background image

www.linksprite.com 

 

 

5

 / 

9

 

 

 

5.  Stop taking pictures 

 

Command (HEX) 

Return (HEX) 

56 00 36 01 03 

76  0 36 00 00 

 
6.  Compression Ratio  

 

Command (HEX) 

Return (HEX) 

56  0 31 05 01 01 12 04 XX  76 00 31 00 00 XX (XX normally is 36) 

 
           XX:  0X00 to 0XFF 
 

7.  Image size 

 
Command (HEX) 

Return (HEX) 

56 00 31 05 04 01 00 19 11 

320*240

  76 00 31 00 00 

56 00 31 05 04 01 00 19 00 (640*480

 

76 00 31 00 00 

56 00 31 05 04 01 00 19 22 

160*120

  76 00 31 00 00 

 
After changing the image size, it is needed to reset or power cycle. 

 

8.  Power Saving 

 

Entering Power Saving 

Command (HEX) 

Return (HEX) 

56  00 3E 03 00 01 01 

76 00 3E 00 00 

 

Exiting Power Saving 

Command (HEX) 

Return (HEX) 

56  00 3E 03 00 01 00 

76  0 3E 00 00 

 

9.  Chang baud rate  

 
Command (HEX) 

Return (HEX) 

56 00 24 03 01 XX XX 

76 00 24 00 00 

XX XX  

Data Rate 

AE C8 

9600 

56 E4 

19200 

2A F2 

38400 

1C 4C 

57600 

0D A6 

115200 

 

 
 

Содержание LS-Y201-Infrared

Страница 1: ...www linksprite com 1 9 LinkSprite JPEG Color Camera Serial UART Interface With Infrared November 2010 sales linksprite com...

Страница 2: ...red feature has a built in sensor to sense the ambient light and will automatically turn on the infrared LED 2 Specification a VGA QVGA 160 120 resolution b Support capture JPEG from serial port c Def...

Страница 3: ...www linksprite com 3 9 4 Interface definition Default baud rate is 38400 bps Name descriptions RED RXD IN Brown TXD OUT Purple GND Gray 5V DC...

Страница 4: ...JPEG file content JPEG file starts with FF D8 and ends with FF D9 To read the JPEG file always starts with address 00 00 and choose a chunk size that are an integer times of 8 and read the chunk many...

Страница 5: ...0 00 56 00 31 05 04 01 00 19 00 640 480 76 00 31 00 00 56 00 31 05 04 01 00 19 22 160 120 76 00 31 00 00 After changing the image size it is needed to reset or power cycle 8 Power Saving Entering Powe...

Страница 6: ...el is used in the module as the communication distance of raw UART cannot be longer than 1 meter 4 When powered on serial port will output the following message actively Ctrl infr exist User defined s...

Страница 7: ...www linksprite com 7 9 Capture a JPEG picture...

Страница 8: ...www linksprite com 8 9...

Страница 9: ...inksprite com 9 9 LinkSprite Technologies Inc Add 1067 S Hover St Unit E 186 Longmont CO 80501 Tel 720 204 8599 Email sales linksprite com Technical questions support linksprite com Web www linksprite...

Отзывы: