background image

 

 

                                                                                           

 

 

 

 

 

 

 

 

 

 

 

Basic Instruction Manual

 

Total Station LGP-300

 

series 

LGP-302N / LGP-305N 

 

TI Asahi Co., Ltd. 

Содержание LPG-300 Series

Страница 1: ...Basic Instruction Manual Total Station LGP 300 series LGP 302N LGP 305N TI Asahi Co Ltd...

Страница 2: ...2...

Страница 3: ...1 6 2 Removing and attaching the Battery 11 1 6 3 How to charge the Battery 12 1 7 USB connection 14 2 Preparation before Measurement 15 2 1 Setting up the instrument 15 2 2 Levelling Up 16 2 3 Cente...

Страница 4: ...5 1 Vertical Cross hair on Telescope 30 5 2 Horizontal Collimation Error C 32 5 3 Vertical Index Error 34 5 4 EDM Optical Axis and the Telescope Sighting Axis Error 36 6 Specifications 38 7 Standard c...

Страница 5: ...e using this product be sure that you have thoroughly read and understood this instruction manual to ensure proper operation After reading this manual be sure to keep in a convenient place for easy re...

Страница 6: ...riety of application software on it Regarding the operations of application software please refer to their respective manuals Copyright 2014 TI Asahi Co Ltd TI Asahi Co Ltd makes no warranty expressed...

Страница 7: ...ury CAUTION Items indicated by this display are precautions which if ignored may result in injury or material Here injury refers to injuries such as cuts burns or electric shock the treatment of which...

Страница 8: ...eas If this instrument is used close to industrial areas or transmitters the equipment can be influenced by electromagnetic fields Do not use this product in a coal mine in a location where there is c...

Страница 9: ...circuit when removing the battery and charger from the case and storing them apply electrically resistant tape to the poles of the battery Storing the battery and charger as is may result in fire or...

Страница 10: ...echanism of the instrument so as not to emit the laser beam at the time of disposal Do not remove the handgrip without good reason If it does come off be sure to attach it securely to the instrument w...

Страница 11: ...son as the person may be injured if they strike him or her The instrument contains a rechargeable battery and it is rechargeable At the end of its useful life it may be illegal to dispose of the batte...

Страница 12: ...or solar observation be sure to attach the special solar filter designed for this product to the objective lens Laser beam Do not stare into laser beam LGP 300N series is a Class IIIa 3R laser product...

Страница 13: ...instrument cannot calculate correctly when receiving reflected laser beam from forth and back directions in case of measuring the target on the road There is a possibility that synthesized values are...

Страница 14: ...the time a battery lasts on one charge differs depending on conditions of ambient temperature and the measurement mode of the instrument Confirm the battery level remaining before operating When the r...

Страница 15: ...13 Touch panel Use the Stylus pen when you touch the panel for operation of software Do not touch the panel with any things such as fingertips or pen point as this may scratch and damage the screen...

Страница 16: ...ore use Be sure to protect the instrument from the sun if the location is subject to intense direct sunlight During surveys for which the survey precision or atmospheric measurement method has been de...

Страница 17: ...ument battery or charger even if you do detect an abnormality as there is a risk of fire or electric shock due to short circuit If you think the product requires repair contact the retail outlet where...

Страница 18: ...1 1 Functions 1 1 Names of the parts Top handle Optical sight Touch screen Keypad Handle screw Instrument height mark Objective Lens Stylus pen Circular level...

Страница 19: ...2 Plate level Horizontal clamp knob USB port Tribrach clamp Eyepiece Vertical tangent knob Vertical clamp knob Horizontal tangent knob Battery clamp...

Страница 20: ...cil or other sharp thing to avoid damage on instrument Keys Name Functions 0 9 A Alphanumeric keypad Enter text and numerical values Shift key for character entry The current entry method can shift am...

Страница 21: ...entry or selection ESC Escape key Quit a screen or edit mode without saving changes Return next higher level FUNC Function key Perform variable functions defined by program screen Navigation key Contr...

