background image

INSTALLATION INSTRUCTIONS

JCBL Series Instructions

©2016 Acuity Brands Lighting, Inc.    Rev 10/16   P4130    pg 1 of 7

One Lithonia Way, Conyers, GA 30012 
Phone: 800-315-4963   www.lithonia.com

•  To reduce the risk of death, personal injury or property damage from fire, electric shock,  

  falling parts, cuts/abrasions, and other hazards please read all warnings and instructions  

  included with and on the fixture box and all fixture labels. 
•  Before installing, servicing, or performing routine maintenance upon this equipment,  

  follow these general precautions.
•  Installation and service of luminaires should be performed by a qualified licensed electrician
•  Maintenance of the luminaires should be performed by person(s) familiar with the  

  luminaires’ construction and operation and any hazards involved. Regular fixture  

  maintenance programs are recommended. 
•  It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of  

  cleaning will depend on ambient dirt level and minimum light output which is acceptable  

  to user. Refractor/lens should be washed in a solution of warm water and any mild, non- 

  abrasive household detergent, rinsed with clean water and wiped dry. Should optical  

  assembly become dirty on the inside, wipe refractor/lens and clean in above  

  manner, replacing damaged gaskets as necessary. 
•  DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so  

  that no parts should have been damaged during transit. Inspect to confirm. Any part  

  damaged or broken during or after assembly should be replaced.
•  Recycle: For information on how to recycle LED electronic products, please visit  

 www.EPA.gov
•  These instructions do not purport to cover all details or variations in equipment nor to  

  provide every possible contingency to meet in connection with installation, operation, or  

  maintenance. Should further information be desired or should particular problems arise  

  which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter  

  should be referred to Acuity Brands Lighting, Inc.

READ AND FOLLOW ALL SAFETY INSTRUCTIONS!

SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

IMPORTANT SAFETY INSTRUCTIONS

         CAUTION: RISK OF PRODUCT DAMAGE
•  Never connect components under load. 
•  Do not mount or support these fixtures in a manner that can cut the outer jacket or  

  damage wire insulations.
•  Never connect an LED product to an unapproved dimmer pack. Contact ABL directly for any  

  dimmers not specifically recommended for the product. 
•  Unless individual product specifications deem otherwise: Allow for some volume of  

  airspace around fixture. Avoid covering LED fixtures with insulation, foam, or other material  

  that will prevent convection or conduction cooling. 
•  Unless individual product specifications deem otherwise: Maximum ambient temperature in  

  90ºC. Do not operate fixture at temperatures higher than this.
•  Unless individual product specifications deem otherwise: Never mount in places where  

  fixture will be exposed to rain, high humidity, extreme temperature changes or restricted  

 ventilation.
•  LEDs are polarity Sensitive. Ensure proper Polarity before installation.
•  Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding  

  equipment must be worn during all installation or servicing of the unit.
•  Do not touch individual electrical components as this can cause ESD, shorten lamp life,  

  or alter performance. 

• There are no user serviceable parts insode the unit. Do not rewire, configure, or modify the  

  unit or attempt any repairs yourself. Additionally, field replacement of the LED assembly or  

  lamps is not allowed by UL standards at this time. In the unlikely event your unit may  

  require service, stop using the unit immediately and contact an ABL representative.

All luminaires that contain electronic devices that generate frequencies above 9kHz 

from any component within the luminaire comply with one of the following Part 15 of 

the FCC Rules.  Operation is subject to the following two conditions:
  (1) This device may not cause harmful interference 

  (2)  This device must accept any interference recieved, including  

   

interference that may cause undesired operation.

This device complies with Part 18 of the FCC Rules, but may cause interference with 

cordless and cell phones, radios, televisions, and other electronic devices. To correct 

the problem move the device away from the luminaire or lug into a different outlet. 

This product may cause interference to radio equipment and should not be installed 

near maritime safety communications equipment or other critical navigation or  

communications equipment operating between 0.45-30MHz.

Failure to follow any of these instructions could void product warranties. For a 

complete listing of product Terms and Conditions, please visit  

www.acuitybrands.com
OUR BRANDS
Indoor/Outdoor:
 Lithonia Lighting, Carandinim Holophane, RELOC 

Indoor Lighting: Gotham, Mark Architectural Lighting,  Peerless, Renaissance 

Lighting, Winona Lighting 

Outdoor Lighting: American Electric Lighting, Antique Street Lamps, Hydrel, Tersen 

Controls: DARK TO LIGHT, Lighting Control & Design, ROAM, Sensor Switch, 

Synergy
Acuity Brands Lighting, Inc.  assumes no responsibility for claims arising out 

of improper or careless installation or handling of its products.

•  Disconnect or turn off power before installation or servicing.
•  Verify that supply voltage is correct by comparing it with the luminaire  

  label information.
•  Make all electrical and grounded connections in accordance with the National  

  Electrical Code (NEC) and any applicable local code requirements.
•  All wiring connections should be capped with UL approved recognized 

  wire connectors.

