleaning or flushing tank with 

fresh water.

Support pump and piping when assembling and when installed. Failure to do so may cause piping to break, pump to fail, motor 

bearing failures, etc.

Do not install the pump in a manner that will subject it to splashing or spraying.

Periodically inspect pump and system components. Regularly check hoses for weakness or wear, making certain that all connec

-

tions are secure.

Schedule and perform routine maintenance as required and in accordance with the Maintenance section of this manual.

Pump is for indoor use only.

Do not use this pump inside an air plenum.

Содержание VCCA-20ULS

Страница 1: ...nd within Little Giant recommendations may result in electrical shock or fire hazard unsatisfactory performance or equipment failure Know the product s application limitations and potential hazards Readand follow instructions carefully to avoid injury and property damage Do not disassemble or repair unit unless described in this manual Refer to product data plate s for additional precautions opera...

Страница 2: ...nts the liquid can cause failure to the electrical insulation system resulting in electrical shock Risk of bodily injury electric shock or equipment damage This equipment must not be used by children or persons with reduced physical sensory or mental abilities or lacking in experi ence and expertise unless supervised or instructed Children may not use the equipment nor may they play with the unit ...

Страница 3: ... to unit and secure with cable tie not provided Ensure the outlet tube check valve adapter is locked into place by verifying the adapter is rotated clockwise as far as possible and the tab on the adapter is aligned with the closed lock symbol 4 Route outlet tubing straight up not exceeding 75 of total dynamic head capacity of the pump 5 At the top make an inverted U trap directly above the pump at...

Страница 4: ...gh water level activating an external alarm or relay purchased separately Use the following proce dure if an NC configuration is required Disconnect the pump from the power source Remove the pump s motor cover 4 Support the switch and carefully change the lead from the NO terminal to the NC terminal 3 Re install the motor cover Connect the switch leads in series with the low voltage external compo...

Страница 5: ...ct and clean the tank and other components follow these steps 1 Disconnect the pump from the power source 2 Remove tank cover assembly from the tank Remove four screws that secure the cover assembly Carefully lift the cover assembly from the tank and hold level 3 Be sure the floats move freely Clean as neces sary 4 Twist to unlock and remove the check valve and backwash the discharge port into the...

Страница 6: ...peration Outlet flow is blocked Check outlet tubing to ensure that it is not kinked or blocked Clear blocked tubing of slime and debris Clean inlet and outlet piping Pump impeller is not turning Clear any blockage in the impeller housing Defective switch Replace pump Defective motor Replace pump Pump will not shut off Float movement obstruction Remove the tank Check float movement path Remove any ...

Страница 7: ...MAINTENANCE Replacement Parts 7 Replacement Parts Part Number Description 305627001 1 4 Hose Barb Check Valve Assembly 305627002 3 8 Hose Barb Check Valve Assembly ...

Страница 8: ...ric Co Inc Oklahoma City OK 73157 2010 For technical assistance parts or repair please contact 800 701 7894 littlegiant com Form 10000006353ȑȆ Rev 00Ȇ ȅȈ 21 Copyright 2021 Franklin Electric Co Inc All rights reserved ...

Страница 9: ...dimientos ade cuados El hecho de no cumplir con los códigos eléctricos y de plomería nacionales y locales y con las reco mendaciones de Little Giant puede provocar peligros de descarga eléctrica o incendio desempeños insatisfactorios o fallas del equipo Lea y siga las instrucciones cuidadosamente para evitar lesiones y daños a los bienes No desarme ni repare la unidad salvo que esté descrito en es...

Страница 10: ...uno salvo para acortar el cable para adecuarlo al interior del panel de control Todos los empalmes entre la bomba y el panel de control deben realizarse dentro de una caja de conexiones y deben cumplir con el Código Eléctrico Nacional Compruebe los códigos eléctricos y de construcción locales antes de la instalación La instalación debe estar de acuerdo con sus regulaciones así como el National Ele...

Страница 11: ...este esté girado en sentido horario tanto como sea posible y que la lengüeta del adaptador esté alineada con el símbolo de candado cerrado 4 Dirija la tubería de salida hacia arriba sin exceder el 75 de la capacidad de carga dinámica total de la bomba Riesgo de daños a bomba u otros equipos Antes de instalar la bomba permita que el aire acondicionado realice varios ciclos y recolecte el condensado...

Страница 12: ...es eléctricas Conecte el cable de alimentación a una fuente constante de energía que coincida con el voltaje en la placa de identificación de la bomba La bomba se debe conectar o cablear en su propio circuito sin otras salidas o equipos en la línea de circuito No lo conecte a un ventilador ni a un dispositivo que funcione de manera intermitente Los fusibles y el disyuntor deben tener una capacidad...

Страница 13: ...e calefacción refrigeración 2 El instalador puede reconfigurar este interruptor al terminal NC para cerrar un circuito de voltaje bajo en el caso de nivel de agua alto lo que podría activar un relé o una alarma externa que se compran por separado Desconecte la bomba de la fuente de alimentación Retire la cubierta del motor de la bomba 4 Sostenga el interruptor y cuidadosamente cambie el cable cond...

Страница 14: ...tante del interruptor de nivel alto de agua El interruptor debe activarse antes de que el flotante entre en contacto con la tapa del tanque Si está cableado al terminal NO el dispositivo de tratamiento de aire debe apagarse cuando se eleva el flotador Si está cableado al terminal NC el componente externo alarma o relé debe activarse cuan dose eleva el flotador MANTENIMIENTO 1 Desconecte la bomba d...

Страница 15: ...á nivelada Si la bomba no está nivelada no se activará haciendo que el agua se des borde del tanque Coloque la unidad sobre una superficie plana y nivelada Acumulación de residuos o acu mulación sobre el flotante Limpie el flotante Un flotante sucio puede estar demasiado pesado para funcionar correctamente Válvula de retención atascada u obstruida Quite la válvula de retención y revísela para comp...

Страница 16: ...a Revise el desempeño nominal de la bomba Bajo voltaje velocidad dema siado lenta Compruebe si hay una fuente de tensión correcta El impulsor o la tubería de des carga están obstruidos Quite la bomba y límpiela Revise si la tubería tiene sarro o señales de corrosión La bomba se enciende y se apaga permanen temente Fugas en la válvula de retención Quite la válvula de retención y revísela para compr...

Страница 17: ...s recommandations de Little Giant pourrait mener à une électrocution ou un incendie une mauvaise performance ou une défaillance de l équipement Lisez et suivez attentivement les instructions pour éviter toute blessure ou tout dommage matériel Ne démontez pas et ne réparez pas l appareil si ces opérations ne sont pas décrites dans le présent manuel Le non respect des procédures d installation ou d ...

Страница 18: ...e réalisée dans une boîte de jonction en conformité avec le code national de l électricité Faire appel à un électricien agréé Vérifiez les codes locaux d électricité et de bâtiment avant l installation L installation doit être conforme à la réglementation ainsi qu au NEC Code américain de l électricité le plus récent et l OSHA loi sur la santé et la sécurité au travail des États Unis Ne pas soulev...

Страница 19: ...in que possible et que la languette de l adaptateur est alignée au pictogramme de cadenas fermé 4 Acheminez la tubulure de sortie de la pompe vers le haut Ne dépassez pas 75 de la charge hydrau lique gal h de la pompe Risque de dommages à la pompe ou d autres équipements Avant d installer la pompe faire faire plusieurs cycles au climatiseur pour recueillir le condensat dans un contenant séparé afi...

Страница 20: ...électriques Raccordez le cordon d alimentation à une source d alimentation électrique constante qui correspond à la plaque signalétique de la pompe La pompe doit être connectée ou branchée sur son propre circuit sans autre prise ou équipement sur la ligne du circuit Ne le raccordez pas à un ventilateur ou à tout dispositif fonctionnant par intermittence Les fusibles et les disjoncteurs doivent êtr...

Страница 21: ...ou un relais externe vendus séparément Utilisez la procédure suivante si une configuration NC est requise Débranchez l alimentation de la pompe Retirer le couvercle du moteur de la pompe 4 Soutenir l interrupteur et passer soigneusement le fil de connexion supérieur de la borne NO 2 à la borne NC 3 Réinstaller soigneusement le couvercle du moteur de la pompe Connecter les fils de connexion de l in...

Страница 22: ...e réservoir et les autres composants suivez ces étapes 1 Débranchez l alimentation de la pompe 2 Retirez l ensemble de capot du réservoir Retirer les quatre vis fixant l assemblage au réservoir Soulever cet assemblage avec précaution au dessus du réservoir et le maintenir à niveau 3 S assurer que le mouvement des flotteurs reste libre Nettoyer au besoin 4 Tournez pour déverrouiller et retirer la s...

Страница 23: ...rtie est bloqué Contrôlez la tuyauterie de sortie afin de vous assurer qu elle n est pas coudée ou obstruée Nettoyez la boue et les débris de tout tuyau obstrué Nettoyez la tuyauterie d entrée et de sortie La roue de la pompe ne tourne pas Nettoyez toute obstruction dans le boîtier de la roue Interrupteur défectueux Remplacez la pompe Moteur défectueux Remplacez la pompe La pompe ne s éteint pas O...

Страница 24: ...Franklin Electric Co Inc Tous droits réservés Pièces de rechange La pompe tourne en continu Fuite de la soupape antiretour Retirez la soupape antiretour et vérifiez qu elle fonctionne correctement Numéro de commande Description 305627001 L ensemble de l adaptateur de clapet antiretour cannelé de 1 4 po 305627002 L ensemble de l adaptateur de clapet antiretour cannelé de 3 8 po Problème Causes prob...

Отзывы: