
CATALOG # :
SAVE THESE INSTRUCTIONS
L I G H T I N G
INSTALLATION INSTRUCTIONS
Page 1 of 5
01182019
LCALDJ2 SURFACE (CEILING MOUNT)
5461 W. Jefferson Blvd. Los Angeles, CA 90016
• P. 800-515-4880 • F. 800-972-4880 • www.liton.com Product specifications subject to change without notice.
FIG. 1
Keep these instructions in a safe place for future use/reference.
Important: Please read and understand all instructions
completely before installing this fixture.
WARNING: Fixture installation (and use) and all electrical connections must be in accordance with
local and National Electrical Codes (N.E.C.) rules, regulations and standards. If you are unfamiliar
with installing fixture(s), accessories and/or electrical wiring have a qualified licensed electrician
install this fixture for you. Fixture should be installed by a qualified electrician.
WARNING: RISK OF SHOCK. House electric current can cause painful shock or serious injury.
WARNING: Always disconnect power before fixture installation, wiring, or maintenance.
WARNING: Before starting the wire connections, disconnect the power by turning off the circuit breaker
or removing the fuse at the fuse panel. Turning the power off using the light switch is not sufficient to
prevent electrical shock.
This luminaire must be connected with supply wire/conductors rated at 90°C. Most dwellings built
before 1985 have supply wire rated at 60°C; consult a qualified electrician before installing.
WARNING: Before service insure fixture is cool to touch.
WARNING: Check fixture for input voltage before connecting power to fixture.
WARNING: RISK OF SHOCK. Fixture is suitable for dry locations (unless otherwise stated on fixture,
Liton's web site or other installations). Also for use with covered ceiling mount.
Fixture must be installed on a circuit protected by Ground Fault Circuit Interrupter (GFCI).
WARNING: Do not install any fixture or assembly (etc.) closer than 6" from any curtain,
or similar combustible material.
Fixture must be installed on a circuit protected by Ground Fault Circuit Interrupter
(GFCI).
RELAMPING:
Return fixture to Liton for servicing/replacing LED and LED drivers, as required.
Install LED fixture(s)/LED driver(s) only on their own circuit. Do not mix any other
products (Incandescent, Compact Fluorescent, H.I.D. products/fixtures, etc...) with LED
fixture(s)/LED driver(s) on a single circuit.
Do not use any other electrical equipment (example: surge protector photocell, etc.) that
is not (rated) for use with LED fixture(s)/LED driver(s) on the same circuit as LED
fixture(s)/LED driver(s).
Install remote surge protector(s) (by others, goes on the circuit with nothing between the
surge protector and the LED fixture(s)/LED driver(s)), if the fixture is not already
installed with a surge protector, to help remove power surges that may harm LED
fixture(s), appropriate for the installation. Periodically check and make sure that your
remote surge protector(s) are in good working order.
FIXTURE INSTALLATION (CEILING MOUNT ONLY)
1. As needed remove Mounting Plate Assembly (MPA) from Housing Assy (FIG 1) by removing the two (2) M3 screws on the side of the
fixture.
2. Mounting plate Assembly fits onto a 4" octagonal junction box (J-BOX) or other J-Boxes that have a 3-1/2” hole/screw spacing (see
above dimensions). Other j-boxes may also fit. Make sure J-BOX threaded holes will fit MPA holes.
3. Install wiring in 4" octagonal J-BOX (or other j-box) in ceiling, as needed.
4. Connect the power supply wiring from J-BOX to fixture wiring from LED driver in j-box. See "Wiring" instructions below.
5. Secure Mounting Plate Assembly (with LED driver) on j-box (by others), LED driver fits in 4" octagonal j-box, with appropriate
hardware (by others) (FIG 1). Keep wires from Housing Assembly to Mounting Plate Assembly attached. Do NOT pull on wires from
Housing Assembly to LED driver.
6. Align the two (2) tabs on the Mounting plate to the slots in the top of the Housing Assembly (FIG. 1).
7. Tighten M3 screw with #1 screw driver in housing until set screw is flush with outside of housing. Do not over tighten screws.
WIRING
NOTE: Check fixture for input voltage before connecting power to fixture. Connect wiring in j-box. For dimming information (wiring
diagrams, chart, etc.) see LCALDJ2 website page.
1. Connect ground wire (green or bare copper/aluminum) from the supply circuit to the ground wire (green or bare copper) / screw /
connector from the fixture.
2. Connect the neutral (common) wire from the power supply circuit to the neutral wire from the fixture.
3. Connect the main voltage supply wire (line/lead) from the power supply to the line (lead) wire from the fixture.
4. Secure connection using UL Listed wire nuts/connectors and then with UL Listed Electrical tape (by others), as required, appropriate
for the connection.
RELAMPING:
Return fixture to Liton for servicing/replacing LED and LED drivers.
CHANGING REFLECTOR (FIG. 4)
1. Remove fixture from mounting surface. Point fixture (A) downward and then lightly press and turn Trim (D) counterclockwise to
unscrew and remove Trim (D) with Glass (C) and Reflector (B) from fixture housing (A).
2. Twist Reflector (B) until tab aligns with Trim (D). Push up and remove Reflector (B) and Glass (C) (as needed) from Trim (D).
3. Replace Reflector (B) with a new Reflector and reverse procedure in steps 1 and 2 above to install trim snug (finger tight) in
housing. Do not over tighten trim in houisng.
WARNING: Always disconnect power before fixture
installation, wiring, or maintenance.
LCALDJ2 HOUSING
ASSEMBLY (1)
MOUNTING PLATE ASSEMBLY (MPA)
• #1 and #2 Phillips Head
Screwdriver
• Wire Connectors
• Hardware (screws, nuts, etc.)
• DO NOT USE POWER TOOLS.
ONLY USE HAND TOOLS.
MOUNTING PLATE
ASSEMBLY (MPA)
(With LED Driver)
(1)
M3 X 6mm LONG
FLAT HEAD SCREWS
(2)
3-1/2”
Ø4-3/4”
(HOLES FOR
WIRE EXIT)
(2)
COUNTERSINK
HOLES
(FOR (2)
#8 FLAT HEAD
SCREWS, BY
OTHERS)
Components / Parts (LCALDJ2)
Tools Required
Components Dimensions
TABS
FIG. 2
TURN TRIM TILL TABS ALIGN ON TRIM
AND REFLECTOR
D
A
B
C
TAB
TAB
TABS ALIGNED
TABS NOT
ALIGNED
3-1/2”
LCALDJ2 HOUSING
ASSEMBLY
MOUNTING PLATE ASSY
(With LED Driver)
M3 X 6mm LONG
FLAT HEAD SCREWS (2)
8-32 FLAT HEAD SCREWS (2)
(BY OTHERS)
4“ OCTAGONAL J-BOX
(BY OTHERS)
TILTS 85° MAX.
ROTATES 325° MAX.
AFTER INSTALLATION
TILT AND ROTATE
FIXTURE HEAD TO
PROPER
ORIENTATION
(FIXTURE
HEAD)