LATS (3 CCT) TRACK WIRING DIAGRAM
CATALOG # :
Keep these instructions in a safe place for future use/reference.
Page 5 of 5
Important: Please read and understand all instructions
completely before installing this fixture.
WARNING: Fixture installation (and use) and all electrical connections must be in accordance with
local and National Electrical Codes (N.E.C.) rules, regulations and standards. If you are unfamiliar
with installing fixture(s), accessories and/or electrical wiring have a qualified licensed electrician
install this fixture for you. Fixture should be installed by a qualified electrician.
WARNING: RISK OF SHOCK. House electric current can cause painful shock or serious injury.
WARNING: Always disconnect power before fixture installation, wiring, or maintenance.
WARNING: Before starting the wire connections, disconnect the power by turning off the circuit breaker
or removing the fuse at the fuse panel. Turning the power off using the light switch is not sufficient to
prevent electrical shock.
This luminaire must be connected with supply wire/conductors rated at 90°C. Most dwellings built
before 1985 have supply wire rated at 60°C; consult a qualified electrician before installing.
WARNING: Before service insure fixture is cool to touch.
WARNING: Check fixture for input voltage before connecting power to fixture.
WARNING: RISK OF SHOCK. Fixture is suitable for dry locations (unless otherwise stated on fixture,
Liton's web site or other installations. Also for use with covered ceiling mount.
WARNING: Do not install any fixture or assembly (etc.) closer than 6" from any curtain, or similar
combustible material.
Fixture must be installed on a circuit protected by Ground Fault Circuit Interrupter
(GFCI).
Fixtures that are not LED:
For installing lampholder, make sure to refer to other instructions within your fixture, as
required. For installing lamps please refer to your lamp manufacturers’ instructions.
LED Fixtures:
RELAMPING:
Return fixture to Liton for servicing/replacing LED and LED drivers, as required.
Install LED fixture(s)/LED driver(s) only on their own circuit. Do not mix any other
products (Incandescent, Compact Fluorescent, H.I.D. products/fixtures, etc...) with LED
fixture(s)/LED driver(s) on a single circuit.
Do not use any other electrical equipment (example: surge protector photocell, etc.) that
is not (rated) for use with LED fixture(s)/LED driver(s) on the same circuit as LED
fixture(s)/LED driver(s).
Install remote surge protector(s) (by others, goes on the circuit with nothing between the
surge protector and the LED fixture(s)/LED driver(s)), if the fixture is not already
installed with a surge protector, to help remove power surges that may harm LED
fixture(s), appropriate for the installation. Periodically check and make sure that your
remote surge protector(s) are in good working order.
LP3 Series Track System with 3 Circuit Track (3 CCT/1N) Only
LCALDJ2
- LP3 Series Track Mount Connector with 3 Circuit, 1 Neutral (3CCT / 1N) Track
FOR USE WITH LITON LP3 SERIES TRACK SYSTEM ONLY
SAVE THESE INSTRUCTIONS
01182019
FIG. 3
FIG. 2
FIG. 1
L = Black Wire
1
L = Black Wire
3
L = Red Wire
2
N = White Wire
1-1/16"
L
2
L
3
L
N
1
1-1/4"
1-1/8"
1-3/8"
WIRING (POLARITY) DIAGRAM
L
2
20A
N
Ph
2
L
N
THREE-PHASE, THREE-SWITCHES (60A)
3
L
1
20A
Ph
3
20A
Ph
1
SWITCH OR DIMMER
CIRCUIT 2
POSITION
CIRCUIT 1
POSITION
CIRCUIT 3
POSITION
LEVER
AT THE
SIDE
KNOB “OFF” AT THIS
LOCATION
TURN LEVER
TO THE END
PUSH
INTO
TRACK
3 CIRCUIT TRACK (3
TURN KNOB TO
DESIRED
CIRCUIT NO.
KNOB
EXTENSION
ADAPTER
GUIDE
TRACK HEAD
CONNECTOR
(3 CCT )
TRACK HEAD CONNECTOR
“OFF” POSITION
TRACK HEAD CONNECTOR CIRCUIT 1, 2 & 3 POSITION
TRACK HEAD
CONNECTOR (3 CCT)
Note: If supply wires are short,
use direct Power Supply
Source and connect to relative
terminal as instructed
SURFACE TRACK
WITH 3 CIRCUITS &
1 NEUTRAL
(3 CCT / 1N)
3/16" x 3" LONG
TOGGLE BOLTS
(SUPPLIED)
Ø 5/8"
HOLE
GUIDE LUG
ACCESS
HOLES
GROUND WIRE (GREEN)
LOCK
SCREW
LINE 1 WIRE (BLACK)
LINE 2 WIRE (RED)
LINE 3 WIRE (BLACK)
NEUTRAL WIRE (WHITE)
CONNECT
WIRES TO
JUNCTION BOX
WITH FLEX
CONDUIT
LIVE END, RIGHT SIDE
(POWER FEED. CAT # LP3941
SHOWN). ALSO AVAILABLE FOR
LEFT SIDE (CAT #LP3942)
Track Fixture Installation (120V AC):
WARNING: Always disconnect power before fixture installation, wiring or maintenance!
1. Remove the cover of the Live End (Power Feed, right or left) to expose wires (FIG. 1).
2. With the power off, connect the Cable to the Relative Terminal (See Wiring Diagram above).
3. Insert the Live End (Power Feed, right side shown FIG. 1) into the 3 Circuit Track (3 CCT
TRACK) using the Guide Lug (FIG. 1).
4. Fasten the Lock Screw till it fully locks with the Track (FIG. 1).
5. Make Ø 5/8" holes in the wall or ceiling matching the Toggle Bolts holes are in the Track. Use
Track as template/guide to mark hole locations on ceiling or wall.
6. Install, and secure, the 3 Circuit Track (3 CCT TRACK) to ceiling or wall using the supplied
3/16" x 3" long Toggle Bolts (FIG. 1).
7. On the fixtures 3 circuit (3 CCT) Tack Head Connector make sure the Lever is on the side and
the Knob is in the "OFF" position" (FIG. #2). Do NOT install the fixture track head into the
track if the Track Head Connector is NOT in this position.
8. Align the fixture Track Head to the 3 CCT Track so that the Adapter Guide is opposite side of
the Track Extension (FIG. 2).
9. Install the fixtures Track Head Connector into the Track (FIG. 2) at the desired location and
turn the Lever on the Track head to the end of the Track Head (FIG. 3).
10. Turn the Track Head Knob to the desired circuit position (FIG. 3).
11. To remove the fixture Track Head Connector from the Track disconnect power (see above
WARNING), and reverse steps 9 and 10 above by turning the Knob to the "OFF" position and
then push Lever to the side of the Track Head Connector (FIG. 2).
The Liton Architectural Track
Series are equipped with four
copper conductors, three for live
circuits and one for neutral. The
body of the track serves as the
ground connection. The copper
conductors have a circular cross
section, and are .088 inches in
diameter. Therefore, these
conductors are approximately 20
percent larger in area than
12AWG; and this extra gauge
provides additional margin for
loading of the neutral conductor.
SURFACE TRACK AND LIVE END (RIGHT SIDE) SHOWN