WARNING RISK OF ELECTRIC SHOCK

•  Wear gloves and safety glasses at all times when removing luminaire from carton,   

  installing, servicing or performing maintenance.
•  Avoid direct eye exposure to the light source while it is on.

CAUTION RISK OF INJURY

•  Allow lamp/fixture to cool before handling. Do not touch enclosure or light source.
•  Do not exceed maximum wattage marked on luminaire label.
•  Follow all manufacturer’s warnings, recommendations and restrictions for: driver 

  type, burning position, mounting locations/methods, replacement and recycling.

WARNING RISK OF BURN

•  Keep combustible and other materials that can burn, away from lamp/lens.
•  Do not operate in close proximity to persons, combustible materials or substances 

  affected by heat or drying.

CAUTION RISK OF FIRE

Содержание JCBL Series

Страница 1: ...larity before installation Electrostatic Discharge ESD ESD can damage LED fixtures Personal grounding equipment must be worn during all installation or servicing of the unit Do not touch individual electrical components as this can cause ESD shorten lamp life or alter performance There are no user serviceable parts insode the unit Do not rewire configure or modify the unit or attempt any repairs y...

Страница 2: ...es while making connection to AC power source d If dimming is required use the provided dimming leads Dim and Dim leads If dimming is not required cap off any unused leads 5 Balance the fixture by loosening the two screws on the top hub see Figure 4 and sliding the hub Tighten screws after balancing If not enough movement is achieved with the top hub to balance the fixture the J Box can also provi...

Страница 3: ...TALLATION INSTRUCTIONS JCBL Series Instructions 2016 Acuity Brands Lighting Inc Rev 10 16 P4130 pg 3 of 7 One Lithonia Way Conyers GA 30012 Phone 800 315 4963 www lithonia com Figure 6 Screws Four Total Locking Screw Figure 7 Driver Compartment Figure 8 Figure 9 Knock out Screw Dimming Leads Cover Strain Relief Wire Not supplied ...

Страница 4: ...5 Highbay lens Best choice for 15 to 45 ft 4 57 to 13 72 m mounting heights Excellent detection for large motion e g walking up to 35 feet 10 6 m mounting height Excellent detection of extra large motion e g forklifts up to 45 feet 13 72 m mounting height Lowbay lens Best choice for large motion detection e g walking Provides 24 feet 8 53 m radial coverage when mounted at 9 feet 2 74 m Detection r...

Страница 5: ...t before it starts operating under the new setting The sensor can be programmed for Function 2 Occupancy Time Delay This function sets the length of time the fixture stays ON or on High Light Output after the last time it sensed occupancy Function 4 Minimum On time This is a safety feature to extend the life of certain light sources It prevents the fixture from turning On and Off repeatedly in a s...

Страница 6: ...n 9 times Maintain current 1 Restore defaults 2 11 Dimming Level Level the fixture will dim to after Occupancy Time Delay Function 2 has expired Press button 11 times N A 1 10 2 20 3 30 4 40 5 50 6 60 7 70 8 80 9 90 10 100 11 12 Switch Button Mode Use for testing wiring When enabled user can manually switch the relay with the push button Press button 12 times Disabled 1 Enabled 2 15 Dim to Off Occ...

Страница 7: ...witched power source After fixture has been wired and power restored the battery test switch should be illuminated This means that the battery controller is receiving power and charging the battery Push the test button to confirm the fixture switches to battery mode A single LED will light up delivering approximately 1400 lumens After initial test let the fixture charge for at least 48 hours prefe...

Страница 8: ...Interior Exterior Lithonia Lighting Carandini Holophane RELOC Sistemas de iluminación para interior Gotham Mark Architectural Lighting Peerless Renaissance Lighting Winona Lighting Sistemas de iluminación para exterior American Electric Lighting Antique Street Lamps Hydrel Tersen Controles DARK TO LIGHT Lighting Control Design ROAM Sensor Switch Synergy Acuity Brands Lighting Inc no se hace respon...

Страница 9: ...el NEC al hacer las conexiones a la fuente de energía de CA d Si se necesita atenuación use los alambres de atenuación proporcionados Alambres Dim y Dim Si no se requiere la atenuación tape los alambres no usados 5 Balancee el accesorio aflojando los dos tornillos en el centro superior Ver Figura 4 y deslizando el centro Apriete los dos tornillos después de balancear Si no se logra suficiente movi...

Страница 10: ... com Centro Caja de Empalmes Puerta de Conexiones Figura 4 Tornillos para Balancear el Accesorio Tornillo Tornillos de Montaje de la Caja de Empalmes Cuatro en Total Figura 5 Tornillo de Fijación Figura 6 Tornillos Quatro en Total Tornillo de Fijación Figura 7 Compartimiento del Impulsador Troquel Tornillo Figura 8 Figura 9 Cables de Atenuación Tapa Pasacables y Cable No proporcionados ...

Страница 11: ...celente detección para movimientos grandes por ejemplo caminar en monturas altas de hasta 35 pies 10 6 m Excelente detección para movimientos extra grandes por ejemplo montacargas en monturas altas de hasta 45 pies 13 72 m Lente de Montura Baja La mejor elección para detección de movimientos grandes por ejemplo caminar Proporciona una cobertura radial de 24 pies 8 53 m cuando se monta a 9 pies 2 7...

Страница 12: ... antes de que empiece a funcionar con la nueva configuración El sensor se puede configurar para Función 2 Demora de Tiempo de Ocupación Esta función configura el tiempo en que el accesorio se mantiene ENCENDIDO o en Salida de Luz Alta después de la última vez que detectó la ocupación Función 4 Tiempo de Encendido Mínimo Esta es una característica de seguridad para extender la vida útil de algunas ...

Страница 13: ... de fábrica Configuraciones sombreadas en gris Presione el botón 9 veces Mantener el actual 1 Restaurar por defecto 2 11 Nivel de Atenuación El nivel de atenuación a la que llegará el accesorio cuando expire la Demora de Tiempo de Ocupación Función 2 Presione el botón 11 veces N A 1 10 2 20 3 30 4 40 5 50 6 60 7 70 8 80 9 90 10 100 11 12 Modo de Botón de Conmutación Use para probar las conexiones ...

Страница 14: ...ccesorio pueden conectarse a una fuente de energía conmutada o no conmutada Después de que el accesorio haya sido conectado y la energía restaurada el interruptor de prueba de la batería debe de estar encendido Esto indica que el controlador de la batería está recibiendo energía y cargando la batería Presione el botón para confirmar que el accesorio cambie al modo de batería Se encenderá un LED pr...

Страница 15: ...ng Carandini Holophane RELOC Éclairage intérieur Gotham Mark Architectural Lighting Peerless Renaissance Lighting Winona Lighting Éclairage extérieur American Electric Lighting Antique Street Lamps Hydrel Tersen Commandes d éclairage DARK TO LIGHT Lighting Control Design ROAM Sensor Switch Synergy Acuity Brands Lighting Inc décline toute responsabilité pour les réclama tions résultant d une instal...

Страница 16: ...aux et du NEC tout en assurant le raccordement à la source d alimentation en C A d Si un système d atténuation est nécessaire utilisez les conducteurs de gradateur prévus conducteurs Dim et Dim Si aucun système d atténuation n est nécessaire chapeautez tous les fils inutilisés 5 Équilibrez le luminaire en desserrant les deux vis sur le manchon supérieur voir la Figure 4 et en faisant coulisser l e...

Страница 17: ... www lithonia com Manchon Boîtier de connexion de câblage Porte de câblage Figure 4 Vis d équilibrage du luminaire Vis Vis de fixation de Boîtier de connexion Quatre en tout Figure 5 Vis de blocage Figure 6 Vis Quatre en tout Vis de blocage Figure 7 Compartiment de pilote Découpe Vis Figure 8 Figure 9 Conducteurs de gradation Carter Passe fils de carter et fil non fournis ...

Страница 18: ...xcellente détection pour les mouvements importants par exemple marche jusqu à 10 6 m de hauteur de fixation Excellente détection de mouvements de très grande ampleur par exemple chariots élévateurs jusqu à 13 72 m de hauteur de fixation Objectif faible hauteur Le choix le mieux adapté à la détection de mouvements amples par exemple marche Permet une couverture radiale de 8 53 m lorsqu il est monté...

Страница 19: ...ence à fonctionner sous la nouvelle configuration Le capteur peut être programmé pour Fonction 2 Délai d allumage après occupation Cette fonction établit la durée pendant laquelle le luminaire demeure allumé ou sur l intensité lumineuse élevée après la dernière fois où une présence a été détectée Fonction 4 Durée minimale d allumage Ceci est une caractéristique de sécurité permettant de prolonger ...

Страница 20: ...d usine réglages grisés Appuyez 9 fois sur le bouton Maintenez les valeurs actuelles 1 Rétablir les valeurs implicites 2 11 Niveau d atténuation Niveau auquel le luminaire sera atténué après l expiration du Délai d illumination après détection de présence Fonction 2 Appuyez 11 fois sur le bouton N A 1 10 2 20 3 30 4 40 5 50 6 60 7 70 8 80 9 90 10 100 11 12 Mode de bouton commutateur Utilisez pour ...

Страница 21: ...trée du luminaire standard peuvent être reliés à une source d alimentation commutée ou non Une fois le luminaire câblé et l alimentation rétablie le commutateur de test de la batterie doit être illuminé Cela signifie que le contrôleur de batterie est alimenté et charge la batterie Poussez le bouton de test pour confirmer que les commutateurs de luminaire sont sur le mode batterie Une LED unique s ...

Страница 22: ... of the Guard to the Pendant Mount Junction Box Slide the top half of the full wire guard over the Pendant Mount Junction Box Align the holes in the Pendant Mount Junction Box with the two of the holes in the guard mounting plate Drive the screws provided through these holes into the Pendant Mount Junction Box Assemble the Wire guard Attach the bottom half of the wire guard and close SAVE THESE IN...