4 PROFIdrive Parameters
4.1 Parameters
Attention:
Profinet), which can be configured with the distributed LinMot-Talk software.
With these parameters, the PROFIdrive interface can be enabled or disabled.
The LinMot-Talk software can be downloaded from
under the section download, software
& manuals.
4.1.1 PROFdrive/Dis-/Enable
With the Dis-/Enable parameter the LinMot Servo Drive can be run without the Ethernet PROFIdrive Interface
going online. So in a first step the system can be configured and run without any bus connection.
PROFIdrive/Dis-/Enable
Disable
Servo Drive runs without PROFINET.
Enable
Servo Drive runs with PROFINET connection.
IMPORTANT:
If the PROFIdrive Interface is disabled, the integrated Netx-ASIC rests in reset state! No
messages will be sent to other devices connected to the PROFINET-Network via the servo drive.
4.1.2 PROFdrive/Byte Order
With the Byte Order parameter the used Byte order of the transmitted data can be defined.
PROFIdrive/Byte Order
reversed
Byte order is reversed. For S7 PLC_s select reversed.
not reversed
Byte order is not reversed.
4.1.3 PROFdrive/Word Order
With the Word Order parameter the used Word order of the transmitted data can be defined.
PROFIdrive/Word Order
Reversed
Word order is reversed.
not reversed
Word order is not reversed.
4.1.4 PROFdrive/Monitoring Channels
With these parameters the parameters are defined which are copied to the corresponding monitoring channel.
PROFIdrive/Monitoring Channels
Channel 1 UPID
Source UPID for monitoring channel 1
Channel 2 UPID
Source UPID for monitoring channel 2
Channel 3 UPID
Source UPID for monitoring channel 3