Pump can be installed with ABS, PVC, polyethylene or galvanized 
steel pipe. Proper adapters are required to connect plastic pipe 
to pump.
A union should be installed just above the cover to facilitate pump 
removal if necessary.
A check valve must be used in the discharge line to prevent back 
flow of liquid into the basin. The check valve should be a free flow 
valve that will easily pass solids.

CAUTION:

 For best performance of check valves, when handling 

solids install in a horizontal position or at an angle of no more than 
45°. Do not install check valve in a vertical position, as solids may 
settle in valve and prevent opening on start-up.
A gate valve should follow the check valve to allow periodic 
cleaning of the check valve or removal of the pump.
The remainder of the discharge line should be as short as 
possible with a minimum of turns to minimize friction head loss. 
Do not restrict the discharge to sizes below 2”.
Sewage and effluent applications will require a separate sump 
vent. A connection is provided on top of the sump or cover which 
must be piped to the existing building vent or extended outside 
with its own standpipe.

WIRING

Check local electrical and building codes before installation. The 
installation must be in accordance with their regulations as well as 
the most recent National Electrical Code (NEC).
To conform to the National Electrical Code, all pumps must be 
wired with 14 AWG or larger wire. For runs to 250 feet, 14 AWG 
wire is sufficient. For longer runs, consult a qualified electrician or 
the factory.

Pump should be connected or wired to its own circuit with no 
other outlets or equipment in the circuit line. Fuses and circuit 
breaker should be of ample capacity in the electrical circuit. See 
chart below.

 

 

 

FUSE OR CIRCUIT

 H.P. 

VOLTAGE BREAKER 

AMPS

 ½, 

115 

20

 ½, 

230 

15

MAINTENANCE AND SERVICE

If pump does not operate properly, consult the Trouble Shooting 
Chart. If trouble cannot be located with these steps shown, 
consult your pump dealer or take pump to a Little Giant authorized 
service center.

CAUTION:

 When working on pump or switch, always unplug 

pump power cord in addition to removing fuse or shutting of 
circuit breaker before working on pump.

CLEANING IMPELLER AND VOLUTE

WARNING: DO NOT REMOVE THE SOCKET HEAD CAP SCREWS 
(ITEM #16 ON PARTS LIST). THE MOTOR SECTION OF YOUR 
PUMP IS PERMANENTLY LUBRICATED WITH DIELECTRIC 
OIL AND SEALED AT THE FACTORY. REMOVAL OF THESE 
SOCKET HEAD CAP SCREWS BY ANYONE OTHER THAN AN 
AUTHORIZED LITTLE GIANT SERVICE CENTER WILL BREAK 
THIS SEAL AND VOID THE WARRANTY.
 1. Remove the 4 screws (item #27 on parts list) that hold the 

volute to the motor housing.

  2. Clean impeller and volute passage.
  3. Be sure impeller turns freely after cleaning.

3

Figure 3 - Typical Installation

Содержание 14EH Series

Страница 1: ...series stainless steel BEARING Ball SHAFT SEAL Mechanical spring loaded rotating carbon with Nitrile boot and stationary ceramic seat with secondary Nitrile exclusion seal POWER CORD 16 AWG 3 conduct...

Страница 2: ...AS GASOLINE FUEL OIL KEROSENE ETC FAILURE TO FOLLOW THIS WARNING CAN RESULT IN PERSONAL INJURY AND OR PROPERTY DAMAGE 2 During normal operation the pump is immersed in water Also during rain storms w...

Страница 3: ...ions as well as the most recent National Electrical Code NEC To conform to the National Electrical Code all pumps must be wired with 14 AWG or larger wire For runs to 250 feet 14 AWG wire is sufficien...

Страница 4: ...4 Figure 4...

Страница 5: ...T 1 1 1 1 1 9 114009 DISCH FLANGE 3 FNPT 1 1 1 1 10 903722 SCREW 7 16 14 x 1 1 4 2 2 2 2 2 2 2 2 2 11 921104 LOCK WASHER 7 16 2 2 2 2 2 2 2 2 2 12 114101 FLANGE GASKET 1 1 1 1 1 1 1 1 1 13 114038 VOLU...

Страница 6: ...ately 2 above discharge connections Liquid inflow matches pump capacity Larger pump required Defective switch Disconnect switch check w ohmmeter Open infinitive resistance closed zero Loose connection...

Страница 7: ...oil gasoline solvents etc or other abrasive or corrosive substances 7 if pump has been used for continuous pumping of suitable liquids above 140 F 8 if power cord has been cut or spliced 9 if pump ha...

Страница 8: ...ctric Co Inc Little Giant is a registered trademark of Franklin Electric Co Inc For parts or repair please contact 1 888 572 9933 For technical assistance please contact 1 888 956 0000 www LittleGiant...

Отзывы: