1. Introduction 

1-1 Feature 

 

Standard DMX control. When the DMX value higher than 75%, curtain motor start 

to rotate clockwise; when the DMX value lower than 25%, curtain motor start to 

rotate counterclockwise; When the DMX value is in the range of 25

%-

75

, the 

curtain motor stop rotating. 

 

2 dry contacts output control the curtain motor rotate clockwise and 

counterclockwise. 

 

Accept ECP control panel.   

 

Can save 6 scenes. 

 

1-2 Specification 

 

Power supply: AC 100-240V 50Hz-60Hz 

 

Protocol: DMX-512/RS-485 

 

Signal connector: 6P6C PHONE JACK(RJ11) *2, 4Pin green terminal 

 

Installation: track-mounted 

 

Dimension: 198 (W) x 90 (H) x 62 (D) mm 

 

Weight: 650g 

 

Содержание EDX-B02D

Страница 1: ...EDX B02D EUM B 0 User Manual EDX B02D 2 Channel Curtain Controller...

Страница 2: ...on 5 2 2 DMX Address Setting 5 2 3 Motor Control 6 2 4 Accept Refuse DMX Signal 6 2 5 ID No Setting 7 2 6 Zone Setting 7 2 6 1 Single Multi Zone Setting 7 2 6 2 Single Zone Setting 7 2 6 3 Multi Zone...

Страница 3: ...se When the DMX value is in the range of 25 75 the curtain motor stop rotating 2 dry contacts output control the curtain motor rotate clockwise and counterclockwise Accept ECP control panel Can save 6...

Страница 4: ...EDX B02D EUM B 3 1 3 Dimension 1 4 Panel Introduction 11 1 2 3 4 5 7 10 0 9 6 8...

Страница 5: ...n FCN function button direction button 6 Power indicator 4 5 8 Signal input DMX 512 RS485 7 Communication indicator 9 Counterclockwise shortcut button and indicator 10 clockwise shortcut button and in...

Страница 6: ...ys STEP 2 Press DMX to initial STEP 3 then enter the main screen Press FCN after STEP 2 can stop initialization 2 2 DMX Address Setting Standard DMX console can output 512 channels and EDX B02D can us...

Страница 7: ...r Control On the main page hold to start the motor rotate clockwise hold to start the motor rotate counterclockwise release or the motor will stop rotating 2 4 Accept Refuse DMX Signal STEP 1 On the m...

Страница 8: ...FCN to exit 2 6 Zone Setting Definition of zone The device must set the Zone No before using which consists of two parts one is the zone no and another is the start channel address 2 6 1 Single Multi...

Страница 9: ...cursor will blink STEP 2 Press or can modify channel STEP 3 Press or to shift to zone select state The cursor will blink STEP 4 Press or can choose channel zone Up to 99 Zones STEP 5 Press or to shif...

Страница 10: ...ene SC1 6 STEP 3 After setting press DMX to save press FCN to exit 2 9 Scene Duration Setting STEP 1 On the main page press FCN four times to enter Scene Duration Setting The cursor will blink STEP 2...

Страница 11: ...t UP DOWN In which UP motor rotates clockwise DOWN motor rotates counterclockwise STEP 5 Press or to shift to motor operation setting screen STEP 6 Press or to select motor rotate time 1 99s or any on...

Страница 12: ...s control c Labor costs incurred in diagnosis of defects installation reinstallation wiring rewiring repairing adjustment or reprogramming of a product or any other consequential expenses d Other Lite...