TROUBLESHOOTING

The 

Lippert Electric Slideout System

 is only one of four interrelated

slideout room system components. These four components are: chassis,
room, coach, and 

Lippert Electric Slideout System

. Each one needs to

function correctly with the others or misalignment problems will occur.

Every travel trailer has its own personality and what may work to fix one
trailer may not work on another even if the symptoms appear to be the
same.

When something restricts room travel, system performance will be
unpredictable. It is very important that slide tubes be free of
contamination and allowed to travel full distance (Stroke). Ice or mud
buildup during travel is an example of some types of contamination that
can occur.

When you begin to troubleshoot the system, make sure the battery is
fully charged, there are no visible signs of external damage to the
actuator or motor and that the motor is wired correctly and all
connections are secure.

You can adjust the room extension with the jam nuts on the end of the
actuator threaded rod (see page 11).

During troubleshooting, remember that if you change something, that
change may affect something else. Be sure any changes you make will
not create a new problem.

You can obtain additional information on the

Lippert Electric Slideout System

by calling 866-524-7821.

16

Содержание ELECTRIC SLIDEOUT SYSTEM

Страница 1: ...ELECTRIC SLIDEOUT SYSTEM OPERATION AND SERVICE MANUAL revB...

Страница 2: ...Warning Extending Slideout Room Retracting Slideout Room Manual Operation SERVICE Adjustment Instructions System Components Syncronizing System Replacing Actuator Troubleshooting Wiring Diagram Order...

Страница 3: ...uld be clear of obstructions that may cause damage when the slideout room is actuated 2 Be sure all persons are clear of the coach prior to the slideout room actuation 3 Keep hands and other body part...

Страница 4: ...ttery must be maintained at full capacity Other than good battery maintenance check the terminals and other connections at the battery the control switch and the electric actuator motor for corrosion...

Страница 5: ...uipped 4 Press and hold the IN OUT switch Fig 1B in the OUT position until the room is fully extended and stops moving 5 Release the switch which will lock the room into position Note If the slideout...

Страница 6: ...t to note that you DO NOT need to attempt to disengage the motor as the actuator is manual ready Just hook up and crank Use EXTREME CAUTION when extending and or retracting room using the manual overr...

Страница 7: ...MANUAL OPERATION THROUGH FRAME Through Frame Crank Extension w pin Crank Handle Fig 2 Fig 3 7...

Страница 8: ...MANUAL OPERATION IN FRAME Motor Hex Head Crank Extension Fig 4 Fig 5 Ratchet 8...

Страница 9: ...nd of each guide tube 2 Room is ready to be positioned horizontally by pushing on the outside sidewall or by using a prying devise inserted into the opening between the room and coach Note Use caution...

Страница 10: ...MECHANICAL ROOM ADJUSTMENT Fig 6 Bolt B Jam Nut Bolt A Bolt A Fig 7 10...

Страница 11: ...out or in and then tighten down the nut this will change the location of your seal going to the in position Adjusting room so it seals in the OUT position 1 Locate actuator coming through the frame 2...

Страница 12: ...12...

Страница 13: ...13...

Страница 14: ...ronizing bracket mounted on the passive slide tube The passive slide tube is the one that is not powered The active slide tube is the one that has the cylinder attached If one side of the room fails t...

Страница 15: ...urements A and B Fig B 4 Remove all jam nuts 3 total and stop can from threaded shaft on actuator Fig B 5 Take note of mounting bolt locations and remove mounting bolts Fig C 6 After everything is dis...

Страница 16: ...es be free of contamination and allowed to travel full distance Stroke Ice or mud buildup during travel is an example of some types of contamination that can occur When you begin to troubleshoot the s...

Страница 17: ...s Be sure that drive bracket they are properly tightened and adjusted Bad motor or gear housing Replace motor POWERUNIT RUNS BUT ROOM MOVES SLOWLY Low battery poor ground extremely Charge battery and...

Страница 18: ...tep 2 If YES at the motor check the incoming leads to 12V DC if necessary disconnect leads at wire splices Does meter indicate 12V DC If YES Motor needs to be replaced The motor is not field serviceab...

Страница 19: ...OR GREEN MOTOR 30A AUTO RESET BREAKER LOCATE WITHIN 18 OF BATTERY SWITCH BATTERY WHITE BATTERY BLACK BATTERY WHITE OUT RED MOTOR BLACK BATTERY BATTERY CAUTION HIGH VOLTAGE IN Fig 10 WIRING DIAGRAM AUT...