7.
Connect the Manual Control Box to the Manual
Mode Plug on the crane. Refer to the Crane Oper-
ator's Manual for the location of the connection.
8.
Push the Activate Switch up and hold. Push the
Pin/Unpin Switch up to PIN and the Latch/Unlatch
Switch down to UNLATCH.
9.
Confirm that the PINNED and NOT LATCHED lights
are illuminated. The telescope cylinder may have
to be extended or retracted slightly to obtain NOT
LATCHED.
10.
Fully retract the telescope cylinder until it bottoms
out.
11.
Press Button 3 to set the telescope cylinder zero
point.
12.
The Display should show question, “Are you sure?”
13.
Press Button 3 to confirm “Yes” or press Button 4 to
confirm “No”.
CAUTION
Manual mode is intended
only for emergency
operation.
Improper operation of the
boom in manual mode can
cause major damage to the
boom.
1.
2.
3.
4.
Extend/Retract Switch
Pin/Unpin Switch
Latch/Unlatch Switch
Not Latched Indicator Light
5.
6.
7.
Not Pinned Indicator Light
Latch Forward Indicator Light
Latch Rearward Indicator Light
8.
Pinned Indicator Light
9.
Latched Indicator Light
10. Activate Switch