15
Example:
5.2Button Message
IOT-CPANEL
reports battery level according to reportinginterval (1080 mins by default) and
button message when buttonis pressed.
Example:
Note: if you press one button more than 6 times in a row, the 7
th
and follow-upmessages will
delay delivery.
09 (Hardware Version)
01 40 =>V1.4
0a (Software Version)
01 14 =>V1.14
0b (Power On)
Device is on
16 (Device SN)
16 digits
ff0bff ff0101 ff166592b32851010013ff090100 ff0a0102
Channel
Type
Value
Channel
Type
Value
ff
0b
(Power On)
ff (Reserved)
ff
01
(Protocol Version)
01 (V1)
Channel
Type
Value
Channel
Type
Value
ff
16(Device
SN)
6592b328510
10013
ff
09
(Hardware version)
0100
(V1.0)
Channel
Type
Value
ff
0a
(Software
version)
0102
(V1.2)
Channel
Type
Description
01
75(Battery Level)
UINT8, Unit: %
ff
34(Button Message)
Byte 1: Button Number
Byte 2-3:Button LoRa D2DCommand,
the command is 01-06by default.
01 75 64
Channel
Type
Value
01
75 (Battery)
64 =>100%
ff 34 01 18 00
Channel
Type
Value
ff
34(Button
Message)
01 =>Button 1
18 00=>Thisbutton LoRa D2D
command is 0018