Input impedance:

Single ended

7K8ohms

Balanced

7K8ohms

Input level for clipping:

Balanced

2v rms 

Unalanced

4v rms 

Single ended

1.67 Vrms

Signal sensing threshold

>150uV

Output connectors:

Standard

Neutrik

Optional

Binding posts

Output power

230W rms into 4ohms

100W rms into 8ohms

Load tolerance

Unconditionally stable into all loudspeaker loads

Harmonic distortion

>0.02%

Frequency response

7Hz to 35kHZ (-3dB)

Peak output voltage

46V

Options and accessories:

• Wall mount system     • Active crossover system    •  Binding post output terminals

21

General safety instructions

1.

Read instructions. Read the safety and operating instructions before operating the appliance.

2.

Retain instructions. Retain the safety and operating instructions for future reference.

3.

Heed warnings. Observe all warnings on the appliance and in the operating instructions.

4.

Follow instructions. Follow all operating and use instructions.

5.

Water and moisture . Do not use the appliance near water, for example near a bathtub, washbowl, kitchen sink, laundry tub, in a 

wet basement, or near a swimming pool and the like.

6.

Carts and stands. Use only with a cart or stand that is recommended by the manufacturer

6a.

An appliance and cart combination should be used with care. Quick stops, excessive force, and uneven surfaces may cause the 

appliance and cart combination to overturn.

7.

Wall or ceiling mounting. Mount to a wall or ceiling only as recommended by the manufacturer.

8.

Ventilation. Site the appliance so that its location or position does not interfere with its proper ventilation. For example, the 

appliance should not be situated on a bed, sofa rug, or similar surface that may block the ventilation openings, or placed in a 

built-in installation such as a bookcase or cabinet that may impede the flow of air though the ventilation openings.

9.

Heat. Site the appliance away from heat sources such as radiators, heaters, stoves, or other appliances (including amplifiers) that 

produce heat.

10.

Power sources. Connect the appliances to a power supply only of the type described in the operating instructions or marked on 

the appliance.

11.

Grounding or polarisation. Do not defeat the safety purpose of the polarised or grounding type plug. A polarised  plug has two 

blades with one wider than the other. A grounding type plugs has two blades and a third grounding prong. The wide blade or the

third prong is provided for your safety. When the provided plug does not fit into your outlet, consult an electrician for 

replacement of the obsolete outlet.

12.

Power card protection. Route power cords so that they are not likely to be walked on or pinched by items placed upon or against 

them, paying particular attention to cords at plugs, power sockets, and at the point where they exit from the appliance.

13.

Protective attachment plug. As a safety feature the product is equipped with an attachment plug containing overload protection.

See the instruction manual about resetting or replacing the plug. Should the plug need replacing, ensure that a replacement is 

used which has the same overload protection as the original.

14.

Cleaning. The product should be cleaned only as recommended by the manufacturer.

15.

Power lines. An outdoor antenna should be located away from power lines.

16.

Outdoor antenna grounding. If an outdoor antenna is connected to the tuner/receiver, ensure that the antenna system is 

grounded to provide some protection against voltage surges and static build up. In the USA see article 810 of the National 

Electrical Code ANSI/NFPA 70 concerning installation requirements.

17.

Unplug this apparatus during lightning storms or when unused for long periods of time.

18.

Objects and liquid entry. Take care not to let objects or liquids fall into the product.

19.

Damage requiring service. The product should be serviced by qualified personnel if:

a)

The power cord or plug has been damaged.

b)

Objects or liquid have fallen into the product.

c)

The product has been exposed to rain.

d)

The product does not appear to operate normally or exhibits a marked change in operation.

e)

The product has been dropped or the enclosure damaged.

20.

Servicing. Don’t attempt to service the product beyond that described in the operating instructions. All other servicing 

should be referred to qualified service personnel.

ii

Содержание Twin Klimax

Страница 1: ...L i n n Tw i n K l i m a x D u a l S p e a k e r Powe r A m p l i f i e r...

Страница 2: ...with same type and rating Attention Utiliser un fusible de rechange de m me type Disconnect supply cord before changing fuse Attention Debrancher avant de remplacer le fusible Warning To reduce the ri...

Страница 3: ...a third grounding prong The wide blade or the third prong is provided for your safety When the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outle...

Страница 4: ...mains plug need replacing and you are competent to do this proceed as follows If you are in doubt contact your Linn retailer or a competent electrician a Disconnect the plug from the mains supply b C...

Страница 5: ...1994 Absorbed emissions EN60555 2 1987 Harmonics EN60555 3 1987 Voltage fluctuations EN55020 1987 Immunity FCC Notice Note This equipment has been tested and found to comply with the limits for a Clas...

Страница 6: ...mission of the publisher Printed in the United Kingdom Klimax is a registered trademark of Linn Products Limited British Registered Design Application Number 2080160 British Patent Application Number...

Страница 7: ...mode 5 So what s the problem 6 Some assorted facts 7 Inside the Klimax 8 The audio circuitry 9 Output current and protection 11 4 Installation 13 Heat 13 Mains supply 15 Signal sensing 17 Inputs and O...

Страница 8: ...uses the latest technology and exemplifies our constant endeavour to make ever better sounding products We are confident that the compact elegant design and the exceptional accurate performance of the...

Страница 9: ...on each side of the central heat exchanger One circuit board constitutes the power supply the other the audio circuitry The compact form of the Klimax case reflects our intention to keep the audio si...

Страница 10: ...heavy slow to respond inefficient causes high mains power distortion can cause electrical and acoustic noise and requires a relatively long and exposed audio path In the Klimax amplifiers we use a te...

Страница 11: ...to the value needed by the electronic circuitry and provides a safety isolation barrier from the mains supply The size of a transformer reduces as its operating frequency increases so a transformer op...

Страница 12: ...facturing process The second problem which is what stops most manufacturers considering switch mode for audio is the potential high frequency electrical noise or more precisely preventing the high fre...

Страница 13: ...filtering than ones the size of a beer can used in other very powerful amplifiers The semiconductor switches turn on and off in about 20nS 20 one thousandth millionths of a second The overload protec...

Страница 14: ...Inside the Klimax 8...

Страница 15: ...ore power and sound better than our earlier monolithic and bipolar designs So what did we choose for the Klimax Twin For several years we have been designing and building power amplifiers using monoli...

Страница 16: ...hree chips per channel and like the Klimax Solo the Klimax Twin is direct coupled with no capacitors in the signal path Combined with a slightly modified Klimax Solo power supply we have achieved as w...

Страница 17: ...y up to a very modest and calculable limit An electrical load be it a resistor capacitor inductor heater a loudspeaker or a hairdryer takes an amount of current dependent on the voltage applied to its...

Страница 18: ...simple decision making protection circuit Either the output current is safe or it s not in which case the amplifier is shut down instantly for a few seconds An unsafe output current is defined as a l...

Страница 19: ...s two methods of cooling natural convection and forced air convection Both require an ample supply of air for ventilation Natural air convection cooling operates for all normal listening conditions by...

Страница 20: ...e whatever your normal use is If you only ever listen at moderate level you may never notice the temperature rise above idling The high thermal mass of the case absorbs short periods of high power inp...

Страница 21: ...x Twin is a high fidelity music playing amplifier not an industrial servo motor drive amplifier or an arc welder Given adequate ventilation it will operate continuously in any music or AV system at an...

Страница 22: ...om the mains distortion present in the rest of the house it s to reduce how much of the mains distortion from the power amplifiers gets into the other audio components in the system Linn switch mode p...

Страница 23: ...allations to be a good compromise between sensitivity to low level signals and immunity to noise However the residual hiss level from phono preamplifiers at moderate volume settings can be enough to t...

Страница 24: ...ining of amplifiers This switch does not directly pass the audio signal but instead sends a control signal to distortionless solid state switches The standard output connectors are two Neutrik 4 conta...

Страница 25: ...ut down entirely for a few seconds and dim the light There is no half way current limiting the amplifier can either do what is required of it or it will shut down entirely The amplifier will revert to...

Страница 26: ...Vac 126VAc 200VAc 253VAc 50 60Hz Maximum input power 1000W typical operating input power 39W Standby power 18W Amplifier specification Input connectors Unbalanced switch position in WBTphono socket Ba...

Страница 27: ...uV Output connectors Standard Neutrik Optional Binding posts Output power 230W rms into 4ohms 100W rms into 8ohms Load tolerance Unconditionally stable into all loudspeaker loads Harmonic distortion 0...

Страница 28: ...so enable you to receive the Linn News and details of music available from Linn Records Warning Refer all enquiries to authorised retailers only Unauthorised servicing or dismantling of the product in...

Страница 29: ...ed Floors Road Glasgow Scotland T 44 0 141 307 7777 F 44 0 141 644 4262 UK Helpline 0500 888909 E helpline linn co uk Internet http www linn co uk America LINN Incorporated 8787 Perimeter Park Bouleva...

Страница 30: ...tors 20 Input impedance 20 Input level for clipping 21 Inputs 18 Inside the Klimax 8 Installation 13 Introduction 2 M Mains plug replacement iii Mains plugs i Mains supply 15 O Operation 19 Options an...

Отзывы: