CARE, STORAGE, REPAIR AND DISPOSAL

1.  Keep this Device from exposure to higher humidity, direct sunlight, shocks.

2.  Do not keep and use this Device near heating installations and open fi re.

3.  Keep the Device clean and protect it from dust.

4.  Contact of device with aggressive solutions is not allowed.

5.  Protect the arm cuff  and air tubes from contacting on sharp things.

6.  This Device does not contain special controls to adjust the measurement 

accuracy. Independent opening of manometer is prohibited. Repair the 
Device only in authorized organizations.

7.  Service life of device is indicated in section TECHNICAL SPECIFICATIONS. 

Service life is determined from the moment of commodity delivery to the 
customer. On expiration of the warranted service life apply from time to 
time to authorized repair organizations to check the technical condition of 
the Device.

8.  Dispose of the Device and its components according to the application 

local regulations. No special requirements to disposal of this Device are 
defi ned by the manufacturer. 

9.  The arm cuff  may withstand multiple sanitary treatments. The internal tissue 

surface of the arm cuff  (contacting on arm) may be cleaned with cotton ball 
soaked in 3%-solution of hydrogen peroxide. At long use the partial color fad-
ing of the tissue coating of the arm cuff  is possible. Washing and ironing of 
the arm cuff  are not allowed.

WARRANTY

1. The following LD product is covered by warranty for the period specifi ed 

in the warranty card. 

2. The warranty period for the arm cuff  is 12 months from the date of sale.

3. The warranty liabilities are contained in the warranty card given at the sale 

of this Device to a purchaser.

4. The addresses of organizations for warranty maintenance are given in the 

warranty card.

Содержание LD-91

Страница 1: ...Ci nieniomierz mechaniczny LD do pomiaru ci nienia t tniczego krwi Instrukcja obs ugi Blood Pressure Monitor Instruction Manual POL ENG LD 91...

Страница 2: ...ticoagulants antithrombo cytes or steroids Use of device in these cases may cause internal hemorrhage 2 For correct measurement you should know that THE BLOOD PRESSURE IS SUBJECT TO SHARP VARIATIONS E...

Страница 3: ...UR BLOOD PRESSURE WITH THE ELECTRONIC DEVICE Measure your blood pressure in the calm and comfortable conditions at the indoor tem perature No eating an hour before measurement no smoking taking tonic...

Страница 4: ...so that the air tube is directed to your palm g 4 If the measurement on your left arm is di cult you may use your right arm In this case remember that the readings may di er by 5 10 mmHg and even more...

Страница 5: ...CUFF WOULD BE LOCATED AT THE LEVEL OF HEART AND HAND WOULD BE FREELY LOCATED ON THE TABLE AND WOULD NOT MOVE MEASUREMENT PROCEDURE 1 Insert metal tubes of stethoscope into ears Close air valve on air...

Страница 6: ...o time to authorized repair organizations to check the technical condition of the Device 8 Dispose of the Device and its components according to the application local regulations No special requiremen...

Страница 7: ...d lower Cu size OF the Device adult s for upper arm circle from 25 to 36 cm Weight without package case g 332 Dimensions package mm 115 x 185 x 75 Year of manufacture Year the manufacture is given in...

Страница 8: ...G Zawila Street 30 390 Krak w Poland Sales O ce phone 48 12 2684746 12 2684747 fax 48 12 268 47 53 E mail biuro littledoctor pl www LittleDoctor pl Authorized Representative in the EU Little Doctor Eu...

Страница 9: ...ia prawid owego pomiaru nale y pami ta e CI NIENIE T TNICZE PODLEGA SILNYM WAHANIOM NAWET W KR TKIM PRZEDZIALE CZASOWYM Warto ci nienia t tniczego krwi zale y od wielu czynnik w Zwykle jest ona ni sza...

Страница 10: ...dnej dla pacjenta w temperaturze pokojowej Na godzin przed pomiarem nie nale y spo ywa posi k w a w ci gu 1 5 2 godzin nie pali nie pi napoj w wzmacniaj cych i alkoholu 5 Dok adno pomiaru ci nienia t...

Страница 11: ...j r ce jest utrudnio ny mo na dokona go na prawej Nale y pami ta e wynik mo e si r ni o 5 10 mmHg a w niekt rych przypadkach nawet wi cej Rys 4 3 Owi mankiet tak aby jego dolna kraw d znajdowa a si w...

Страница 12: ...CA A R KA LU NO LE A A NA STOLE I NIE PORUSZ A SI PROCEDURA POMIARU 1 Za o y stetoskop na uszy Zamkn zaw r na gruszce przekr caj c go w kierunku zgodnym z ruchem wskaz wek zegara ciskaj c gruszk pompo...

Страница 13: ...nktu serwisowego w celu sprawdzenia technicznego stanu urz dzenia 8 Utylizacja urz dzenia przeprowadzana jest wed ug zasad obowi zuj cych obecnie w danym kraju Specjalne warunki utylizacji nie zosta y...

Страница 14: ...szka LD S051 1 szt 5 Wlot powietrza LD S056 1 szt 6 Zaw r LD S054 1 szt 7 Etui LD S059 1 szt 8 Instrukcja obs ugi 1 szt 9 Karta gwarancyjna 1 szt 10 Opakowanie 1 szt DOK ADNO POMIARU Produkcja urz dze...

Страница 15: ...enia cm Materia Wk adka powietrzna C1N dla noworodk w 7 12 bawe na TPU LD S01N bez pier cienia C1I dla niemowl t 11 19 bawe na TPU LD S01I C1C dla dzieci N1C dla dzieci 18 26 bawe na TPU nylon TPU LD...

Страница 16: ...Pte Ltd Little Doctor International S Pte Ltd 2016 LITTLE DOCTOR INTERNATIONAL S PTE LTD Yishun Central P O Box 9293 Singapore 917699 Fax 65 62342197 E mail ld singaporemail com Little Doctor Europe...

Отзывы: