37
7-8. Installation Method
Set in the stable place
Rubber feet are put on the bottom of the device. Please set it on a flat and stable place.
*
Please place it as far away from high voltage equipments or power equipments as
possible.
Using screws
There are four M3 screw holes on the back of converter.
Use M3 screw, which can be inserted into the converter less than 7mm depth from the
top of the case. If the depth is deeper than that, it will damage the main circuit.
Note
Screw holes on backside (SI-65/SI-65A)
M3 screw holes
LAN
Connecter
L bracket (SI-ML1)
For SI-65FA, it is possible to screw from the
front of the device after inserting the L bracket
on the side. (Does not support SI-65FA-L)
80
102
122
60
Optional L bracket (SI-ML1) fitting condition
DIN rail
You can attach it to a 35mm DIN rail by using SI-DIN70 (optional) for SI-65/SI-65A or SI-
DIN10 (optional) for SI-65FA. (SI-65FA-L does not support attachment to din rail.)
1. For SI-65/SI-65A, screw DIN rail mounting
plate (SI-DIN70) to M3 screw halls on the
bottom of the product.
For SI-65FA, screw DIN rail mounting plate
(SI-DIN10) to M3 screw halls on the side of
the product.
DIN rail mounting plate (SI-DIN70)
2. Insert it by pushing it into the DIN rail from
the front side of the rail.
3. To remove the plate from the DIN rail, pull
up the knob using the screwdriver etc.
112