background image

INTRODUCTION

Little Giant Submersible 10SH Series Sewage Ejector Pumps are recommended for use in basins or lift 

stations and suitable for pumping sewage, effluent, wastewater and other non-explosive, non-corrosive 

liquids. The 10SH Series Sewage Ejector Pumps have 1-1/4" spherical solids handling capability.
Automatic operation can be achieved with the use of the RFS Remote Float Switch. Other accessories 

such as basins, check valves and covers are also available.

UNPACKING

Little  Giant  pumps  are  carefully  packaged,  inspected  and  tested  to  insure  safe  operation  and  delivery. 

When you receive your pump, examine it carefully to determine that there are no broken or damaged parts 

that may have occurred during shipment. If damage has occurred, make notation and notify the firm from 

which you purchased the pump and they will assist you in replacement or repair, if required.

SPeCIfICAtIoNS

Discharge: 

10SH Series    2" NPT vertical

Intake: 

10SH Series    1.75" diameter opening

Housing: 

Cast iron

Volute: 

Cast iron

Impeller: 

Vortex design nylon, with pressure relief vanes

Motor: 

Split phase induction, 1750 RPM, with automatic reset thermal overload protection

Hardware: 

300 Series stainless steel

Bearing: 

Double shielded ball

Shaft Seal: 

Mechanical, spring loaded, stationary carbon with Nitrile boot and rotating ceramic seat

Power Cord:  16 AWG 3-conductor copper stranded
Cooling: 

The motor housing contains a cooling oil to provide cooling for the motor and to lubricate 

bearings and seals. These pumps are capable of operating with the motor housing partially 

exposed  for  extended  periods  of  time,  providing  sufficient  motor  cooling  and  bearing 

lubrication.  However,  for  the  best  cooling  and  longest  motor  life,  the  liquid  level  being 

pumped should normally be above the top of the cast iron motor housing.

SAfetY GUIDeLINeS

WARNING: RISK of eLeCtRIC SHoCK. this pump is supplied with a grounding conductor and/or 

grounding type attachment plug. to reduce the risk of electric shock, be certain that it is connected 

to a properly grounded grounding type receptacle.
Your pump is equipped with a 3-prong electrical plug. The third prong is to ground the pump to prevent 

possible electrical shock hazard. Do not remove the third prong from the plug. A separate branch circuit 

is recommended. Do not use an extension cord.
When a pump is in a basin, etc., do not touch motor, pipes or water until unit is unplugged or shut off. If 

shut-off box is not accessible, call the electric company to shut off service to the house, or call your local 

fire department for instructions. Failure to follow this warning can result in fatal electrical shock.
The flexible PVC jacketed cord assembly mounted to the pump must not be modified in any way, with the 

exception of shortening the cord to fit into a control panel. Any splice between the pump and the control 

panel must be made within a junction box and mounted outside of the basin, and comply with the National 

Electrical Code. Do not use the power cord for lifting the pump.
The pump motor is equipped with an automatic resetting thermal protector and may restart unexpectedly. 

Protector tripping is an indication of motor overloading as a result of operating the pump at low heads (low 

discharge restriction), excessively high or low voltage, inadequate wiring, incorrect motor connections, or 

a defective motor or pump.
  1. Read all instructions and Safety Guidelines thoroughly. Failure to follow the guidelines and instructions 

could result in serious bodily injury and/or property damage.

  2. DO  NOT  USE  TO  PUMP  FLAMMABLE  OR  EXPLOSIVE  FLUIDS  SUCH  AS  GASOLINE,  FUEL  OIL, 

KEROSENE,  ETC.  DO  NOT  USE  IN  EXPLOSIVE  ATMOSPHERES  OR  HAZARDOUS  LOCATIONS 

AS  CLASSIFIED  BY  NEC,  ANSI/NFPA70.  FAILURE  TO  FOLLOW  THIS  WARNING  CAN  RESULT  IN 

PERSONAL INJURY AND/OR PROPERTY DAMAGE.

  3. During normal operation the pump is immersed in water. Also, during rain storms, water may be present 

in the surrounding area of the pump. Caution must be used to prevent bodily injury when working near 

the pump:

  a. The plug must be removed from the receptacle prior to touching, servicing or repairing the pump.
  b. To minimize possible fatal electrical shock hazard, extreme care should be used when changing 

fuses. Do not stand in water while changing fuses or insert your finger into the fuse socket.

  4. Do not run the pump in a dry basin. If the pump is run in a dry basin, the surface temperature of the 

pump will rise to a high level. This high level could cause skin burns if the pump is touched and will 

cause serious damage to your pump.

  5. Do not oil the motor. The pump housing is sealed. A high grade dielectric oil devoid of water has been 

put into the motor housing at the factory. Use of other oil could cause serious electric shock and/or 

permanent damage to the pump.

  6. This pump’s motor housing is filled with a dielectric lubricant at the factory for optimum motor heat 

transfer and lifetime lubrication of the bearings. Use of any other lubricant could cause damage and 

void the warranty. This lubricant is non-toxic; however, if it escapes the motor housing, it should be 

removed from the surface quickly by placing newspapers or other absorbent material on the water 

surface to soak it up, so aquatic life is undisturbed.

INStALLAtIoN

Pump must be installed in a suitable gas tight basin which is at least 18" in diameter and 30" deep, and 

vented in accordance with local plumbing codes.
10SH Series Sewage Pumps feature a 2" female NPT discharge.
Pump can be installed with ABS, PVC, polyethylene or galvanized steel pipe. Proper adapters are required 

to connect plastic pipe to pump.

Pump must be placed on a hard level surface. Never place pump directly on clay, earth or gravel surfaces.
A check valve must be used in the discharge line to prevent backflow of liquid into the basin. The check 

valve should be a free flow valve that will easily pass solids.
CAUtIoN: For best performance of check valves, when handling solids install in a horizontal position or at 

an angle of no more than 45°. Do not install check valve in a vertical position as solids may settle in valve 

and prevent opening on start-up.
When a check valve is used drill a 3/16" hole in the discharge pipe approximately 1" to 2" above the pump 

discharge connection and below check valve to prevent air locking of the pump.

WIRING

Check local electrical and building codes before installation. The installation must be in accordance with 

their regulations as well as the most recent National Electrical Code (NEC).
To conform to the National Electrical Code all pumps must be wired with 14 AWG or larger wire. For runs 

to 250', 14 AWG wire is sufficient. For longer runs, consult a qualified electrician or the factory.
Pump should be connected or wired to its own circuit with no other outlets or equipment in the circuit line. 

Fuses and circuit breaker should be of ample capacity in the electrical circuit. See chart below.

H.P.

VOLTAGE

FUSE OR CIRCUIT 

BREAKER AMPS

1/2

115

20

1/2

230

15

ReMote fLoAt 

SWItCH LeVeL 

CoNtRoL

The RFS series pumps are equipped with a remote float switch level control. This level control is sealed in 

a polypropylene float cylinder. For automatic operation, the pump must be plugged or wired into a remote 

float switch. Pump will run continuously if plugged directly into an electrical outlet.
When the level rises in the basin, the cylinder floats up with the level. When the cylinder position is at an 

angle of about 45° the switch activates and starts the pump motor.
As the level draws down, the cylinder floats down and when it is again at an angle of about 45°, the switch 

deactivates, and the pump motor stops.
NOTE: BE CERTAIN PUMP IS SECURE IN BASIN AND CYLINDER FLOATS UNOBSTRUCTED WITHOUT 

TOUCHING THE BASIN WALLS OR PLUMBING.

ReMote fLoAt SWItCH INStALLAtIoN

  1. The float switch consists of three parts:

  a. switch
  b. cord clamp
  c. clamp screw

    Note: If screw is lost, use a #10-16 x 1/2" long tapping screw.
  2. Attach cord clamp to pump cover as shown in Figure 3. The clamp must be positioned as shown to 

allow free operation of float. Be sure to locate pump and switch power cords away from switch float.

