Little Giant OPWG SERIES Скачать руководство пользователя страница 1

1

INTRODUCTION

EN

This instruction sheet provides you with the information required to safely own and 

operate your Little Giant pump. Retain these instructions for future reference.
The Little Giant pump you have purchased is of the highest quality workmanship 

and material, and has been engineered to give you long and reliable service. 

Little Giant pumps are carefully tested, inspected, and packaged to ensure safe 

delivery and operation. Please examine your pump carefully to ensure that no 

damage occurred during shipment. If damage has occurred, please contact the 

place of purchase. They will assist you in replacement or repair, if required.
READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO 

INSTALL, OPERATE, OR SERVICE YOUR LITTLE GIANT PUMP. KNOW 

THE PUMP’S APPLICATION, LIMITATIONS, AND POTENTIAL HAZARDS. 

PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY 

INFORMATION. FAILURE TO COMPLY WITH THESE INSTRUCTIONS 

COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! 

SAFETY GUIDELINES

Ensure that the pump is disconnected from the power source before attempting 

to service or remove any component.
This pump is not submersible.
Do not handle a pump or pump motor with wet hands or when standing on a wet 

or damp surface, or in water.
This pump is supplied with a grounding conductor and/or grounding-type 

attachment plug. To reduce the risk of electric shock, ensure that it is connected to 

a properly-grounded, grounding-type receptacle.
In any installation where property damage and/or personal injury might result 

from an inoperative or leaking pump due to power outages, discharge line 

blockage, or any other reason, use a backup system and/or alarm.
Support the pump and its piping during assembly and after installation. Failure 

to do so may cause damage to the pump and/or piping.

ELECTRICAL CONNECTIONS

WARNING

This pump must be installed by qualified personnel, following all local electrical 

and safety codes, as well as the National Electrical Code (NEC) and the 

Occupational Safety and Health Act (OSHA).
Check the pump label for proper voltage required. Do not connect the pump to 

any voltage other than that shown.
If your pump is equipped with a 3-prong electrical plug, the third prong grounds 

the pump to prevent possible electrical shock hazard. Do not remove the third 

prong from the plug. A separate branch circuit is recommended. Do not use an 

extension cord when connecting the pump to its power source.
Refer to Table 1 to determine proper voltage. The pumps are pre-configured at 

the factory for 115V operation. If 230V operation is required, refer to the label on 

the motor for directions on wiring the pump. BE SURE OF PROPER ROTATION. 

IMPROPER ROTATION WILL SEVERELY DAMAGE THE PUMP AND VOID THE 

WARRANTY.

MATERIALS OF CONSTRUCTION

Volute ........................................................................... Glass-filled polypropylene
Impeller ....................................................................................Glass-filled Noryl®
Drain plug..................................................................... Glass-filled polypropylene
Bracket ......................................................................... Glass-filled polypropylene
Seal (impeller) ..........................................................................Ceramic & Buna-N 
Seal (shaft) ......................................................................................... Carbon face
O-rings ....................................................................................................... Buna-N
Hardware ......................................................................................... Stainless steel

LEAF BASKET (OPTIONAL)

Little Giant offers an optional leaf basket for use with the OPWG pumps. The 

leaf basket is important for providing filtration to the water in the pond and 

keeping large debris from going into the pump. The leaf basket is a necessity for 

installations where the pump is located above the water source (Figure 3).  The 

leaf basket is ready for assembly with any of the OPWG series pumps.

INSTALLATION

WARNING

PLEASE READ ALL INSTRUCTIONS BEFORE OPERATING THE OUT-OF-POND 
WATER GARDEN PUMP. The Out-Of-Pond Water Garden Pump is not self-priming; 
therefore, if the water source is below the pump, a foot valve must be installed and 
the pump should be primed prior to startup. Do not restrict the intake of the pump. 

Do not pump water with temperatures above 95°F. Pipe used for connecting to the 

intake side of the pump should not be of smaller inside diameter than that of the 

intake thread designation. THIS PUMP IS NOT SUBMERSIBLE.
NOTE: IT IS IMPORTANT TO LOCATE THE PUMP AS CLOSE AS POSSIBLE TO 

THE WATER SOURCE. THIS WILL KEEP THE INTAKE PIPING AT A MINIMUM 

LENGTH. USING LONGER SECTIONS OF PIPE AND ADDITIONAL ELBOWS 

WILL ADD ADDITIONAL FRICTION LOSSES AND COULD AFFECT THE 

PRIMING CAPABILITY AND PERFORMANCE OF THE PUMP.
 1. Determine a suitable, permanent location near the water source (pond, 

skimmer, filter, etc.) to mount the pump. There are 3 installation options 

available for the Out-Of-Pond Water Garden Pump (Figures 2-4).

 2. Mount the motor base on a hard, level foundation for all mounting 

installations. DO NOT install pump below ground level or in a low-lying 

area where flooding could occur. Make sure that the mounting surface has 

adequate drainage so that water will not collect around the pump and motor 

housing. If possible, when installing the pump, place a protective barrier 

over the pump to protect the motor from heavy rainfall, which could damage 

the motor and possibly cause electric shock. This barrier should also allow 

clearance around pump motor for air circulation.

  3. Determine what type of water feature will be used with the pump and 

determine its location in reference to the pump. Perform a preliminary 

layout of the piping and adapters to determine the proper length of the 

pipe sections. Minimize the number of elbows used in the intake and 

discharge lines. This will reduce the friction losses and maximize the pump 

performance. The intake line coming from the water source should be kept 

at a minimum length. Once the layout is determined for the water garden 

pond, begin making the permanent connections for the fittings.

  4. Use only plastic PVC-type fittings on both the pump intake and discharge 

(Table 1). All piping should be 2” PVC or flexible type piping. All threaded 

connections should be sealed with Teflon tape and the slip-fit piping 

connections should be sealed with PVC cement. Use compatible cement 

when connecting PVC piping to PVC adapters or PVC adapters to flexible 

piping. All piping should be supported and arranged for ease of alignment 

to the intake and discharge ports on the pump (or with the optional leaf 

basket). Forcing alignment of the piping to the intake and discharge ports 

on the pump volute can cause damage to the volute/leaf basket.

  5. The Out-Of-Pond Water Garden Pumps are not self-priming. DO NOT RUN 

THE PUMP DRY. A flooded intake is recommended for optimum performance 

because it eliminates the risk of running the pump dry or losing prime. THE 

LEAF BASKET AND ALL HARD PIPING DOWN TO THE FOOT/CHECK 

VALVE MUST BE FILLED WITH WATER BEFORE RUNNING THE PUMP.

  6. For in-line use, install the pump so that the pump head (volute) is flooded 

when the pump is started. That is, the inlet of the pump must be below the 

level of the surface of the liquid being pumped (Figure 1).

  When installing the pump above water level, use a foot valve or check 

valve on the piping leading to the intake of the pump for pumping from the 

water source (pond, skimmer, filter, etc.) The foot/check valve will maintain 

the water in the intake line when the pump is not in operation. Figures 2-4 

outline some typical installations for the Out-of-Pond Water Garden Pumps. 

(See Table 1 for pump intake and discharge sizes.)

  7. For all installations, an adjustable ball/gate valve should be used above the 

discharge of the pump. The ball/gate valve helps control the water flow for 

the water feature being used. When the pump is being serviced, be sure to 

close off the ball/gate valve to prevent back-flowing of the water from the 

waterfall/water feature.

  8. When installing the pump below water level, an additional ball/gate valve 

should be installed in the line ahead of the intake or leaf basket so that water 

flow from the water source can be shut-off for pump maintenance and/or 

cleaning the leaf basket screen. DO NOT USE THIS VALVE TO RESTRICT 

THE PUMP INTAKE.

OPWG SERIES OUT-OF-POND  

WATER GARDEN PUMP

POMPE NON SUBMERSIBLE 

POUR BASSIN DE JARDIN 

SÉRIE OPWG

BOMBA FUERA DE ESTANQUE 

PARA JARDIN ACUÁTICO

Franklin Electric Co., Inc.

Oklahoma City, OK 73127

www.lg-outdoor.com

[email protected]

FIGURE 1

Содержание OPWG SERIES

Страница 1: ...NOT SUBMERSIBLE NOTE IT IS IMPORTANT TO LOCATE THE PUMP AS CLOSE AS POSSIBLE TO THE WATER SOURCE THIS WILL KEEP THE INTAKE PIPING AT A MINIMUM LENGTH USING LONGER SECTIONS OF PIPE AND ADDITIONAL ELBOW...

Страница 2: ...e 4 bolts that attach the bracket to the motor Do not insert screwdriver tip into motor to pry against fan blades for it will damage the fan 6 REPLACING CERAMIC IMPELLER SEAL Go through steps 1 3 Remo...

Страница 3: ...us de la d charge de la pompe Ce robinet sera tr s utile pour contr ler le d bit d eau vers les accessoires de la pompe Quand la pompe est en marche s assurer de fermer le robinet afin d viter un refl...

Страница 4: ...operaci n seguras Examine su unidad cuidadosamente para asegurarse de que no haya ocurrido ning n da o durante el transporte Si se ha presentado alg n da o comun quese con el lugar de compra Deber n d...

Страница 5: ...guras 2 4 muestran algunas instalaciones t picas para las bombas fuera de estanque para jard n acu tico Tabla 2 INSTRUCCIONES DE MANTENIMIENTO REPARACI N ADVERTENCIA Siempre desconecte el cable de ene...

Страница 6: ...ons for leakage and replace if necessary V rifier tous les raccords pour d tecter toute fuite et remplacer si n cessaire Revise todas las conexiones para determinar si hay fugas y de ser necesario ree...

Страница 7: ...WARRANTY THIS WARRANTY SETS FORTH THE COMPANY S SOLE OBLIGATION AND PURCHASER S EXCLUSIVE REMEDY FOR DEFECTIVE PRODUCT Franklin Electric Company Inc and its subsidiaries hereafter the Company warrant...

Страница 8: ...WHICH SUCH LIABILITY IS BASED DAMAGES AS SET FORTH IN THIS PARAGRAPH SHALL BE REASONABLY MITIGATED TO THE EXTENT POSSIBLE THIS PARAGRAPH SHALL ALSO APPLY TO ALL DAMAGES RESULTING FROM CONDITIONS SET...

Страница 9: ...s pouvez avoir d autres droits qui varient selon les lois et r glements applicables Si toute stipulation de cette garantie est interdite par ces lois elle sera nulle et sans effet mais le reste de la...

Страница 10: ...N EL PER ODO DE TIEMPO ESTABLECIDOS ANTERIORMENTE CONSTITUIR EL CUMPLIMIENTO DE TODA LA RESPONSABILIDAD DE LA COMPA A CON EL COMPRADOR YA SEA BASADO EN EL CONTRATO NEGLIGENCIA O DE OTRO MODO LA COMPA...

Страница 11: ......

Страница 12: ...tered trademark of Franklin Electric Co Inc For technical assistance please contact 1 888 956 0000 Pour l aide technique entrez s il vous pla t en contact 1 888 956 0000 Para la ayuda t cnica por favo...

Отзывы: