Zero Point Calibration
The "Zero Point" is the programmed point to which the 5th Wheel will return whenever the auto-level
feature is used. The Zero Point is preset at the factory and should never have to be reset. However, if
necessary, Zero Point can be reset.
Note:
The Zero Point must be programmed prior to using the auto-level feature to ensure the proper
operation of the system. Prior to starting the Zero Point Calibration procedure, check all connections
on the controller, valve coils, landing gear, leveling jacks and touchpad.
1.
Manually run all leveling jacks and landing gear to level the 5th Wheel.
A. This is best achieved by placing a level in the center of the 5th Wheel and leveling it both front-to-
back and then side-to-side.
B. See Basic Jack Operation section for instructions on how to manually operate the system.
2.
After the 5th Wheel has been leveled, turn off the touchpad.
3.
With the touchpad off, press and release the FRONT button (Fig. 1G) ten times and then press and
release the REAR button (Fig. 1J) ten times.
4.
The touchpad will flash and beep, then the LCD screen will read "ZERO POINT CALIBRATION ENTER to
set, Power to Exit” (Fig. 7).
Fig. 7
Fig. 8
Fig. 9
5.
To set the current position as the zero point, press the ENTER button (Fig 1C).
A. the LCD screen will read “Zero point stability check” (Fig. 8).
6.
LCD display will read “Zero point set successfully” once process is complete (Fig. 9).
7.
The system will set this point as its level state and the touch pad will turn off.