Installation Guide Linear Rotary Motors
ENG
Page 28 / 34
PR02-88
NTI AG / LinMot
Ordering information
Item
Item
Item
Maintenance: PR01-84/PR02-88
Cleaning, replacement of wear parts
Maintenance Linear Rotary Motors
r157
8.2.1 Preventive Inspection every 6'000h
To ensure trouble-free operation, a preventive inspection is recommended every 6,000 hours of operation or
every year.
When inspecting the motors, the following points must be checked:
a) Visual inspection of all wearing parts (replace if necessary)
b) Preventive replacement of seals and wipers
c) Cleaning of mechanically moving parts
d) Replacement and maintenance of ball bearings / plain bearings, if necessary
e) Calibration of torque measuring shaft, if necessary
(The calibration of built-in torque measuring shafts is carried out at the NTI AG / LinMot factory.)
8.2.2 Inspection after each 12'000h
Maintenance is recommended every 12,000 hours of operation or every two years.
When inspecting the motors, the following points must be checked:
a) Visual inspection of all wearing parts (replace if necessary)
b) Replacement of seals and wipers
c) Preventive replacement of coupling Linear-Rotary
d) Cleaning of mechanically moving parts
e) Replacement and maintenance of ball bearings / plain bearings
f) Calibration of torque measuring shaft, if necessary
(The calibration of built-in torque measuring shafts is carried out at the NTI AG / LinMot factory.)
8.3 Calibration of Torque Measuring Shaft and Force Sensor
Sensors installed in the linear rotary motor (torque measuring shaft) are factory calibrated (valid for 2 years).
After the initial commissioning it is recommended to have the sensors calibrated annually by LinMot.
Ordering Information
Item
Description
Item-No.
Maintenance: Calibration Torque Sensor PR02
Calibration Torque Sensor PR02
0150-4163
9 Transport and Storage
•
In the case of return transport (e.g. RMA return) of the linear rotary motor, a transport
lock must be provided on the linear rotary shaft. To prevent mechanical damage, the
shaft must not move linearly during transport.
•
The storage area must be dry, dust-free, frost-free and vibration-free.
•
The relative air humidity should be less than 60 %.
•
Prescribed storage temperature: -
15 °C…70 °C
•
The motor must be protected against extreme weather conditions.
•
The air in the storage area must not contain any harmful gases.