The UPSP-5 portable utility transfer pump is intended for intermittent duty, moving water from one location to 
another. The pump can be used to move water from flooded basements, watering lawns and gardens, and drain

-

ing water heaters. It can also be used to boost water pressure for washing vehicles, sidewalks, and decks.
Do not use this pump for:

Submersible applications—submersion will immediately damage the pump

Transferring potable water

Effluent or sewage applications

As a pond pump, or for pumping seawater

Water hotter than 77°F (25°C)

Locations classified as hazardous according to the National Electrical 
Code (ANSI/NFPA)

The pump motor is equipped with an automatic resetting thermal protector, and may 
restart unexpectedly. Thermal Protector tripping is an indication of motor overloading or 
overheating. This can be caused by application issues such as an obstructed pump impeller, 
pump running dry, excessively high or low voltage supply, or possibly a pump, motor, 
bearing, or seal that has reached the end of its useful life.
Please examine your pump carefully to ensure that no damage occurred during shipment. If damage has 
occurred, please contact the place of purchase. They will assist you in replacement or repair, if required. 
This product is covered by a Limited Warranty for a period of 12 months from the date of original purchase by the 
consumer. For complete warranty information, refer to 

www.littlegiant.com

; or, call Technical Support for a 

printed copy.

Specifications

Model

Phase

Volts

Hz

Amps

Breaker Size

Watts

HP

Shut Off

UPSP-5

1

115

60

10

15 A

1020

1/2

145 ft (44 m)

BEFORE GETTING STARTED

This equipment should be installed and serviced by technically 
qualified personnel who are familiar with the correct selection 
and use of appropriate tools, equipment, and procedures. Failure 
to comply with national and local electrical and plumbing codes 
and within Little Giant recommendations may result in electrical 
shock or fire hazard, unsatisfactory performance, or equipment 
failure.
Know the product’s application, limitations, and potential haz

-

ards. Read and follow instructions carefully to avoid injury and 
property damage. Do not disassemble or repair unit unless 
described in this manual.
Refer to product data plate(s) for additional precautions, operat

-

ing instructions and specifications.
Failure to follow installation or operation procedures and all 
applicable codes may result in the following hazards:

Risk of death, personal injury, or 

property damage due to explosion, fire, 

or electric shock.

Do not use to pump flammable or explosive fluids such as 
gasoline, fuel oil, kerosene, etc.

Do not use in explosive atmospheres or hazardous locations 
as classified by the NEC, ANSI/NFPA70.

Do not handle a pump or pump motor with wet hands or 
when standing on a wet or damp surface, or in water until the 
unit is unplugged or electrically disconnected.

If the power disconnect is out of sight, lock it in the open 
position and tag it to prevent unexpected application of 
power.

Do not submerge motor or mount pump in a location where 
motor will come in contact with water.  This pump is not 
designed for use in showers, hot tubs, spas or other poten

-

tially wet locations.

Содержание 555104

Страница 1: ...ed copy Specifications Model Phase Volts Hz Amps Breaker Size Watts HP Shut Off UPSP 5 1 115 60 10 15 A 1020 1 2 145 ft 44 m BEFORE GETTING STARTED This equipment should be installed and serviced by t...

Страница 2: ...human consumption Make sure that the discharge line of the pump is secure before operating pump If the discharge line is not secured it could move Do not oil the motor The pump s motor housing is seal...

Страница 3: ...tion If brushes are less than long they should be replaced If re installing old motor brushes be sure to mark the location from which each came Replace used brushes in original orientation as well One...

Страница 4: ...on power cord plug Tripped overload Allow pump to cool investigate cause i e jammed impeller Worn motor brushes Replace motor brushes Defective motor Replace pump Pump will not prime or loses prime A...

Страница 5: ...tions Mod le Phase Volts Hz Amp res Calibre du disjoncteur Watts HP Arr t UPSP 5 1 115 60 10 15 A 1020 1 2 44 m 145 pi AVANT DE COMMENCER Cet quipement doit tre install et entretenu par des technicien...

Страница 6: ...a ligne de d charge n est pas fix e elle pourrait se d placer Ne pas graisser le moteur Le carter moteur de la pompe est scell et renferme une huile di lectrique de qualit sup rieure pour la transmiss...

Страница 7: ...s Si d anciens balais de moteur sont install s veiller inscrire l emplacement de provenance de chacun Replacer galement les balais us s dans l orientation d origine Un ensemble suppl mentaire de bala...

Страница 8: ...et chercher la cause p ex blocage de la roue Les balais du moteur sont us s Remplacer les balais du moteur Le moteur est d fectueux Remplacer la pompe La pompe ne s amorce pas ou perd son amor age Il...

Страница 9: ...o bien llame al departamento de Soporte t cnico para obtener una copia impresa Especificaciones Modelo Fase Voltios Hz A Tama o del disyuntor Vatios HP Apagado UPSP 5 1 115 60 10 15 A 1020 1 2 145 pie...

Страница 10: ...e la bomba est segura antes de utilizar la bomba Si la l nea de descarga no est ase gurada podr a moverse No aplique aceite al motor La carcasa del motor de la bomba est sellada y contiene un aceite d...

Страница 11: ...a las escobillas de motor viejas aseg rese de marcar la ubicaci n de donde proviene cada una Reemplace las escobillas usadas en la orienta ci n original tambi n Se incluye un juego adicional de escobi...

Страница 12: ...rqu se atasc el impulsor Escobillas de motor desgastadas Reemplace las escobillas del motor Motor defectuoso Reemplace la bomba La bomba no ceba o pierde cebado Fuga de aire en la l nea de succi n Ubi...

Отзывы: