page 5
6. Wiring.
wall control
wall control
back plate
back plate
screw
back plate screw
safety cable
wood screw
and washer
hanging bar
wood joist
black
white
black
green/ground
bare/ground
from fan
white
*
black
black
AC IN
black
AC IN
black
AC TO FAN
black
AC TO FAN
black
*
wall control
wire
from
ceiling
Important
:
Be sure outlet box is properly
grounded or that a ground wire (
GREEN
or
Bare) is present.
Make sure all electrical connections comply
with Local Codes or Ordinances and the
National Electrical Code. If you are unfamiliar
with electrical wiring or if the wires in the
house/building are different colors than those
mentioned below, please consult with a
qualified electrician.
Connect
BLACK
wire from fan to
BLACK
wire from ceiling. Connect
WHITE
wire from
fan to
WHITE
wire from ceiling. Connect
GREEN
wire from
fan to
BARE
/
GREEN
wire
from ceiling. Use wire connectors provided
when making connections.
* Wrap each wire connector separately with
electrical tape as an extra safety measure.
Turn spliced/taped wires upward and gently
push these wires and wire connectors into
outlet box.
7. Wiring - Wall Control
Remove existing wall switch. Remove wall
control back plate by removing 2 screws on
the wall control--one on the top and one on
the bottom. Secure wall control back plate to
wall or structure with screws from existing
wall switch.
Connect
BLACK
wire from wall control to
BLACK
(
AC TO FAN
)
wire from wall. Connect
BLACK
wire from
wall control to
BLACK
(
AC
IN
) wire from wall. Use wire connectors
provided when making connections.
* Wrap each wire connector separately with
electrical tape as an extra safety measure.
Turn spliced/taped wires upward and gently
push these wires and wire connectors into
back plate.
Re-attach wall control to back plate using the
2 screws that were previously removed.
wall