LiteGait 300MX Скачать руководство пользователя страница 21

 

21 

www.LiteGait.com 

1-800-332-9255 

Connect the Harness to your LiteGait® 

 

1.

 

Lock all four casters to make the device stationary and adjust the yoke to the correct position, giving the patient 

approximately 5 to 6 inches of head clearance. 

2.

 

Extend the overhead straps until they are long enough to reach the metal buckles on the harness. Attach the four 

buckles  that  hang  from  the  overhead  straps  to  the  appropriate  buckles  on  the  harness.  Pull  (shorten)  the  back 
straps until there is no slack. Leave a few inches of slack in the front straps. 

3.

 

Once the patient  is connected, unlock casters. With one  hand on LiteGait, press up button on hand switch to lift 

patient into a standing position. Roll LiteGait® forward slightly while lifting so patient ends up directly under the 
yoke  buckles.  If  desired,  have  patient  hold  handlebars  during  sit  to  stand.  If  necessary,  adjust  height  of  the 
handlebars to suit the patient. 

4.

 

Re-adjust overhead straps to maximize postural support as necessary. To tighten (shorten) strap, gently lift up on 

the connected section of the strap and pull down on the loose end of the strap simultaneously.  To lengthen strap, 
lift metal tab up and out and then pull down on strap. Repeat as necessary for all straps.  

5. The unit can now be used for over ground therapy or to assist the patient in stepping up onto the treadmill. 

If Lifting is not Necessary 

With higher level patients who don’t need assistance to achieve standing, the harness may be connected to the 
LiteGait® with the patient standing on the floor or over the treadmill.  
1.

 

Lock all four casters to make the device stationary and adjust the yoke to the correct position, giving the patient 

approximately 5 to 6 inches of head clearance. 

2.

 

Extend the overhead straps until they are long enough to reach the metal buckles on the harness. Attach the four 

buckles  that  hang  from  the  overhead  straps  to  the  appropriate  buckles  on  the  harness.  Adjust  all  straps  to 
maximize postural support as necessary. 

3.

 

If handlebars are desired, adjust height of the handlebars to suit the patient. 

4.

 

The  unit  can  now  be  used  for  over  ground  therapy  or  to  assist  the  patient  in  stepping  up  onto  the  treadmill  if 

necessary. 

Training with 

Lite

Gait®

 

Stepping up onto Treadmill

 

1.

 

Position LiteGait® unit at the end of the treadmill walking surface (if not already there) and 

lock  both  directional 

casters

.  

2.

 

Standing  beside  the  patient,  slowly  roll  the  unit  forward  toward  the  front  of  the  treadmill  while  simultaneously 

pressing the up button on the hand switch.   

3.

 

While continuing to press the up button, assist the patient with stepping up onto the treadmill as needed.  

4. Once the patient is standing on the treadmill, quickly re-tighten the overhead straps if necessary to increase the 

support provided by the unit, or use the lift mechanism to increase the overall support. In some cases it may be 
necessary to tighten all four overhead straps in order to decrease the distance between the patient’s head and the 
overhead support (to achieve the ideal 5 to 6 inches of head clearance). 

4.

 

Roll the unit to the front of the treadmill and 

lock the caster brakes

5.

 

Double check to see that the unit is locked into place and that the patient is in the center of the treadmill walking 

surface. 

6.

 

Adjust the handlebars to the appropriate height. 

CONTINUED ON PG 24

 

Содержание 300MX

Страница 1: ...Operator Service Manual LiteGait 300MX LiteGait is a Registered Trademark of Mobility Research Inc ...

Страница 2: ......

Страница 3: ...Number of Your Device Note Please keep your serial number in a safe and secure location The serial number must be pro vided when seeking service for your LiteGait device The serial number provides us access to techni cal information regarding your device ...

Страница 4: ......

Страница 5: ...e professional or caregiver Brakes should remain in the locked position at all times until transfer from one location to another is initiated Operate on smooth and level surfaces ONLY READ ALL INSTRUCTIONS BEFORE USING LiteGait WARNING MAXIMUM PATIENT WEIGHT LiteGait 300MX 300 lbs MAXIMUM UNIT HEIGHT 7 feet 5 inches ...

Страница 6: ......

Страница 7: ... to your individual situation Our website also offers valuable information Like all quality therapy equipment LiteGait requires regular inspections Enclosed is a check list for your convenience Please complete the checklist every 6 months to ensure the efficient safe and effective operation of the LiteGait unit If you should find a problem with a Lite Gait part please contact the Technical Support...

Страница 8: ......

Страница 9: ...SING Your LiteGait 14 I Raising and Lowering Yoke 14 II Charging LiteGait 14 III Adjusting Handle Bars 15 IV Base and Casters 16 III Harness Application 18 Training with LiteGait 21 Unit Care and Maintenance 23 Troubleshooting 26 Parts List 28 Appendix BiSym 30 Resource Directory 38 Limited Warranty Certificate 39 ...

Страница 10: ...xterior box in order to expose equipment 4 Examine contents Report any damage to equipment immediately to Mobility Research Technical Sup port 6 Remove cardboard harness and accessories box 7 Open cardboard harness and accessories box 8 Inspect contents of harness and accessories box for damage 9 Carefully cut all black plastic straps securing base to pallet 5 Loosen handle bar knobs and raise han...

Страница 11: ...s hand tighten bolts ensure one person holds actuator steady until secure Tighten bolts using 5 16 inch Allen wrench until snug do not to over tighten 19 Verify operation by moving actuator up down by pressing the arrows on the hand switch If hand switch fails to operate the actuator check connections at top of the actuator 20 Carefully remove all shrink wrap from handle bars yoke and base 21 Veri...

Страница 12: ...12 www LiteGait com 1 800 332 9255 SECTION LEFT INTENTIONALLY BLANK ...

Страница 13: ... lowers the yoke The actuator consists of a concentric ex panding and retracting square tower that houses the DC motors gearing and the screw mechanism It also provides the structural base to which the adjust able handlebars are attached CONTROL UNIT Junction box mounted in the base for the battery power handheld switch and contains electrical safety protection circuitry The battery pack connects ...

Страница 14: ...the appropriate 110 volt Step 3 Leave LiteGait on charger for 6 8 hours or overnight once per week The time it takes to recharge the battery pack depends upon the health of the battery pack and how low the battery pack was before charging began Step 4 After charging the LiteGait unplug the charger from the WALL OUTLET AND LiteGait Note Leaving a charger connected to the LiteGait while dis connecte...

Страница 15: ...the location of all cable that plug into the control box for the LiteGait During use the battery cable and hand switch cable should be connected When charging the charger cable should be plugged in and the LiteGait should not be used Note Ensure that all plugs are inserted completely and se curely III Adjusting Handle Bars Raising and Lowering the Handle Bar Loosen each knob in equal portions The ...

Страница 16: ...ctional Locking Casters with Treadmill Position LiteGait near the treadmill or where you wish the patient to begin walking Roll LiteGait towards the front of the treadmill until the casters line up parallel to the treadmill or parallel to the path the patient will follow a hallway for example Press the directional locks to lock swivel of casters LiteGait can now be easily rolled back and forth ove...

Страница 17: ...17 www LiteGait com 1 800 332 9255 Using Your LiteGait SECTION LEFT INTENTIONALLY BLANK ...

Страница 18: ...erior diameter for the patient 2 Adjust the groin strap buckles so there is symmetry in the straps equal strap length available on both ends of the padded groin piece and equal from side to side 3 Attach the groin piece to the back of the harness NOTE The side of the groin piece with the H outline stitching most padded will go against the patient s body Front Overhead Straps Groin Pieces Girth Adj...

Страница 19: ... weight evenly throughout harness wrap Attaching Groin Pieces 1 Route the groin piece between legs to front 2 Connect both buckles one on each side 3 Tighten the groin strap snugly so there is NO slack To tighten grab the groin strap or strap cover and i Pull out toward adductor surface of leg ii Pull up toward groin piece buckle iii Use other hand to pull down on excess strap on free end then rep...

Страница 20: ...ened completely using a two handed technique and getting rid of all slack to properly anchor the harness in place and properly transfer the support to the thighs Harness Application In Supine 1 Roll patient away from you 2 Attach groin piece and place harness on patient with half of the harness rolled and under patient Figure 1 3 Hold harness in place with lowest strap at greater trochanter 4 Roll...

Страница 21: ...k all four casters to make the device stationary and adjust the yoke to the correct position giving the patient approximately 5 to 6 inches of head clearance 2 Extend the overhead straps until they are long enough to reach the metal buckles on the harness Attach the four buckles that hang from the overhead straps to the appropriate buckles on the harness Adjust all straps to maximize postural supp...

Страница 22: ...balance training therapeutic exercise postural support for ADL etc Please refer to your booklet Protocols for Partial Weight Bearing Gait and Balance Therapy for more information or email our clinical support department at clinicalsupport litegait com Stepping up onto Treadmill Continued 7 To exit the unit reverse the process Keep directional casters locked until the LiteGait is at the end of the ...

Страница 23: ... CONTROL GUIDELINES Cleaning Agent FOLLOW FACILITY INFECTION CONTROL GUIDELINES Water Temperature WASH IN UP TO 176 F 80 C Drying Method Harnesses should be dried with LOW or NO HEAT TUMBLE DRY Special Cleaning WIPED WITH DISINFECTION WASH PER FACILITY INFECTION CONTROL PROCEDURES Water temperatures between 104 F and 176 F may cause wrinkling of the iHarness material Harness Storage The harness ha...

Страница 24: ...Rusted Bolts Discoloration Degradation Battery 24 30 Months Charger Hand Switch Harness Wrap 18 24 Months Groin Pieces 18 24 Months Overhead Straps Casters Knobs Pins Grips Covers Caps Buckles Base Actuator Replace As Needed Based on Condition Facility Name City State First Last Title Phone Fax Email Model Serial Number Please Send Copy of Completed Form Every 6 Months to Mobility Research Service...

Страница 25: ...e caster should not swivel and the wheel should not rotate When unlocked the casters should swivel and rotate freely Handle Bar Knobs Knobs should screw in and out with ease When tightened snug the handlebars should be secured into position Power System Test actuator to see if UP and DOWN Buttons make actuator raise and lower If actuator beeps when raising or lowering the battery has a low charge ...

Страница 26: ...en in service for 30 months or more Contact Technical Support for replacement battery information 6 Possible Cause Resolution Other Power System Issue Contact Technical Support for further troubleshooting instruction Symptom Battery Does Not Hold Charge 1 Possible Cause Resolution Low Battery Charge Charge the battery following the appropriate charging instructions until full charge 2 Possible Cau...

Страница 27: ...t rests below the rib cage Applying the harness and groin piece loosely will cause them to slide upward Symptom Frontal overhead straps are causing discomfort in the chest area of female patients 1 Possible Cause Resolution The distance between the overhead straps places load on breasts Use an extender to increase the front panel size and distance between the overhead straps possibly avoiding the ...

Страница 28: ...h GPS s Harness Wrap with 9 10 5 Groin Pieces 9 Groin Piece for HS HSIN GP9 10 5 Groin Piece for HS HSIN GP9 HSIN A910 XL iHarness with GP s 500 lb Units ONLY Harness Wrap with Short and Long Pairs of Groin Pieces HXIN ASL Junior iHarness Wrap with GP s Harness Wrap with 6 8 Groin Pieces 6 Groin Piece for HJ HJIN GP6 8 Groin Piece for HJ HJIN GP8 HJIN A68 Diaper Harness Diaper Harness with Metal B...

Страница 29: ...ly locked into the correct position on the actuator post HB30E C 2 Handle Covers Black 5 covers for the handles of the handlebars base box HB30E D 2 Adjustable Handles Handle is connected to the handlebars base box and can be positioned proximal or distal and locked into place with handle pin Does not include patient grip covers HB30E G 2 Patient Grip Covers Black 6 covers for the adjustable handl...

Страница 30: ...o set the max duration of data collection session press the icon Time countdown upon initiation of the monitor session A lower value conserves tablet battery and charge Display the values of support provided by the LiteGait in the selected weight units or a percentage of the patients body weight Toggle weight or percentage by pressing the blue circle icon on the display Weight Percent Patient weig...

Страница 31: ...sion time shown in seconds Press Stop to end session Set Goal is listed in bottom right corner Green bar indicates set goal is being met Fuchsia bar indicates set goal is not being met Bar increase and decreases with the change of the support from patient SET USER WEIGHT Set user s weight Slide scale up or down to adjust scale Weight defaults at 150 lbs If a weight goal is set adjusting the patien...

Страница 32: ...ement Left and Right readings are disabled As support increases the size of arrows increases Symmetric bar displays t h e d i f f e r e n c e between the left and right sides Toggle goal sounds On Off Limit Support Positive results being met will produce positive chimes noises Limit Weight Bearing Negative results being met will produce negative storm noises Appendix BiSym ...

Страница 33: ...blet WiFi or WiFi direct Saving the session will save a copy of the report and data file on the tablet under the BiSym folder Enter file name File name defaults to session date time Files can be emailed by setting up an email account on the tablet and connecting to local WiFi network Press to save report and data file Total body weight min max and average SECTION INTENTIONALLY LEFT BLANK Appendix ...

Страница 34: ...B charger NOTE BiSym display will require routine charging Monitor the display battery using the battery indicator in the top right hand corner of the display Connect charging cable as needed 4 Reconnect charging m i c r o U S B instrumentation cable to display Slide Holder Insert tablet 1 I f a p p l i c a b l e s e e instructions to install tablet holder to LiteGait 2 Insert edge of tablet into ...

Страница 35: ...t Bluetooth 4 Select BiSym Device 5 After selecting to Pair t h e d e v i c e s h o u l d display under Paired Devices 6 Return to desktop and select BiSym 7 Touch the menu at the t o p r i g h t s e l e c t configuration 9 Touch select device 8 Enter password mobility to open the configuration screen 10 Select the Bisym device 11 Select Apply ...

Страница 36: ...e Parts department at 1 800 332 9255 EXT 7104 FOR MOBILITY RESEARCH USE ONLY Press apply to save and exit Configuration is password protected The password to access the configuration screen is mobility Press OK to access configuration Side View box should be selected for use with the Integrated FreeDomeYoke Turn On Off Sound effects Enter calibration screen to Change units from lbs to kg Calibrate...

Страница 37: ...37 www LiteGait com 1 800 332 9255 SECTION LEFT INTENTIONALLY BLANK Appendix BiSym ...

Страница 38: ...arts Department Service LiteGait com Clinical Support ClinicalSupport LiteGait com Education Department Education LiteGait com Sales Department Sales LiteGait com POSTAL ADDRESS Mobility Research P O Box 3141 Tempe AZ 85280 2018 US LiteGait is a Registered Trademark of Mobility Research Inc PO Box 3141 Tempe AZ USA 85280 ...

Страница 39: ...THORIZED TO MAKE ANY MODIFICATION EXTENSION OR ADDITION TO THIS WARRANTY MOBILITY RESEARCH IS NOT RESPONSIBLE FOR DIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM ANY BREACH OF WARRANTY OR CONDITION OR UNDER ANY OTHER LEGAL THEORY INCLUDING BUT NOT LIMITED TO LOST PROFITS DOWNTIME GOODWILL OR DAMAGE TO EQUIPMENT AND PROPERTY Warranty excludes damage due to normal wear and tear tam...

Отзывы: