INSTALLATION INSTRUCTIONS

5461 W. Jefferson Blvd. Los Angeles, CA 90016 

  P. 800-515-4880 

 F. 800-972-4880 

 www.liton.com         Product specifications subject to change without notice.

L   I   G   H   T   I   N   G

LATS (3 CCT) TRACK WIRING DIAGRAM

CATALOG # :

Keep these instructions in a safe place for future use/reference.

Page 5 of 5

Important: Please read and understand all instructions 

completely before installing this fixture.

WARNING: Fixture installation (and use) and all electrical connections must be in accordance with 
local and National Electrical Codes (N.E.C.) rules, regulations and standards. If you are unfamiliar 
with installing fixture(s), accessories and/or electrical wiring have a qualified licensed electrician 
install this fixture for you. Fixture should be installed by a qualified electrician.

WARNING:  RISK OF SHOCK. House electric current can cause painful shock or serious injury.  
WARNING: Always disconnect power before fixture installation, wiring, or maintenance.  
WARNING: Before starting the wire connections, disconnect the power by turning off the circuit breaker 
or removing the fuse at the fuse panel. Turning the power off using the light switch is not sufficient to 
prevent electrical shock.

This luminaire must be connected with supply wire/conductors rated at 90°C. Most dwellings built 
before 1985 have supply wire rated at 60°C; consult a qualified electrician before installing.

WARNING: Before service insure fixture is cool to touch.
WARNING: Check fixture for input voltage before connecting power to fixture.

WARNING: RISK OF SHOCK. Fixture is suitable for dry locations (unless otherwise stated on fixture, 
Liton's web site or other installations. Also for use with covered ceiling mount.

WARNING: Do not install any fixture or assembly (etc.) closer than 6" from any curtain, or similar 
combustible material.

Fixture must be installed on a circuit protected by Ground Fault Circuit Interrupter 
(GFCI).

Fixtures that are not LED:
For installing lampholder, make sure to refer to other instructions within your fixture, as 
required. For installing lamps please refer to your lamp manufacturers’ instructions.

LED Fixtures:
RELAMPING:
Return fixture to Liton for servicing/replacing LED and LED drivers, as required.

Install LED fixture(s)/LED driver(s) only on their own circuit. Do not mix any other 
products (Incandescent, Compact Fluorescent, H.I.D. products/fixtures, etc...) with LED 
fixture(s)/LED driver(s) on a single circuit.

Do not use any other electrical equipment (example: surge protector photocell, etc.) that 
is not (rated) for use with LED fixture(s)/LED driver(s) on the same circuit as LED 
fixture(s)/LED driver(s).

Install remote surge protector(s) (by others, goes on the circuit with nothing between the 
surge protector and the LED fixture(s)/LED driver(s)), if the fixture is not already 
installed with a surge protector, to help remove power surges that may harm LED 
fixture(s), appropriate for the installation. Periodically check and make sure that your 
remote surge protector(s) are in good working order.

LP3 Series Track System with 3 Circuit Track (3 CCT/1N) Only

LCALDJ2

 - LP3 Series Track Mount Connector with 3 Circuit, 1 Neutral (3CCT / 1N) Track

FOR USE WITH LITON LP3 SERIES TRACK SYSTEM ONLY

SAVE THESE INSTRUCTIONS

01182019

FIG. 3

FIG. 2

FIG. 1

L  = Black Wire

1

L  = Black Wire

3

L  = Red Wire

2

N  = White Wire

1-1/16"

L

2

L

3

L
N

1

1-1/4"

1-1/8"

1-3/8"

WIRING (POLARITY) DIAGRAM

L

2

20A 

N

Ph

2

L

N

THREE-PHASE, THREE-SWITCHES (60A)

3

L

1

20A 

Ph

3

20A 

Ph

1

SWITCH OR DIMMER

CIRCUIT 2
POSITION

CIRCUIT 1
POSITION

CIRCUIT 3
POSITION

LEVER
AT THE 
SIDE

KNOB “OFF” AT THIS 

LOCATION

TURN LEVER 
TO THE END

PUSH 

INTO 

TRACK

3 CIRCUIT TRACK (3 

TURN KNOB TO 
DESIRED 
CIRCUIT  NO.

KNOB

EXTENSION

ADAPTER

GUIDE

TRACK HEAD
CONNECTOR 
(3 CCT )

TRACK HEAD CONNECTOR 

“OFF” POSITION

TRACK HEAD CONNECTOR CIRCUIT 1, 2 & 3 POSITION

TRACK HEAD 

CONNECTOR (3 CCT)

Note: If supply wires are short,
use direct Power Supply
Source and connect to relative
terminal as instructed

SURFACE TRACK 

WITH 3 CIRCUITS & 

 1 NEUTRAL

(3 CCT / 1N)

3/16" x 3"  LONG 

TOGGLE BOLTS

(SUPPLIED)

Ø 5/8" 

HOLE

GUIDE LUG

ACCESS

HOLES

GROUND WIRE (GREEN)

LOCK
SCREW

LINE 1 WIRE (BLACK)

LINE 2 WIRE (RED)

LINE 3 WIRE (BLACK)

NEUTRAL WIRE (WHITE)

CONNECT 
WIRES TO 
JUNCTION BOX 
WITH FLEX 
CONDUIT

LIVE END, RIGHT SIDE
(POWER FEED. CAT # LP3941 
SHOWN). ALSO AVAILABLE FOR 
LEFT SIDE (CAT #LP3942)

Track Fixture Installation (120V AC):

WARNING: Always disconnect power before fixture installation, wiring or maintenance!
1. Remove the cover of the Live End (Power Feed, right or left) to expose wires (FIG. 1).
2. With the power off, connect the Cable to the Relative Terminal (See Wiring Diagram above).
3. Insert the Live End (Power Feed, right side shown FIG. 1) into the 3 Circuit Track (3 CCT 
TRACK) using the Guide Lug (FIG. 1).
4. Fasten the Lock Screw till it fully locks with the Track (FIG. 1).
5. Make Ø 5/8" holes in the wall or ceiling matching the Toggle Bolts holes are in the Track. Use 
Track as template/guide to mark hole locations on ceiling or wall.
6. Install, and secure, the 3 Circuit Track (3 CCT TRACK) to ceiling or wall using the supplied 
3/16" x 3" long Toggle Bolts (FIG. 1).
7. On the fixtures 3 circuit (3 CCT) Tack Head Connector make sure the Lever is on the side and 
the Knob is in the "OFF" position" (FIG. #2). Do NOT install the fixture track head into the 
track if the Track Head Connector is NOT in this position.
8. Align the fixture Track Head to the 3 CCT Track so that the Adapter Guide is opposite side of  
the Track Extension (FIG. 2).
9. Install the fixtures Track Head Connector into the Track (FIG. 2) at the desired location and 
turn the Lever on the Track head to the end of the Track Head (FIG. 3).
10. Turn the Track Head Knob to the desired circuit position (FIG. 3).
11. To remove the fixture Track Head Connector from the Track disconnect power (see above 
WARNING), and reverse steps 9 and 10 above by turning the Knob to the "OFF" position and 
then push Lever to the side of the Track Head Connector (FIG. 2).

The Liton Architectural Track 
Series are equipped with four 
copper conductors, three for live 
circuits and one for neutral. The 
body of the track serves as the 
ground connection. The copper 
conductors have a circular cross 
section, and are .088 inches in 
diameter. Therefore, these 
conductors are approximately 20 
percent larger in area than 
12AWG; and this extra gauge 
provides additional margin for 
loading of the neutral conductor.

SURFACE TRACK AND LIVE END (RIGHT SIDE) SHOWN 
FOR CLARITY. OTHER LP3 ACCESSORIES NOT SHOWN.