background image

Interface Converter

Instruction Manual

3 rd

The CD-ROM attached to a product contains the newest English and Japanese 

instruction manuals in a PDF format. Please also refer to them.

LAN 

 RS-422/485

 

 

SI-65

 

 

SI-65A

 

 

SI-65A-L

 

 

SI-65FA

 

 

SI-65FA-L

Содержание SI-65

Страница 1: ...er Instruction Manual 3 rd The CD ROM attached to a product contains the newest English and Japanese instruction manuals in a PDF format Please also refer to them LAN RS 422 485 SI 65 SI 65A SI 65A L...

Страница 2: ...have any questions feel free to direct your inquiries to LINEEYE LINEEYE makes no warranty or guarantee either expressed or implied with respect to its quality performance merchantability or fitness...

Страница 3: ...und emanates from itself Continuous use may cause a burn fire or electric shock Keep the products dry Keep them away from water Failure to do so may cause overheating an electric shock or unit malfunc...

Страница 4: ...y damaging a cord Please do not damage the power cable by pulling stamping or tearing This may result in a injury an electric shock fire explosion and or a breakdown due to overheating Do not place th...

Страница 5: ...ress 21 Chapter 4 Configuration Using Web Manager 22 4 1 Web Manager Usage 22 4 2 Communication conditions of serial port 24 4 3 Set up LAN connection mode 24 4 4 Other Setting 25 Chapter 5 Setup Exam...

Страница 6: ...5 SI 65A and SI 65FA Description of I O pins on the XPort The description of I O pins of XPort at configuration differs depending on the version of the WEB manager And the version of the WEB manager a...

Страница 7: ...None Stop 1 or 2 Flow Control Xon off Line Monitoring LED Display SD SD RD DRIVER ACTIVE Isolation Photo coupler Signal part Isolation transformer Power source part Surge Protection 15KV ESD L A N In...

Страница 8: ...en it receives data from serial side it transmits the data by putting it on the data part of the TCP IP or UDP IP packet When it receives data from the Ethernet side it extracts the data part of the T...

Страница 9: ...ermits to send data from the converter to the RS 485 circuit This function allows the flow control to operate in a direction of sending only The flow control in a direction of receiving does not opera...

Страница 10: ...Signal Grand 4 6 5V IN External Power Input 5 External Power Input 5 1 Can switch by the dip switch 2 Out means a direction to output signals from the converter In means a direction to input signals t...

Страница 11: ...block Press to screw type Standard Torque 0 25Nm M3 2 6 9 Rubber foot Rubber foot to place the unit horizontally 7 6 1 Pin assignment of RS 422 485 terminal block Terminal No Name Full Duplex Mode 1 H...

Страница 12: ...SI 65FA wall hanging model Model number SI 65FA L SI 65FA and SI 65FA L have same function About the detail of the shape of SI 65FA L please refer to Attach on the wall For SI 65FA L at 7 8 Installati...

Страница 13: ...ard Torque 0 25Nm Screw size M3 2 6 9 Rubber foot Rubber foot to place the unit horizontally 7 6 1 Power terminal block Terminal Name Description AC IN Power terminal AC85 264V 50 60Hz FG Terminal for...

Страница 14: ...nal timer is accurate at 10 to 10 SW A No 4 Driver Control Selects two kinds of control methods in the RS 422 485 driver control line of the converter active and auto SW A Meaning OFF ON No 4 RS 422 4...

Страница 15: ...No 2 Echo Back Setup Selects the echo back specification for the half duplex RS 485 mode OFF Echo Back Echo back the data which is sent from the converter to the RS 485 line The full duplex RS 422 mod...

Страница 16: ...taB Send and Recive DataA GND SG SD SD SD RD SD RD GND SI 65 A FA Target Device RS 485 half duplex Setting SD SD SD RD SD RD GND SI 65 A FA Target Device RS 422 full duplex Setting Receive RDB Receive...

Страница 17: ...n the case of SI 65 1 Prepare DC source of 5 12V DC 5 9V is recommended 4W or more Current consumption of SI 65 is up to 300mA regardless of supply voltage External source of lower voltage is recommen...

Страница 18: ...ply on the cable then open the cover of terminal block and connect the cables 3 Connect the external AC power source to the AC IN of the terminal and the grounding wire to the FG terminal Please use a...

Страница 19: ...owing procedure Set through network using Web browser Input the IP address in the Web browser of the PC and set from the Web manager Refer to Chapter 4 Use set up mode Connect the converter by Telnet...

Страница 20: ...ler of Lantronix for setting the IP address Preparation Log to the PC as administrator If you had already installed the previous version of DeviceInstaller uninstall it If you would like to use the co...

Страница 21: ...the network and turn on the power 2 Open the DeviceInstaller from Start menu 3 Device embedded with XPort is displayed on the main window 4 Select the one matched with the hardware MAC address and co...

Страница 22: ...line help of DeviceInstaller for appropriate use of DeviceInstaller Note IP address can be set using the set up mode Refer to Xport User Guide XPort_UG pdf in the CD ROM IP address can be set using th...

Страница 23: ...d password enter nothing and click OK Accessing from the web browser Open your web browser and enter the IP address Then you will be required to enter the user name and the password If you have not se...

Страница 24: ...ve and apply the configuration changes to the device server click the Apply Settings button The Apply Settings button makes the changes permanent and reboots the XPort If you change the IP address on...

Страница 25: ...ho back and line monitoring function Please set CTS RTS Hardware at Flow Control when you use the line monitoring function Note 3 Click OK and then click Apply Settings 4 3 Set up LAN connection mode...

Страница 26: ...e reaches to the Maximum Transmission Unit MTU default 1400 bytes a transmission might occur even if the packets are not satisfy the condition Disconnect TCP Select Channel 1 Connection and set Discon...

Страница 27: ...the menu and set the communication condition Press OK after setting the values LAN connection mode Server mode valid Client mode invalid Select Connection at the menu and set YES at Accept Incoming P...

Страница 28: ...ettings at the menu and set the communication condition Press OK after setting the values LAN connection mode Server mode invalid Client mode valid Select Connection at the menu and select With Any Ch...

Страница 29: ...al Settings at the menu and set the communication condition Press OK after setting the values Set a specific IP address to the converter 2 Assign by the proper method concerning the usage and environm...

Страница 30: ...th Any Character at Active Connect Then set the IP address of the converter 1 to Remote Host and port number of the converter 1 to Remote Port Press OK after setting the values Converter 2 Press Apply...

Страница 31: ...t to install the COM Port Redirector to PCs which have already installed such software Note 6 2 Basic Setting Depending on the target devices setup of the serial port and virtual COM port condition is...

Страница 32: ...g box check the COM port you wish to use as the virtual COM port 4 In the Settings tab there is a host list table Set the IP address and port number at Host and TCP Port in the Service1 Click Search F...

Страница 33: ...properly please use the manual and the tools contained in the CD ROM which comes with the product XPort 05 firmware in not compatible with the firmware of XPort 03 04 For more details refer to the we...

Страница 34: ...at 3 This model if for customers who purchase several units Utility CD manual and AC adapter are not provided Configuration tools stored in the utility CD are available from web page 7 4 LAN Connector...

Страница 35: ...active 7 6 Factory setting RS 232C Condition Protocol RS 232 Do not change Speed 9600bps 8bit Parity None Stop 1bit Flow Control None LAN Action Mode Accept Incoming Yes Server Mode Enable Active Conn...

Страница 36: ...change This method cannot reset the password Operation of SILANIOinit configuration tool 1 Copy SILANIOinit exe from the LINEEYE SILANIOinit folder in the utility CD to the appropriate folder For exa...

Страница 37: ...de wizard step 3 5 will appear Select Install setup records from a file and click Browse 8 Open the configuration file in the appropriate folder For example c setup Click Next 9 Device upgrade wizard...

Страница 38: ...65FA it is possible to screw from the front of the device after inserting the L bracket on the side Does not support SI 65FA L 80 102 122 60 Optional L bracket SI ML1 fitting condition DIN rail You c...

Страница 39: ...ws or nails hammered into the wall Wall bracket SI WM1 Two 3 2 holes are for attaching this bracket on the backside of the converter other holes on each side of the bracket are for attaching on the wa...

Страница 40: ...stance The faster communication speed is the shorter the transfer distance for RS 422 485 is See the right table and set communication speed following the actual distance Also the maximum of the actua...

Страница 41: ...se the cross over LAN cable Cannot find in the Deviceinstaller Is the converter connected to the same network segment with PC Can not search if the converter connected to the different network segment...

Страница 42: ...485 port side Are SD RD LEDs blinking It is working correctly if the LEDs are blinking when the data was transmitted on the RS 422 485 line Note This can be difficult to distinguish when the transmit...

Страница 43: ...ical stress misuses abuse negligence or accidents LINEEYE disclaims all other warranties including the warranties of merchantability fitness for some particular purposes and noninfringement of third p...

Страница 44: ...075 693 0163 URL http www lineeye com Email info lineeye co jp Printed in Japan M 3665AFAE SI LINEEYE CO LTD There is a registration page on our web site http www lineeye com Please register your prod...