Little Giant 14EH Series Скачать руководство пользователя страница 1

INTRODUCTION

Little Giant Submersible 14S and 16S Series Sewage Ejector 
Pumps and 14EH and 16EH Series Effluent Pumps are 
recommended for use in basins or lift stations and suitable for 
pumping sewage, effluent, wastewater and other non-explosive, 
non-corrosive liquids. The S Series Sewage Ejector Pumps have 
2” spherical solids handling capability. The EH Series Effluent 
Pumps have 3/4” spherical solids handling capability.
Little Giant offers a complete line of float switches and liquid level 
control systems for automatic operation along with a complete 
line of alarms, basins, covers, and check valves.

UNPACKING

Little Giant pumps are carefully packaged, inspected and tested 
to insure safe operation and delivery. When you receive your 
pump, examine it carefully to determine that there are no broken 
or damaged parts that may have occurred during shipment. If 
damage has occurred, make notation and notify the firm from 
which you purchased the pump and they will assist you in 
replacement or repair, if required.

SPECIFICATIONS

DISCHARGE:

 14EH & 16EH – 2”, 14S – 2” or 3”, 16S – 3”.

HANDLING CAPABILITIES:

 EH Series – 3/4” spherical solids, 

S Series – 2” spherical solids

HOUSING:

 Cast Iron

VOLUTE:

 Cast Iron

IMPELLER:

 Non-clog Cast Iron, with pressure relief vanes.

MOTOR:

 PSC, 3450 RPM (EH Series), 1625 RPM (S Series), with 

automatic overload protection

HARDWARE:

 300 series stainless steel

BEARING:

 Ball

SHAFT SEAL:

 Mechanical, spring loaded, rotating carbon with 

Nitrile boot and stationary ceramic seat, with secondary Nitrile 
exclusion seal

POWER CORD:

 16 AWG 3-conductor copper stranded; 18 AWG 

(208-240V models)

COOLING:

 The motor housing contains a cooling oil to provide 

cooling for the motor and to lubricate bearings and seals. These 
pumps are capable of operating with the motor housing partially 
exposed for extended periods of time, providing sufficient motor 
cooling and bearing lubrication, however, for the best cooling and 
longest motor life, the liquid level being pumped should normally 
be above the top of the cast iron motor housing.

1

14S-CIM

16S-CIM

14EH-CIM

16EH-CIM

MODEL 

NO.

LISTING

HP

VOLTS

AMPS/

WATTS

PERFORMANCE GPM @ HEAD SHUTOFF

PWR 

CORD 

(ft.)

WEIGHT 

(lbs.)

5’

10’

20’

30’

40’

50’

60’

(Ft.) P.S.I.

14EH-CIM

UL

1/2

115

12.5/1450

NR

NR

60

40

20

50

21.6

20

74

14EH-CIM

UL

1/2

208-240

5.7/1275

NR

NR

60

40

20

50

21.6

20

74

14S-CIM

UL

1/2

115

11.6/1100

130

100

35

25

10.8

20

80

14S-CIM

UL

1/2

208-240

4.6/1100

130

100

35

25

10.8

20

80

16EH-CIM

UL

1

230

9.0/2200

NR

NR

NR

90

70

50

30

81

35.1

20

82

16S-CIM

UL

1

230

11.0/1900

180

160

100

40

35

15.1

20

88

16S-CIM

UL

1

200-208

11.0/2000

180

160

100

40

35

15.1

20

88

NR:

 Not Recommended, operation at these heads or below will result in motor overload, reduced pump life and/or motor failure/damage.

Figure 1

Franklin Electric Co., Inc.

P. O. Box 12010

Oklahoma City, OK 73157-2010

405.947.2511 • Fax: 405.947.8720

www.LittleGiantPump.com

[email protected]

Содержание 14EH Series

Страница 1: ...series stainless steel BEARING Ball SHAFT SEAL Mechanical spring loaded rotating carbon with Nitrile boot and stationary ceramic seat with secondary Nitrile exclusion seal POWER CORD 16 AWG 3 conduct...

Страница 2: ...AS GASOLINE FUEL OIL KEROSENE ETC FAILURE TO FOLLOW THIS WARNING CAN RESULT IN PERSONAL INJURY AND OR PROPERTY DAMAGE 2 During normal operation the pump is immersed in water Also during rain storms w...

Страница 3: ...ions as well as the most recent National Electrical Code NEC To conform to the National Electrical Code all pumps must be wired with 14 AWG or larger wire For runs to 250 feet 14 AWG wire is sufficien...

Страница 4: ...4 Figure 4...

Страница 5: ...T 1 1 1 1 1 9 114009 DISCH FLANGE 3 FNPT 1 1 1 1 10 903722 SCREW 7 16 14 x 1 1 4 2 2 2 2 2 2 2 2 2 11 921104 LOCK WASHER 7 16 2 2 2 2 2 2 2 2 2 12 114101 FLANGE GASKET 1 1 1 1 1 1 1 1 1 13 114038 VOLU...

Страница 6: ...ately 2 above discharge connections Liquid inflow matches pump capacity Larger pump required Defective switch Disconnect switch check w ohmmeter Open infinitive resistance closed zero Loose connection...

Страница 7: ...oil gasoline solvents etc or other abrasive or corrosive substances 7 if pump has been used for continuous pumping of suitable liquids above 140 F 8 if power cord has been cut or spliced 9 if pump ha...

Страница 8: ...ctric Co Inc Little Giant is a registered trademark of Franklin Electric Co Inc For parts or repair please contact 1 888 572 9933 For technical assistance please contact 1 888 956 0000 www LittleGiant...

Отзывы: