LiquoSystems iFerm Nano Tank Скачать руководство пользователя страница 30

30

iFerm Nano Tank

Appendix

8.5 

Customer service

LiquoSystems is one of the few brand suppliers in the 

field of cellar technology for professional tank cooling 

and temperature control. We supply refrigerators, heat 

exchangers, temperature controllers and accessories, 

through to turnkey installation on your premises. 
If you have any questions about our products or about 

how to extend and optimise your system, please contact us 

directly:

LiquoSystems GmbH

 

Wilhelmstraße 45

74366 Kirchheim / Neckar, Germany

Tel.: +49 7143 891050 | Fax: +49 7143 92868

[email protected]

www.liquosystems.de

 

You’ll always be on the safe side with our factory customer 

service and repair service:

Technical assistance

Hours of business:

Mon. – Thu.: 09:00 am – 16:30 pm

Friday:

09:00 am – 13:00 pm

E-mail:

[email protected]

Phone:

+49 7143 891050

Hotline

10

th

 September to 10

th

 November

Mon. – Fri.:

08:00 am – 20:00 pm

Sat. + Sun.:

09:00 am – 18:00 pm

Содержание iFerm Nano Tank

Страница 1: ...2017 07 LiquoSystems GmbH 74366 Kirchheim Neckar Germany iFerm Nano Tank Operating instructions EN EN EN EN EN EN EN EN...

Страница 2: ...n terms of content in translated versions the information in the German version takes precedence If you come across any discrepancies please contact our customer service see 8 5 Customer service on pa...

Страница 3: ...Installation 16 4 1 Positioning the temperature controller 16 4 1 1 Installing the thermowell 16 4 1 2 Installing the temperature controller 17 4 2 Attaching the connecting cable 18 5 Operation 20 5...

Страница 4: ...4 7 Maintenance and care 26 8 Appendix 27 8 1 Technical data 27 8 2 Troubleshooting 28 8 3 Disposal 29 8 4 Declaration of conformity 29 8 5 Customer service 30 iFerm Nano Tank...

Страница 5: ...ation processes Temperature control applications for processes such as filtration bottling tartrate stabilisation room temperature control and stock cooling are still deemed to be proper Use for other...

Страница 6: ...tion of the iFerm Nano Tank Users must be at least 16 years of age They must have read and understood the operating instructions and must be able to follow all notices and instructions The operating i...

Страница 7: ...tices y y Read the operating instructions carefully and obey all safety notices Material damage resulting from ignoring the safety notices is not covered by any warranty y y Whenever you use iFerm Nan...

Страница 8: ...any aggressive scouring cleaning agents or cleaning agents containing solvents y y Do not perform any repairs on iFerm Nano Tank Follow the instructions in the chapter 7 Maintenance and care on page 2...

Страница 9: ...of the cooling pulses varies depending on the difference between the actual value and the target value In the event of major deviations the pulse pause ratio can be regulated in such a way that the v...

Страница 10: ...in a thermowell on the tank for installation y y Connecting cable with loose strands for connecting to the power supply data bus and valve by means of an optionally available iFerm Nano Box terminal b...

Страница 11: ...m Nano Box terminal box and connected as required see 4 2 Attaching the connecting cable on page 18 2 Type plate underside of controller housing 3 Display with display buttons see 3 3 Display on page...

Страница 12: ...rating state see 3 3 2 Status messages on page 14 3 PV area process value white characters Shows the measured actual temperature Shows the name of the current menu 4 SV area set value green characters...

Страница 13: ...e by 0 1 K in each case keep the button pressed for fast forward Reduce the value in the SV area or scroll back by one adjustment option Increase the target temperature by 0 1 K in each case keep the...

Страница 14: ...is activated Communication via the data bus is possible s err Error message in the PV display area sensor error The sensor shows incorrect behaviour see 8 2 Troubleshooting on page 28 When there is ce...

Страница 15: ...the data bus and the valves being controlled In conjunction with iFerm Nano Terminal you can also control the valve of a heating system in addition to the cooling valve iFerm Nano Terminal control uni...

Страница 16: ...Tank is placed 4 1 1 Installing the thermowell You can retrofit the thermowell if one is not already installed on the tank The optionally available versions can be screwed or welded onto the tank wall...

Страница 17: ...ong and 7 mm in diameter The thermowell used must fulfil the following criteria for a secure fit on the tank and to obtain the correct measurement results y y The probe rod of iFerm Nano Tank can be f...

Страница 18: ...onnected to a power supply see 5 1 Commissioning on page 20 Therefore do not switch on the power supply until connection and installation have been completed First plan the laying route for the connec...

Страница 19: ...lows Wire colour Assignment White 24 V AC 50 60 Hz power supply Brown 0 V AC 50 60 Hz power supply Green Switching contact cooling valve 24 V AC 50 60 Hz Yellow Modbus RS485 A Grey Modbus RS485 B Pink...

Страница 20: ...you start a process Switch on the power supply for the system in which iFerm Nano Tank is installed The display switches itself on and shows the actual and target temperatures The connected valve move...

Страница 21: ...tion that you must perform during operation of iFerm Nano Tank Check the setting at regular intervals Lower or increase the target temperature SV area by 0 1 degrees with each press of the button Or A...

Страница 22: ...Tank in display mode only you can deactivate Cooling mode Set a high value for the target temperature that the actual temperature of the process cannot attain e g 50 C This means that the valve const...

Страница 23: ...ect the parameter icpt initial setting communications protect The SV area shows the current setting The following values are defined for the button lock 0 The button lock is not activated 2 The button...

Страница 24: ...deactivate the button lock see 6 1 Activating and deactivating the button lock on page 23 Make the desired changes and then reactivate the button lock 6 2 1 Changing the appliance address Only necess...

Страница 25: ...an also be used in portable single operation if the power is supplied via the connecting cable with bus cable For this simply deactivate the communication connection to the central control unit 1x Cal...

Страница 26: ...efore have the inspections carried out regularly every 2 years Do not perform any repairs on iFerm Nano Tank If in doubt contact customer service see 8 5 Customer service on page 30 iFerm Nano Tank is...

Страница 27: ...m threshold 1 5 K Valve opening time Min 180 seconds Power supply 24 V AC 50 60 Hz Power consumption Max 5 W Protection class IP65 Length connecting cable approx 5 m Size H x W x D approx 120 x 100 x...

Страница 28: ...tton carefully see 7 Maintenance and care on page 26 Button faulty no contact Contact customer service The displayed actual temperature is imprecise or there is an error s err sensor error Temperature...

Страница 29: ...isposal regulations that apply in your region 8 4 Declaration of conformity iFerm Nano Tank Manufacturer LiquoSystems GmbH Wilhelmstra e 45 74366 Kirchheim Neckar Germany Declaration We hereby declare...

Страница 30: ...ducts or about how to extend and optimise your system please contact us directly LiquoSystems GmbH Wilhelmstra e 45 74366 Kirchheim Neckar Germany Tel 49 7143 891050 Fax 49 7143 92868 info liquosystem...

Страница 31: ...31 2017 07 Subject to change EN EN EN EN EN EN EN EN...

Страница 32: ...45 74366 Kirchheim Neckar Germany Tel 49 7143 891050 Fax 49 7143 92868 info liquosystems de www liquosystems de 2017 07 iFerm Nano Tank Solo Terminal Box Top Switch Tank iFerm Nano EVERYTHING FOR TAN...

Отзывы: