Liquiflo
Installation, Operation & Maintenance Manual
Poly-Guard
®
Series MAG-DRIVE Gear Pumps
Models P1 thru P9, Close-Coupled
24
Models P1-P4, shown
Close-Coupled to Motor
Models P5-P9, shown
Close-Coupled to Motor
5.4.3
Motor-to-Pedestal Assembly
23
Install the motor (with outer magnet) to the
pedestal (
25
) and bolt in place using four
bolts (
29
).
NOTE:
The C-faces of the motor and pedestal should
mate freely and mount flush. Refer to
Appendix 1
for the torque specifications of the fasteners.
5.4.4
Cartridge Installation
24
Carefully install the
pump cartridge
to the pedestal (
25
) using four sets of bolts (
26
), nuts (
27
) and lock
washers (
28
).
NOTE:
Hold the pump cartridge firmly as shown above and then slowly move the containment can inside the outer magnet. The faces
of the pedestal and cartridge will mate freely and mount flush. Refer to
Appendix 1
for the torque specifications of the fasteners.
END OF ASSEMBLY PROCEDURE
Caution!
Do not place hands or fingers between the Pedestal and Cartridge. The
Outer and Inner Magnets will suddenly pull together with significant force.
SLOWLY