The liniLED® IP40 Connector consists of: End cap
(1)
, Shell
(2)
,
Connector
(3)
, Clamp
(4)
.
Take into account the direction of the arrow on the bottom of the
liniLED® LED strip and allign it with the arrow on the clamp
(4)
.
Place the shell
(2)
over the LED strip. Make sure the side with the small-
est opening is put on first.
Side view |
Slide the clamp
(4)
over the cable to reveal the
connector
(3)
.
Slide the connector
(3)
sideways into the hollow chamber of the
liniLED® LED strip.
Side view |
Do
not
cut the PCB!
Front view |
Make sure the connector and the PCB are perfectly
horizontally alligned.
Connect
IP40
5
3
2
4
6