background image

Flood Light Small

Installation Instructions

LITELUME™ seeks to deliver the most advanced and efficient LED technology. Due to 
technology progression, specifications may change. We reserve the right to update product 
specifications without notice. Contact LITELUME™ for the most up-to-date data.

www.litelume.com
[email protected]
833.LED.LUME

Page 1/2

Rev Date: 08/17/2018

©Lite Lume Corporation 2018

 Warning

1. To avoid electric shock, disconnect power at source prior to installation.
2. The installation should be performed by qualified electricians or lighting technicians.
3. This product must be installed in accordance with the national electric code (NEC) and all applicable federal, state and local 

electric codes and safety standards.

4. Disconnect product and allow cooling prior to servicing.
5. Any alteration or modification of this product is expressly forbidden as it may cause serious personal injury, death, property 

damage and/or product malfunction.

6. To prevent product malfunction and/or electrical shock this product must be properly grounded.
7. Suitable for operation in ambient temperatures ranging from -40°c to 45°c.
8. This product must be installed in accordance with the applicable installation code by a person familiar with the construction and 

operation of the product and the hazards involved.

1/2” Knuckle Mount Installation

Silicone gasket

1/2 Screw bracket

1/2 Nut

Waterproof ring

Screw

Wire Connection

Black

White

Neutral

Green/Yellow Green

Ground

Live

1. Mount this fixture to any metal 1/2’’ NPS threaded mounting (supplied by others) , please mount the fixture prior to make wiring 
connection.
2. Route electrical leads through the mounting hole.
3. Seal knuckle threads with sealing compound (provided by others). Secure the mounting fitter to fixture with lock nut.
4. Make wire connection (see wiring diagram above).
5. Adjust aiming angle of the fixture by loosening the pivot screw. Use visual angle indicators to set desired angle, then tighten 
pivot screw. 

Trunnion Mount Installation

Screw

Trunnion

1. Fix trunnion on the wall by screws.
2. Wire Live and Neutral Cable respectively. Watch out for joint point and screw them well in case of electric leakage.
3. Adjust light by loosening screws to achieve different installation angle. 
4. Waterproof measurement are necessary when connecting to external power supply cord.

Troubleshooting

1. Check that the line voltage at the fixture is correct. Refer to wiring diagram above.
2. Is the fixture grounded properly?
3. Be sure the photocell, if used, is functioning properly.

Отзывы: