background image

5-MSP SERIES

MODÈLES DE LA 

SÉRIE 5-MSP

MODELOS DE LA 

SERIE 5-MSP

INTRODUCTION

EN

This instruction sheet provides you with the information required to safely own 

and operate your product. Retain these instructions for future reference.
The product you have purchased is of the highest quality workmanship and 

material, and has been engineered to give you long and reliable service. This 

product has been carefully tested, inspected, and packaged to ensure safe 

delivery and operation. Please examine your item(s) carefully to ensure that no 

damage occurred during shipment. If damage has occurred, please contact the 

place of purchase. They will assist you in replacement or repair, if required.
READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO 

INSTALL, OPERATE, OR SERVICE YOUR PRODUCT. KNOW THE PRODUCT’S 

APPLICATION, LIMITATIONS, AND POTENTIAL HAZARDS. PROTECT YOURSELF 

AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO 

COMPLY WITH THESE INSTRUCTIONS COULD RESULT IN PERSONAL INJURY 

AND/OR PROPERTY DAMAGE!

SAFETY GUIDELINES

 1.  Ensure that unit is disconnected from power source before attempting to 

service or remove any component.

 2.  Do not use to pump flammable or explosive fluids such as gasoline, fuel oil, 

kerosene, etc. Do not use in explosive atmospheres. Pump should only be 

used with liquids compatible with pump component materials.

 3.  Do not handle pump with wet hands or when standing on a wet or damp 

surface or in water.

 4.  This pump is supplied with a grounding conductor and/or grounding-type 

attachment plug. To reduce the risk of electric shock, be certain that it is 

connected to a properly grounded grounding-type receptacle.

  5.  In any installation where property damage and/or personal injury might result from 

an inoperative or leaking pump due to power outages, discharge line blockage, 

or any other reason, a backup system(s) and/or alarm should be used.

  6.  Support pump and piping when assembling and when installed. Failure to do 

so may cause piping to break, pump to fall, motor bearing failures, etc.

 7.  If pump is an oil-filled pump, the motor housing is filled with a dielectric 

lubricant at the factory for optimum motor heat transfer and lifetime 

lubrication of the bearings. Use of any other lubricant could cause damage 

and void the warranty. This lubricant is non-toxic; however, if it escapes the 

motor housing, it should be removed from the surface quickly by placing 

newspapers or other absorbent material on the water surface to soak it up, 

so aquatic life is undisturbed.

ELECTRICAL CONNECTIONS

  1.  Check the pump label for proper voltage required. Do not connect to voltage 

other than that shown.

  2.  If pump is supplied with a 3-prong electrical plug, the third prong is to ground 

the pump to prevent possible electrical shock hazard. DO NOT REMOVE the 

third prong from the plug. A separate branch circuit is recommended. Do not 

use an extension cord. Do not cut plug from the cord. If the plug is cut or the 

cord is shortened, then this action will void the warranty.

  3.  If the cord is equipped with stripped lead wires, such as on 230V models, be sure 

that the lead wires are connected to a power source correctly. The green/yellow 

wire is the ground. The blue (or white) and the brown (or black) are live.

CONSULT INSTRUCTION SHEET ILLUSTRATIONS FOR PROPER ASSEMBLY 

AND DISASSEMBLY OF YOUR PUMP.

OPERATION

  1.  Place pump on solid surface in water at least 3/4” deep to begin pumping. 

Pump should be totally submerged for proper cooling of the motor when 

pump is operated for extended periods.

 2.  Connect garden hose to hose adaptor or 1” diameter pipe directly into 

pump outlet.

 3.  Pump with screen will remove water to within 3/8”. Pump without screen (it 

will snap off by wedging a coin between the slots; see Figure 2) will remove 

water to within 1/8”.

 4.  If the surface is dirt or sand, place pump on flat surface such as a piece of 

wood or metal to prevent it from being clogged.

 5.  Do not let the unit run dry. It is designed to be cooled by pumping fluid. You 

may damage the seal and the motor may fail if the pump is allowed to run dry.

 6. If the unit is going to be idle for a period of time, follow the cleaning 

instructions outlined in the next section. Do not let the unit freeze in the 

wintertime. This may cause cracking or distortion that may destroy the unit.

 7. When using 3/4” garden hose adaptor performance will be reduced 

approximately 15%. This pump does not deliver enough pressure to operate 

lawn sprinklers properly.

 8.  If fused-type plug is used on 230V units, a 5.0 amp fuse is recommended.
 9. If using an aluminum body pump in an area with water having a high 

mineral content (hard water) or if other metals (copper tubing, metal fountain 

heads, etc.) are present in the pond or fountain, a condition called “galvanic 

corrosion” may occur. The recommended solution to this situation is the use 

of a sacrificial anode attached to the pump. This anode works on the same 

principle as the anode found in hot water heaters and boat motors. Contact 

your local distributor and ask for the model SA-1 by Little Giant.

MAINTENANCE

MAKE CERTAIN THE UNIT IS DISCONNECTED FROM THE POWER SOURCE 

BEFORE ATTEMPTING TO SERVICE OR REMOVE ANY COMPONENT!
  1.  The motor housing of the pump is completely sealed and requires no service. 

Disassembly of the motor housing or alteration of the power cord voids all 

warranty. The power cord on these units cannot be replaced. In case of 

damage the whole unit must be replaced.

 2.  The motor is a continuous duty type sealed in oil with an automatic thermal 

overload protector device.

 3.  The pump can run against a restricted discharge such as a fountain without 

damage to the pump.

 4.  If the pump becomes clogged snap the screen off and clean out the area.
 5. If necessary remove the 6 screws holding the volute base to the motor 

housing and clean the volute.

 6.  If the impeller is removed, make sure that a spacing of .050” (1.27 mm) with 

shaft pushed toward housing is maintained when reassembling (Figure 1).

 7.  When reassembling, remember to install the seal ring between the volute 

base and the motor housing.

INTRODUCTION

FR

Cette feuille d’instructions vous fournit les informations nécessaires pour 

entretenir et faire fonctionner votre produit. Conserver ces directives afin de 

pouvoir les consulter plus tard.
Le produit que vous avez acheté a été soigneusement fabriqué avec des matériaux 

de la plus haute qualité et a été conçu pour durer longtemps et offrir un service 

fiable. Les produits sont soigneusement testés, inspectés et emballés afin d’en 

assurer la sécurité de fonctionnement et une livraison en bonne condition. Vérifier 

attentivement le produit afin de vous assurer qu’il n’a pas été endommagé pendant 

le transport. S’il est endommagé, veuillez contacter l’entreprise qui vous l’a vendu. 

Si une réparation ou un remplacement est requis, elle vous prêtera assistance.
LIRE ATTENTIVEMENT CES DIRECTIVES AVANT DE PROCÉDER À 

L’INSTALLATION, À L’UTILISATION OU À L’ENTRETIEN DU PRODUIT. SE 

FAMILIARISER AVEC LES APPLICATIONS, LES LIMITES ET LES RISQUES 

POTENTIELS DU PRODUIT. ASSURER SA PROPRE PROTECTION ET CELLE 

DES AUTRES EN SUIVANT TOUTES LES RÈGLES DE SÉCURITÉ. LE NON-

RESPECT DE CES DIRECTIVES PEUT ENTRAÎNER DES BLESSURES ET/OU 

DES DOMMAGES MATÉRIELS!

DIRECTIVES DE SÉCURITÉ

  1.  Veiller à débrancher l’appareil de sa source d’alimentation électrique avant 

l’entretien ou la dépose d’une ou de plusieurs piéces.

 2. Ne pas pomper des fluides explosifs ou inflammables tels qu’essence, 

mazout, kérosène, etc. Ne pas employer dans une atmosphère comportant 

des risques de déflagration. La pompe ne doit servir qu’à pomper des 

liquides compatibles avec les matériaux utilisés pour la fabrication des 

éléments qui la composent.

  3.  Ne pas manipuler la pompe les mains 

humides, les pieds posés sur une 

surface mouillée ou humide, ou les 

pieds dans l’eau.

 4. Cette pompe est équipée d’un 

conducteur de mise à la terre et ou 

d’une fiche de branchement à prise 

de terre. Pour réduire les risques 

d’électrocution, s’assurer qu’elle 

est bien raccordée à une prise de 

courant appropriée comportant une 

borne de mise à la terre.

Franklin Electric Co., Inc.

P. O. Box 12010

Oklahoma City, OK 73157-2010

405.947.2511 • Fax: 405.947.8720

www.LittleGiantPump.com

[email protected]

Figure 1

1

Отзывы: