LIMITED WARRANTY

SUMP, EFFLUENT & RESIDENTIAL SEWAGE

Little Giant #HT-10E and #HT-6E Series Submersible Effluent 
Pumps are recommended for use in sumps, basins or lift stations 
and suitable for pumping basement drainage water, effluent, 
wastewater and other non-explosive, non-corrosive, non-abrasive 
liquids not above 200°F with up to 3/4” spherical solids (1/2” on 6E 
models) handling ability. (NOT TO BE USED FOR SEWAGE WATER 
EXCEPT TO PUMP SEPTIC TANK EFFLUENT.)
The above noted Little Giant product is guaranteed to be in perfect 
condition when it leaves our factory. During the time periods and 
subject to the conditions hereinafter set forth, LITTLE GIANT PUMP 
COMPANY, subsidiary of Franklin Electric Company, Inc., will repair 
or replace to the original user or consumer any portion of your new 
LlTTLE GIANT product which proves defective due to materials or 
workmanship of LlTTLE GIANT. Contact your nearest authorized Little 
Giant Dealer for warranty service. At all times LlTTLE GIANT shall have 
and possess the sole right and option to determine whether to repair 
or replace defective equipment, parts, or components. Damage due 
to lightning or conditions beyond the control of LITTLE GIANT is NOT 
COVERED BY THIS WARRANTY.

WARRANTY PERIOD

PUMPS: 24 months from date of purchase or 30 months from date 
of manufacture, whichever occurs first.
LABOR, ETC. COSTS: LITTLE GIANT shall IN NO EVENT be 
responsible or liable for the cost of field labor or other charges 
incurred by any customer in removing and/or affixing any LITTLE 
GIANT product, part or component thereof.
THIS WARRANTY WILL NOT APPLY:
 1. to defects or malfunctions resulting from failure to properly 

install, operate, or maintain the unit in accordance with printed 
instructions provided

  2. to failures resulting from abuse, accident or negligence
  3.  to normal maintenance services and the parts used in connection 

with such service

 4. to units which are not installed in accordance with applicable 

local codes, ordinances and good trade practices

 5. unit is used for purposes other than for what it was designed 

and manufactured

 6. if pump exposed to but not limited to the following: sand, 

gravel, cement, grease, plaster, mud, tar, hydrocarbons, or 
hydrocarbon derivatives (oil, gasoline, solvents, etc.) or other 
abrasive or corrosive substances.

 7. if pump has been used for continuous pumping of suitable 

liquids above 200F°

  8. if power cord has been cut to less than 3’ length.
 9. if pump has been dismantled by customer. (Dealer only can 

dismantle pump for field service.)

RETURN OR REPLACED COMPONENTS: Any item to be replaced 
under the Warranty must be returned to LITTLE GIANT at Oklahoma 
City, OK or such other place as LITTLE GIANT may designate, 
freight prepaid.
PRODUCT IMPROVEMENTS: LlTTLE GIANT reserves the right to 
change or improve its products or any portions thereof without 
being obligated to provide such a change or improvement for units 
sold and/or shipped to such change or improvement.
DISCLAIMER: Any oral statements about the product made by the 
seller, the manufacturer, the representatives or any other parties, do 
not constitute warranties, shall not be relied upon by the user, and 
are not part of the contract for sale. Seller’s and manufacturer’s only 
obligation, and buyer’s only remedy, shall be the replacement and/
or repair by the manufacturer of the product as described above. 
Neither seller nor the manufacturer shall be liable for any injury, 
loss or damage, direct, incidental or consequential (including, but 
not limited to, incidental or consequential damages for lost profits, 
lost sales, injury to person or property, or any other incidental or 
consequential loss), arising out of the use or the inability to use the 
product, and the user agrees that no other remedy shall be available 
to it. Before using, the user shall determine the suitability of the 
product for his intended use, and user assumes all risk and liability 
whatsoever in connection therewith. The warranty and remedy 
described in this limited warranty is an EXCLUSIVE warranty and 
remedy and is IN LIEU OF any other warranty or remedy, expressed 
or implied, which other warranties and remedies are hereby expressly 
EXCLUDED, including but not limited to any implied warranty of 
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. 
Some states do not allow the exclusion or limitation of incidental or 
consequential damages, so the above limitation or exclusion may 
not apply to you. This warranty gives you specific legal rights, and 
you may also have other rights which vary from state to state.
In the absence of other suitable proof of the purchase date, the 
effective date of this warranty will be based upon the date of 
manufacture plus two years. Direct all notices, etc., to: Service 
Department, LITTLE GIANT PUMP COMPANY, 301 N. MacARTHUR 
BLVD., OKLAHOMA CITY, OK 73127.
DETERMINATION OF UNIT DATE OF MANUFACTURE: (9-87) 
month and year stamped on pump and/or serial number on pump 
nameplate coded to indicate year of manufacture.

Содержание HT-6E-CIA-FS

Страница 1: ... any other reason a backup system s and or alarm should be used 7 Support pump and piping when assembling and when installed failure to do so may cause piping to break pump to fail motor bearing failures etc 8 This pump s motor housing is filled with a dielectric oil for motor heat transfer and life time lubrication of the bearings This oil is non toxic to aquatic life however suffocation can occu...

Страница 2: ...ion or at an angle of no more than 45 degrees Do not install check valve in a vertical position as solids may settle in valve and prevent opening on start up 6 Do not attempt to restrict the intake side of these pumps Restricting the intake may cause damage to the seal and may starve the pump If you require reduced flow rates then place a valve on the discharge side of the pump or if flexible viny...

Страница 3: ...mp Check rated pump performance Low voltage speed too slow Check for proper supply voltage to make certain it corresponds to nameplate voltage Impeller or discharge pipe is clogged Pull pump and clean Check pipe for scale or corrosion Impeller wear due to abrasives Replace worn impeller Pump cycles continually No check valve in long discharge pipe allowing liquid to drain back into basin Install a...

Страница 4: ...if pump exposed to but not limited to the following sand gravel cement grease plaster mud tar hydrocarbons or hydrocarbon derivatives oil gasoline solvents etc or other abrasive or corrosive substances 7 if pump has been used for continuous pumping of suitable liquids above 200F 8 if power cord has been cut to less than 3 length 9 if pump has been dismantled by customer Dealer only can dismantle p...