ENGLISH
EN
This instruction sheet provides you with the information required
to safely own and operate your product. Retain these instructions
for future reference.
The product you have purchased is of the highest quality
workmanship and material, and has been engineered to give you
long and reliable service. This product has been carefully tested,
inspected, and packaged to ensure safe delivery and operation.
Please examine your item(s) carefully to ensure that no damage
occurred during shipment. If damage has occurred, please
contact the place of purchase. They will assist you in replacement
or repair, if required.
READ THESE INSTRUCTIONS CAREFULLY BEFORE
ATTEMPTING TO INSTALL, OPERATE, OR SERVICE
YOUR PRODUCT. KNOW THE PRODUCT’S APPLICATION,
LIMITATIONS, AND POTENTIAL HAZARDS. PROTECT
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION. FAILURE TO COMPLY WITH THESE
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY
AND/OR PROPERTY DAMAGE!
DESCRIPTION
Little Giant submersible 14S and 16S series sewage ejector
pumps and 14EH/16EH series effluent pumps are recommended
for use in basins or lift stations and are suitable for pumping
sewage, effluent, wastewater, and other non-explosive, non-
corrosive liquids.
Little Giant offers a complete line of float switches and liquid level
control systems for automatic operation, along with a complete
line of alarms, basins, covers, and check valves.
SAFETY GUIDELINES
WARNING
READ ALL INSTRUCTIONS AND SAFETY GUIDELINES
THOROUGHLY. FAILURE TO FOLLOW THE GUIDELINES AND
THE INSTRUCTIONS COULD RESULT IN SERIOUS BODILY
INJURY AND/OR PROPERTY DAMAGE.
WARNING: RISK OF ELECTRIC SHOCK.
This pump is supplied
with a grounding conductor and/or grounding type attachment
plug. To reduce the risk of electric shock, connect it only to a
properly grounded, grounding-type receptacle.
If this pump is equipped with a 3-prong electrical plug, the third
prong grounds the pump to prevent possible electrical shock
hazard. Do not remove the third prong from the plug. A separate
branch circuit is recommended. Do not use an extension cord.
When the pump is in a basin, sump, lift station, etc., do not touch
the motor, pipes, or water until the pump is unplugged or shut off.
If your installation has water or moisture present, do not touch the
wet area until all power has been turned off. If the shut-off box is
not accessible, call the electric company to shut off service to the
1
14S-CIM
16S-CIM
14EH-CIM
16EH-CIM
MODEL
LISTING
HP
VOLTS
AMPS/
WATTS
GALLONS PER MINUTE @ FEET OF HEAD
POWER
CORD
(ft.)
WEIGHT
(lbs.)
5'
10'
20'
30'
40'
50'
60'
SHUT-OFF P.S.I.
14EH-CIM
UL
1/2
115
12.5/1450
NR
NR
60
40
20
--
--
50'
21.6
20
74
14EH-CIM
UL
1/2
208-240
5.7/1275
NR
NR
60
40
20
--
--
50'
21.6
20
74
14S-CIM
UL
1/2
115
11.6/1100
130
100
35
--
--
--
--
25'
10.8
20
80
14S-CIM
UL
1/2
208-240
4.6/1100
130
100
35
--
--
--
--
25'
10.8
20
80
16EH-CIM
UL
1
230
9.0/2200
NR
NR
NR
90
70
50
30
81'
35.1
20
82
16S-CIM
UL
1
230
11.0/1900
180
160
100
40
--
--
--
35'
15.1
20
88
16S-CIM
UL
1
200-208
11.0/2000
180
160
100
40
--
--
--
35'
15.1
20
88
NR:
Not recommended. Operation at these heads or below will result in motor overload, reduced pump life, and/or motor failure/damage.
Figure 1 - Dimensions
Franklin Electric Co., Inc.
P. O. Box 12010
Oklahoma City, OK 73157-2010
Phone: 405-947-2511 • Fax: 405-947-8720
www.LittleGiantPump.com
PumpAgents.com - Click here for Pricing/Ordering
PumpAgents.com - Click here for Pricing/Ordering