Страница 22: ...duction Display After initiating the instrument the screen will go to present Welcome Interface which is shown right Main Menu consists of FieldGenius INST Setup Instrument Setup and About Relevant In...

Страница 23: ...constant It is made up of a series of functions such as compensator linear correction compensator zero correction horizontal axis error correction index correction instrument settings distance consta...

Страница 24: ...pressing FieldGenius icon you can start up professional surveying and cartography program MICROSURVEY FieldGenius For the operation of FieldGenius visit FieldGenius http www microsurvey com products f...

Страница 25: ...be changed anytime in middle of work 1 4 Shortcut key 1 The following is the list of shortcut keys available for LGP 300 Series Key combination Description Power on off Enter into setting mode direct...

Страница 26: ...ys will be changed The inputting method will be display on the lower right corner 1 5 Touch screen calibration When you operate on the screen if your device isn t responding to you taps you may need t...

Страница 27: ...Power indicator At any screen press key to open the Quick Setting Menu Select Battery battery level will be seen following Battery Level NOTE 1 The battery s working time will be affected by many fact...

Страница 28: ...ement mode from angle mode the power maybe auto off because of lower battery 3 The symbol only indicates the supply power but not the instantaneous power change And if the measurement mode changes the...

Страница 29: ...the protrusion of the instrument and push the battery pack down into place 1 6 3 How to charge the Battery The LGP 300 comes with two lithium ion rechargeable batteries with a typical operating time b...

Страница 30: ...ns grenn Place your battery in charger bay correctly and make sure LED turns red Wait until battery LED indicator turns GREEN for a full charge LED Description NONE AC cord or AC adapter is not correc...

Страница 31: ...could be used by USB Host connector The file in the external memory stick could be read in the instrument interface 1 Open the cover of USB which behind the display panel 2 Input external memory stick...

Страница 32: ...at equal intervals and the head is approximately level Set the tripod so that the head is positioned over the surveying point Make sure the tripod shoes are firmly fixed in the ground 2 Attaching the...

Страница 33: ...ndicates the movement of the circular bubble 2 Move the bubble to the center of the circle by turning screw C 2 Accurate Levelling Up with plate level 1 Loosen the horizontal motion clamp and turn the...

Страница 34: ...nient for LGP 300N series to level up with electronic level especially when it is difficult to observe the circular level and plate level Firstly press the key to turn on the electronic bubble as show...

Страница 35: ...gure you can realize transformation of compensation options by pressing the lower right button XYON compensate horizontal angle and vertical angle at the same time XONYOFF just compensate X axis XYOFF...

Страница 36: ...that laser emits downwards can be seen Loosen the center screw of tripod and move the base plate on tripod head until the laser spot coincides with ground mark point Then tighten the center screw Repe...

Страница 37: ...nstant settings communication port settings configuration management etc 3 1 INST Setup Enter instrument settings program by clicking INST Setup icon on the Main Menu And then input the password 12345...

Страница 38: ...142 K 0 2 No 5 Sea Level correction mode will be Yes or No 6 Target Type mode will be Prism No Prism Reflector You could press Enter to keep the setting or press cancelled 3 1 2 Setting the units Oper...

Страница 39: ...on ports As left figure shows click Other Setup you can activate bluetooth BT and guidelight GL and set parameters of Bluetooth Port and Phy Port 3 1 4 Instrument parameters review Click Data Monitor...

Страница 40: ...ys in order to go on with illumination settings including Cross Light and Laser Point Cross Light Click this item to turn on the reticle illumination and move the slipping button to adjust reticle ill...

Страница 41: ...24 4 3 About Instrument firmware version is shown here Operation 1 Click About icon on desktop 2 Press Exit to return the basic measurement...

Страница 42: ...roximately horizontal line AC with about 100 meters long Measure the distances of lines AB AC and BC 2 The instrument constant can be calculated Instrument constant AB BC AC 3 If there is a difference...

Страница 43: ...26 2 Adjustment About instrument constant setting you must contact LINERTEC distributor to do that...

Страница 44: ...the bubble if it is still centered no adjustment is necessary if not you have to adjust it 2 Adjustment 1 Mount the instrument on a stable device and fix it 2 Level it roughly 3 Turn the instrument a...

Страница 45: ...device and fix it 5 Level it accurately by the plate level 6 Adjust the three adjusting screws to center the bubble by a wrench Note Be careful when adjusting the three screws and the tightening tensi...

Страница 46: ...tor then fix the two screws again 4 4 Laser Plummet 1 Check 1 Set the instrument on the tripod and place a piece of white paper with a cross drawn on it right under the instrument 2 Move the paper so...

Страница 47: ...al Cross hair on Telescope 1 Check 1 Set the instrument up the tripod and carefully level it 2 Set a point A front the instrument 50m apart 3 Collimate the point A and adjust the vertical tangent scre...

Страница 48: ...oint A finally re tighten the four screws 5 Repeat the checking and adjusting until there is no deviation NOTE 1 After the adjustment of cross hair please check the collimation error and vertical inde...

Страница 49: ...t on tripod or adjustment platform and leveling accurately 2 Aim at the cross hairs of collimator or the obvious target at a distance Get the face left angle reading H1 and the face right angle readin...

Страница 50: ...adjustment can be performed by the program when C 30 if C 30 adjust the reticle Reticle Adjusting 1 Rotate the instrument in face right position turning horizontal tangent screw until Hr Hr C 2 Loosen...

Страница 51: ...sure to read manual carefully otherwise it may cause data faulty Because of the close relationship between vertical index and compensator zero position it is necessary to check and adjust compensator...

Страница 52: ...error and vertical index error setting menu 2 Aim at the cross hair of collimator at telescope left tap Left value to read the horizontal and vertical angles 3 Aim at the cross hair of collimator at...

Страница 53: ...Aim at the prism center with telescope reticle 4 Enter EDM signal testing screen 5 Observe through eyepiece turn the focusing knob until the red mark is clear if the deviation between mark and cross...

Страница 54: ...bserve the laser spot if the laser spot coincides with the cross mark of reflective sheet adjustment is unnecessary NOTE Laser radiation do not stare into beam 3 Adjustment If the instrument needs adj...

Страница 55: ...1200m Prism 1P 3000m Accuracy 4 Prism 2 2ppm x D mm Reflector Sheet 3 2ppm x D mm Reflectorless 2 150m 3 2ppm x D mm 150 300m 5 2ppm x D mm 300 500m 10 2ppm x D mm Angle measurement Measuring method...

Страница 56: ...B mini Bluetooth Class 2 USB Flash Drive Display Keyboard Display type 3 5 colour TFT LCD 320 x 240 dots touch screen Quantity 2 Keys 26 each Display back light Yes Laser Pointer Yes Date clock Yes Sp...

Страница 57: ...00m in prism mode and 300m in reflectorless mode 7 Standard components Carrying case 1 each Instrument 1 each Battery 2 each Charger 1 each AC Adapter 1 each Power Cable 1 each Adjusting pins 1 each S...

Страница 58: ...hPa t Temperature value Kpt Atmospheric correction ppm Example t 20 p 1013hpa L0 1000m Then Kpt 0ppm L L0 1 Kpt 1000 1 0 10 6 1000 000m The atmospheric value is obtained easily with the atmospheric c...

Страница 59: ...42...

Страница 60: ...curvature for distance measurement the formula for slope distance horizontal distance and vertical distance applied in the instrument are as followings The conversion formula for horizontal and vertic...

Страница 61: ...coefficient K is 0 142 Refer to the section 3 10 to change the value of K NOTE These designs figures and specifications are subject to change without notice We shall not be held liable for damages re...

Страница 62: ...eling Aperture label Warning logotype For North America Certification Aperture label Laser beam is transmitted from this aperture Warning logotype Laser beam is transmitted from this aperture Warning...

Страница 63: ...46...

Страница 64: ...47 TI Asahi Co Ltd International Sales Department 4 3 4 Ueno Iwatsuki Ku Saitama Shi Saitama 339 0073 Japan Tel 81 48 793 0118 Fax 81 48 793 0128 E mail international tiasahi com LGP300150101...