Page 3 from 3
INSTALLATION PROCEDURE (For wall mounting only)
1. Use the supplied mounting accessories to mount the device (Fig1).
2.
Remove the four cover retaining screws
(
Fig
1
)
.
3. Install the battery cable connectors to the batteries taking care of the polarity, black cable (-)
and red cable (+).
4.
Always use in any case round mains cable
,
with external diameter
of
6-9
mm (H05RN-F
type 2x1mm² or any other type, at least equal to it’s mechanical and electrical
properties). ATTENTION!! The cable must not be deformed in any way (This
requirement is important to ensure the tightness isolation IP65).
Install
the cable gland
,
pass the round cable through and tighten it all the way.
5. Connect the cables to the respective positions in the terminal block
L for phase and N for
neutral
.
6
.
Reinstall the front cover and fasten the retaining screws. (Tightening torque
1
Nm
).
Pay attention to the 4 sealing o-rings.
WARNING!!
After the installation has finished, charge the batteries for at least 24 hours so as to
obtain the rated autonomy duration
.
Page 2 from 3
case of less time than the minimum
autonomy duration the batteries must be
replaced. If the measured time is
considerably less than the minimum
autonomy duration
contact the installer.
The replacement of the battery and the
light source must be done using parts of
the same type, by the manufacturer or by a
competent person.
5.
In case of inactive use for a period greater
than 2 months, disconnect the battery by
pulling out the battery’s connector.
6.
I
s not allowed to discard batteries in
t i
to common trash bins, they must be
discarded only
in battery recycling
points. Do not incinerate.
Battery replacement
It can be done only by a competent person
and after the mains interruption.
1.
Follow the step 2
of the installation
procedure.
2.
Disconnect the
cables and remove the old
battery.
3.
Connect the new battery with the same type
(step 3 of the installation procedure) and
place it in the position of the old one.
4.
Follow the step
6 of the installation
procedure and power the device.
(*) Non Maintained operation: The luminaire lights
its illumination source, only in power supply’s
failure.
Maintained operation: The luminaire lights its
illumination source, when it is powered by the
mains power supply or not
.
NOTE:
LED= Light Emitting Diode
LABELING EXPLANATION:
X:
Self contained
0:
Non Maintained (*)
A:
Including test device
90:
1.5 hour duration
18
0:
3 hours duration
The light source contained in this luminaire shall only be replaced by the manufacturer, or
his agent, or a similar qualified person.
NOTE! The light source is non-user replaceable.
INDICATION LED STATUS (with the mains power supply connected
)
CHARGE
POWER
Disconnected battery
/
not charging
Charged battery
Normal operation mode
No mains power supply
Indicator ON
Indicator OFF
LED CHARACTERISTICS
Linergy s.r.l
.
Cable connection between main pcb and led module
Manufacturer
Model Number
Voltage Range
Connections
Nominal Power
Temperature (tc
)
DU239P13EGS
DU239P30EGS
68 °C max.
17.5-20.5V
14W
1005183
TEST
button
Fig
.
1
Power
indicator
Mounting holes
Charge
indicator
Cover
retaining
screws
4
L
N
3
ISTDUALLED_V2-R2
ISTDUALLED_V2-R2