Always make sure that the
slideout room path is clear of
people and objects before
and during operation of the
slideout room
Always keep away from the
slide rails when the room is
being operated. The gear
assembly may pinch or catch
on loose clothing causing
personal injury.
M²-Sync Room Slideout System
Page 2
Two different versions of touch pads are used on this system (see figure 1). Unless
otherwise noted, all operation of the control is the same regardless of which touch
pad comes equipped with your coach.
Touch Pad “A” has two LEDs. Fault code is indicated in Red and room/lock
movement is indicated in Green.
Touch pad “B” has four LEDs. Fault codes and low voltages are indicated in Red and
room/lock movement in Green. With this touch pad if the Park Brake LED is flashing,
you need to engage the park brake to operate your slideout system and if the Low
Voltage LED is flashing, you will need to start and run the coach or generator to
operate the slideout system. Let the engine/generator run for a few minutes to allow
the batteries time to fully charge before operating.
Note
:
▪ The system will not work until stops are properly set or faults are cleared.
▪ The GREEN LED indicates system operation. (Figure 1)
◦ A solid GREEN LED indicates room movement
◦ A flashing GREEN LED indicates room lock movement, if room is equipped
with room locks.
▪ The RED LEDs indicates a fault or problem with the system (Figure 1). Refer to the
Fault Diagnostics in this manual for additional information.
▪ Prior to moving the slideout room, make sure the engine or generator is running to
ensure ample voltage to the motors and the parking brake is set.
EXTENDING THE ROOM
1. The engine or generator must be running or apply shore power.
2. Set the park brak and level the unit.
3. Remove transit bars (if so equipped).
4. Turn ‘ON’ the on/off switch or key (if so equipped).
5. Press and hold the OUT button (Figure 1). If equipped with electronic room locks,
the room locks will retract prior to room movement. Reference the GREEN LED
indications above to determine component movement.
6. Release the button when room is fully extended and stops moving.
7. Turn 'OFF' the on/off switch or key (if so equipped).
RETRACTING THE ROOM
1. Follow steps 1-4 above and then continue below with step 5.
5. Press and hold the IN button (Figure 1) If equipped with electronic room locks, the
room locks will automatically extend when the room is fully retracted. Reference
the GREEN LED indications above to determine component movement.
6. Release the button when room is fully retracted or when the room locks are fully
engaged and stop moving.
7. Turn 'OFF' the on/off switch or key (if so equipped).
8. Install the transit bars (if so equipped).
Operation Mode
WARNING
!
Figure 1
TOUCH PAD “A”
TOUCH PAD “B”
LED
LED
GREEN
RED
g g
7. Turn 'O
O
F
F
F
8. Install th
LED
LED
OUT
BUTTON
IN
BUTTON
IN BUTTON
OUT BUTTON
GREEN LED
RED LED
CCD-0002533