1
Description
The TT Series transceiver is designed for
reliable bi-directional, long-range remote
control applications. It consists of a highly
optimized Frequency Hopping Spread
Spectrum (FHSS) RF transceiver and
integrated remote control transcoder. The
FHSS system allows higher power and,
therefore, longer range than narrowband radios. The TT Series transceiver
has obtained modular approval for the United States and Canada.
Eight status lines can be set up in any combination of inputs and outputs
for the transfer of button or contact states. A selectable acknowledgement
indicates that the transmission was successfully received. Operating in
the 902 to 928MHz frequency band, the module is capable of generating
+12.5dBm and achieves a typical sensitivity of -113dBm.
Primary settings are hardware-selectable, which eliminates the need for an
external microcontroller or other digital interface. For advanced features,
optional software configuration is provided by a UART interface; however,
no programming is required for basic operation.
Housed in a compact reflow-compatible SMD package, the transceiver
requires no external RF components except an antenna, which greatly
simplifies integration and lowers assembly costs.
Features
•
FCC and Canada pre-certified
•
Long range (1 mile line of sight)
•
Low power consumption (19mA
RX, 35mA TX @ +12.5dBm)
•
No programming required
•
8 status lines
•
Bi-directional remote control
•
No external RF components
required
•
Selectable acknowledgements
•
No production tuning required
•
2
32
possible addresses
•
Serial interface for optional
software operation
TT Series
Remote Control Transceiver
Data Guide
Figure 1: Package Dimensions
Revised 3/7/13
0.131"
0.630"
1.150"
11
Model: TRM-900-TT
Model: TRM-900-TT
Lot FX9nnT
Lot FX9nnT
FCC ID: OJMTRM900TTA
FCC ID: OJMTRM900TTA
IC: 5840A-TRM900TTA
IC: 5840A-TRM900TTA
A large-print version of this document is available at
www.linxtechnologies.com.
31
Product Labeling
31
FCC RF Exposure Statement
32
Typical Applications
34
Power Supply Requirements
34
Antenna Considerations
35
Helpful Application Notes from Linx
36
Interference Considerations
37
Pad Layout
37
Board Layout Guidelines
39
Microstrip Details
40
Production Guidelines
40
Hand Assembly
40
Automated Assembly
42
General Antenna Rules
44
Common Antenna Styles
46
Regulatory Considerations
Warning:
This product incorporates numerous static-sensitive
components. Always wear an ESD wrist strap and observe proper ESD
handling procedures when working with this device. Failure to observe
this precaution may result in module damage or failure.
Содержание MDEV-900-TT
Страница 1: ...TT Series Remote Control Transceiver Data Guide...