Outdoor Reset Control

This model also has Outdoor Reset control. An outdoor temperature sensor is used to monitor
the outside temperature. The electronic controls then regulate the water temperature based on
both the aquastat setting and the outside temperature to fine tune the boilers heat output. As
the temperature outside increases, the boiler control will decrease the target water temperature
set  on   the  aquastat.   By   modulating   the  boilers   heat  output   based   on   both  the   indoor   and
outdoor temperature, your CEBR model provides you with the ultimate in indoor comfort.

The graph below is an example with the aquastat set to 35º C. During colder weather, below -
20º C, the boiler will maintain the heat output at the aquastat setting, but as the temperature
increases outdoors, the heat output of the boiler will be decreased. For example when it is -10º
C   outside   the   water   temperature   will   be   32º   C,   and   when   it   is   5º   C   outside   the   water
temperature will be 27º C.

Target Water Temperature Example ( Temperature in  degrees C)

4

Содержание CEBR Series

Страница 1: ...an appropriate antifreeze Do not use any other liquids especially methanol automotive antifreeze or any kind of oil Do not exceed 50 antifreeze LION BOILERS CEBR Series Boiler Installation Manual CEB...

Страница 2: ...2...

Страница 3: ...le phase power to terminals L1 and L2 and connection of a neutral conductor to the N terminal see Fig 4 Three phase models require connection of three phase power of the correct voltage to the L1 L2 a...

Страница 4: ...he aquastat By modulating the boilers heat output based on both the indoor and outdoor temperature your CEBR model provides you with the ultimate in indoor comfort The graph below is an example with t...

Страница 5: ...8 11 11 25 208 3 31 2 40 32 CEBR 208 15 14 7 208 3 40 8 60 48 CEBR 208 22 22 5 208 3 62 5 100 80 CEBR 208 30 29 4 208 3 81 6 125 100 CEBR 600 9 9 600 3 8 7 15 12 CEBR 600 15 14 7 600 3 14 1 20 16 CEBR...

Страница 6: ...g system Pressure will decrease at a rate of 0 433 psi per foot above the fill point An expansion tank must be included to allow for approximately 4 expansion of the water in the entire heating system...

Страница 7: ...r the boiler 3 Though the unit is suitable for floor or wall mount only faces indicated as Zero Clearance may be mounted against combustible surfaces 4 Units must be mounted straight as shown in Fig 2...

Страница 8: ...block lower right terminal block see Fig 4 and Fig 5 The pump starts when the thermostat terminals on the control board are closed and stops when these terminals are opened If desired the pump may be...

Страница 9: ...on pump and not the boiler the anticipator should be set to match the current draw of the zone valve being used Temperature Control Setting The boiler has a temperature control knob know as an aquasta...

Страница 10: ...and thoroughly purged of air The automatic air vent is to assist in removing air from the top of the tank to prevent elements from burning out It alone is not sufficient in removing air from the entir...

Страница 11: ...cipator setting Check pump circulation Boiler operates continuously Check anticipator setting Boiler noisy Oversized pump Flow rate too high Flow rate too low Pump location incorrect Boiler not heatin...

Страница 12: ...that Boiler The obligation of the Manufacturer to repair replace or refund the purchase price exists provided the defective part or complete unit is returned to the Manufacturer ANY AND ALL TRANSPORT...

Страница 13: ...ITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED AND EXCLUDED FROM THIS LIMITED WARRANTY THE MANUFACTURER S LIABILITY ON ANY CLAIM OF ANY KIND INCLUDING NEGLIGENCE WITH RESPECT TO THE GOODS OR SE...

Страница 14: ...14...

Страница 15: ...15...

Страница 16: ...16...

Страница 17: ...17...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...Check the fuse on models equipped with a fuse a Remove the fuse located inside the boiler Check it for continuity Replace with a new fuse of the correct type if necessary b Otherwise replace the exist...

Страница 21: ...e sure the boiler and the heating system are completely full of water a Unplug the low water cut off from the control board Temporarily no more than one second place a jumper wire across the two pins...

Отзывы: