background image

ISO 9001 CERTIFIED

www.liteputer.com.tw

Lite-Puter

EDX-607E [EUM-A]

19

2-20

Enable/Disable Partition Function

STEP-1Long hold

FCN

for 3 seconds to enter function menu and then press

FCN

until the screen shows

.

STEP-2Press

to turn on partition function

press

to turn it off.

STEP-3Press

ENTER

to save and exit.

2-21

Checking Software Version

Long hold

FCN

for 3 seconds to enter function menu and then press

FCN

until

the screen shows

.

LED screen shows the software version as

.

2.22

Enable/Disable IR Remote Control

STEP-1Long hold

FCN

for 3 seconds to enter function menu and then press

FCN

till the screen displays

.

STEP-2Press

to turn on IR remote control( EDX-607 under the IR remote

control)or press

to turn off IR remote control

EDX-607 out of IR remote control

.

STEP-3After setting, press

ENTER

to save and exit.

2-23

Enable/Disable SC5/6 Overlap Scene Function

On usual, when user select a scene, the previous scene will be replaced. This

function is for overlap SC5 or SC6 to another scene. If you recall one of SC1-4 first,

then recall SC5 or SC6, the later one will overlap to the previous one, so user will see

two scenes at the same time. If there is any channel that is in both scenes, it will be

outputted at the higher dimming value.

C1

Curve

C2

Curve

C3

Curve

Содержание EDX-607

Страница 1: ...ISO 9001 CERTIFIED www liteputer com tw Lite Puter EDX 607E EUM A EDX 607 6 Channels Lighting Controller User Manual Lite Puter Enterprise Co Ltd www liteputer com tw sales liteputer com tw...

Страница 2: ...Clock Setting 13 2 9 Timer ON OFF 14 2 10 Dimming Switch Non dimming Mode Setting 14 2 11 Display System Temperature 15 2 12 Display Current Load 15 2 13 Set Timer 15 1 Add Record 15 2 Edit Record 16...

Страница 3: ...ghting scenes periodically and automatically 24hours Each channel can be set as dimming or non dimming Display system temperature and detect temperature automatically When the internal temperature is...

Страница 4: ...ISO 9001 CERTIFIED www liteputer com tw 2 Lite Puter EDX 607E EUM A 1 3 Wiring Diagram 1 4 Installation...

Страница 5: ...ISO 9001 CERTIFIED www liteputer com tw 3 Lite Puter EDX 607E EUM A...

Страница 6: ...ISO 9001 CERTIFIED www liteputer com tw 4 Lite Puter EDX 607E EUM A...

Страница 7: ...ISO 9001 CERTIFIED www liteputer com tw 5 Lite Puter EDX 607E EUM A 1 5 System Wiring Diagram...

Страница 8: ...w 6 Lite Puter EDX 607E EUM A 1 6 Panel introduction 1 Scene buttons 2 IR receiver 3 LED 4 Channel dimming value display or other function meaning 5 Function buttons 6 CH1 CH12 dimming value UP 7 CH1...

Страница 9: ...UP Set ID No FCN CH2_UP Set Zone No FCN CH3_UP Set DMX start channel address FCN CH4_UP Set scene FADER TIME FCN CH5_UP Modify system time FCN CH6_UP Timer on off FCN CH1_DOWN Channel dimming switch n...

Страница 10: ...system 2 3 DMX Start Channel Setting STEP 1Press FCN CH3_UP at the same time or long hold FCN for 3 seconds to enter function menu and then press FCN twice to select function the screen will display i...

Страница 11: ...to enter function menu and then press FCN once to select function The screen will display The two digits on the right side are blinking 2 Press once the two digits on the left side are blinking it wil...

Страница 12: ...to partition 3 and other channels to partition 1 default The steps are as follows 1 Enter The LED bars of channel 1 6 show all of them are in partition 1 2 Press S to check channel 7 12 the LED bar o...

Страница 13: ...01 CERTIFIED www liteputer com tw Lite Puter EDX 607E EUM A 11 4 Press CH1_UP to set channel 1 to partition 2 the LED bar shows that channel 1 is in partition 2 now 5 Press once to shift to partition...

Страница 14: ...l 10 to partition 3 8 Press ENTER to save and exit 2 6 ID_NO Setting STEP 1Long hold FCN for 3 seconds or press FCN CH1_UP at the same time the screen will display its ID number Each EDX Series device...

Страница 15: ...d to 5 seconds The steps are as follows 1 Long hold FCN for 3 seconds to enter function menu and then press FCN 3 times to select the function or press FCN CH4_UP at the same time the screen will disp...

Страница 16: ...necessary users can set the channel to switch mode and control it with either 100 on or totally off If any channel is set in switching mode it will be turned on to 100 immediately when the input is ov...

Страница 17: ...e to 0 smoothly till the temperature below 55 C when it over 65 C EDX 607 will stop output immediately 2 12 Display Current Load Long hold FCN for 3 seconds to enter function menu and then press FCN 9...

Страница 18: ...number and press for 3 seconds to delete the record The screen will show as below it means the record was deleted 2 14 Scene Setting Press CH1 CH6 UP DOWN to adjust 12 channels the dimming value Ther...

Страница 19: ...ans storing the current setting to scene 2 2 15 Scene Recall Press scene buttons 1 6 to recall the scene 1 to scene 6 correspondingly The LED nearby the scene button will be lightened Press SHIFT 1 6...

Страница 20: ...annels STEP 1 Long hold FCN for 3 seconds to enter function menu and then press FCN 10 times to select the function or press FCN CH5_DOWN at the same time the screen will display the status of LED scr...

Страница 21: ...for 3 seconds to enter function menu and then press FCN till the screen displays STEP 2Press to turn on IR remote control EDX 607 under the IR remote control or press to turn off IR remote control ED...

Страница 22: ...6 CH1 100 CH2 100 CH3 100 When users recall SC1 first and then recall SC5 CH1 will output 80 CH2 will output 80 and CH3 will output 100 When users recall SC1 first then SC5 and last SC6 CH1 will outpu...

Страница 23: ...refer to Dimmer Switch Mode Setting in this manual Current Loading Precaution To prolong the life of the device we suggest you refer to the following instruction 1 Keep adequate ventilation If the mac...

Страница 24: ...ials and any other logical reasons in good repair for free within a year since the distributing date 3 We do not offer door visiting service If the trouble appears in Lite Puter s products please deli...

Страница 25: ...teputer com tw E mail sales liteputer com tw Shanghai Factory Lite Puter Technology Shanghai Co Ltd Address Building B5 No 298 Lane 3509 Hongmei S Road Shanghai China Zip Code 201108 Tel 86 21 5440821...

Отзывы: