Liquiflo
Installation, Operation & Maintenance Manual
Poly-Guard
®
Series MAG-DRIVE Gear Pumps
Models P1 thru P9, Close-Coupled
13
Pump Port
5.3
PUMP DISASSEMBLY
Follow the procedure below and refer to the Exploded View Drawing on page 27.
5.3.1
Cartridge Removal
1
Remove the four sets of bolts (
26
), nuts (
27
)
and lockwashers (
28
) that secure the
front housing (
15
) to the pedestal (
25
).
2
Remove the
pump cartridge
from the pedestal
by pulling it straight out.
NOTE:
Force will have to be applied to overcome
the magnetic attraction between the outer and
inner magnets.)
3
Drain the liquid inside the containment can (
20
)
thru one of the ports of the cartridge.
5.3.2
Cartridge Disassembly
4
Remove the six containment can
screws (
21
); then separate the
containment can (
20
) from the
front housing (
15
).
Caution!
Do not place hands or fingers between
the Cartridge and Pedestal.
Caution!
Some trace fluid may remain in the pump
and containment can even after draining.