  3. A 3-1/2" tether length is recommended. When a tether length of 3-1/2" is used, a minimum basin 

diameter of 18" is recommended. The tether length is measured as shown in Figure 3.

  4. After desired tether length is established hand tighten clamp screw.
  5. TESTING: Without water in basin plug pump power cord into switch in-line-plug. Plug switch into 

outlet. Lift float and watch for pump to operate. Do not run pump for more than 5 seconds.

oPeRAtIoN

teStING PUMP oPeRAtIoN
RfS SeRIeS SeWAGe eJeCtoR PUMPS
  1. These pumps are equipped with a remote float switch.
  2. These pumps are installed in a basin with a sealed cover, so switch operation cannot be observed. 

The sump cover usually will have a spare hole that is plugged with a rubber plug. This plug can be 

removed and switch operation can be observed.

  3. Plug power cord and remote float switch power cord into a grounded receptacle with voltage consistent 

with pump voltage as indicated on pump nameplate.

  4. Run water into basin until pump starts.
  5. Be sure gate valve in discharge line is open.
  6. Allow pump to operate through several on-off cycles.
MANUAL SeWAGe eJeCtoR PUMPS
The pump cord for these pumps can be plugged directly into a properly grounded receptacle with voltage 

consistent with pump nameplate for continuous pump operation.
CAUtIoN: This type of operation should be used only for emergency use or when a large volume of water 

is to be pumped. Pump must not be allowed to run dry. If pump is run dry, it may damage pump and void 

the warranty.

MAINteNANCe AND SeRVICe

If pump does not operate properly, consult the Troubleshooting Chart. If trouble can not be located with 

these steps shown, consult your pump dealer or take pump to a Little Giant authorized service center.
CAUtIoN: When working on pump or switch, always unplug pump power cord in addition to removing 

fuse or shutting off circuit breaker before working on pump.

CLeANING IMPeLLeR AND VoLUte

  1. Remove screws that hold volute to motor housing.
  2. Remove volute and clean impeller and volute passage. Do not use strong solvents on impeller.
  3. Be sure impeller turns freely after cleaning.
  4. WARNING:  DO  NOT  REMOVE  IMPELLER.  REMOVAL  OF  IMPELLER  REQUIRES  SPECIAL  TOOLS 

AND  IS  TO  BE  DONE  ONLY  BY  AN  AUTHORIZED  SERVICE  CENTER.DO  NOT  REMOVE  MOTOR 

HOUSING COVER. WARRANTY IS VOID IF MOTOR HOUSING COVER, IMPELLER OR SEALS HAVE 

BEEN REMOVED.

    ANY REPAIR ON MOTOR MUST BE DONE BY AN AUTHORIZED LITTLE GIANT SERVICE CENTER.

10SH-CIM

10SH-CIA-RfS

figure 1.

Model No.

Catalog No.

Listing(s)

HP

Volts

Solids Size 

(dia. in.)

Amps/

Watts

GPM @ Head

Shut Off

P.S.I.

Power Cord 

(ft.)

Wt. 

(lbs.)

Dimensions

(H x L x W in In.)

10'

15'

20'

25'

10SH-CIM

511420

UL/CSA

1/2

115

1-1/4"

11/900

100

80

55

20

28'

12.1

15

41.5

12.00 x 10.3 x 8.25

10SH-CIM

511480

UL/CSA

1/2

208-240

1-1/4"

5.5/900

100

80

55

20

28'

12.1

15

41.5

12.00 x 10.3 x 8.25

10SH-CIA-RFS

511520

UL/CSA

1/2

115

1-1/4"

11/900

100

80

55

20

28'

12.1

15

41.5

12.00 x 10.3 x 8.25

figure 2.

Little Giant

P. O. Box 12010

Oklahoma City, OK 73157-2010

405.947.2511 • Fax: 405.947.8720

www.LittleGiant.com

[email protected]